Search Results: 2022

Showing 941 - 950 of 974 results

Display results per page.
  • Media type icon

    PART-SVX008A-EN-EN_09302025

    Document Title:TruSense™ Refrigerant Monitor
    Publication Type:Installation Operation and Maintenance
    Publication Date:2024-09-30
    Supersedes RMWH-SVX001D-EN (June 2022) ©2025 Trane General Information Description Identifying Your Unit Visible Alarming Devices Touchscreen Display Strobe Audible Alarming Devices Internal Horn Optional External Horn Optional External Alarm Activation and Silencing Stations Communications Digital
  • Media type icon

    RT-SVX070C-EN_05302023

    Document Title:Packaged Rooftop Air Conditioners, Precedent™ Cooling and Electric Heat, Standard Efficiency 6 to 25 Tons - 60 Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2023-05-30
    (September 2022) ©2023 Model Number Description General Information Unit Inspection Exterior Inspection Inspection for Concealed Damage Unit Storage Unit Description Door Handles Unit Nameplate Compressor Nameplate Microchannel Coil Barcode ID LonTalk Communication Interface (Optional) BACnet
  • Media type icon

    RT-PRC091F-EN_09152023

    ortranetechnologies.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. Weare committed to using environmentally conscious print practices. RT-PRC091F-EN 15 Sep 2023 Supersedes RT-PRC091E-EN (November 2022) ©2023 Trane
  • Media type icon

    RTAF-SVX001N-EN_03212025

    2583 2110 2581 2108 2579 2106 2577 - - 450 2087 2969 2064 2936 2042 2896 2011 2868 1982 2820 1954 2783 500 2192 2992 2172 2963 2153 2928 2126 2903 2100 2862 2076 2829 575V Units(b) 115 1596 1997 1592 1993 1587 1490 - - - - - - 130 1618 2022 1612 2013 1603 1501 - - - - - - 150 2447 2818 1845 2123 1391
  • Media type icon

    WSHP-PRC034B-EN_06302025

    stringent than UL 60335-2-40 requirements. See Refrigeration Systems and Machinery RoomsApplication Considerations for Compliance with ASHRAE® Standard 15-2022 Application Engineering Manual (APP-APM001*-EN) for more information. Application Considerations WSHP-PRC034B-EN 25 Minimum Room Area Limits
  • Media type icon

    BAS-SVP054B-EN_09222023

    Document Title:BACnet Communication Interface (BCI2-I) for IntelliPak and Commercial Self-contained
    Publication Type:Integration Guide
    Publication Date:2023-09-22
    ortranetechnologies.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. Weare committed to using environmentally conscious print practices. BAS-SVP054B-EN 22 Sep 2023 Supersedes BAS-SVP054A-EN (April 2022) ©2023 Trane
  • Media type icon

    BAS-SVX60C-EN_12012022

    Document Title:Instruction Manual
    Publication Type:Installation Operation and Maintenance
    Publication Date:2022-12-01
    BAS-SVX60C-EN_FrontCover_12012022.pdf Instruction Manual December 2022 BAS-SVX60C-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires
  • Media type icon

    RT-PRC111B-EN_08232024

    Document Title:Packaged Rooftop Air Conditioners Foundation™ Cooling and Gas/Electric
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2024-08-23
    requirements of ASHRAE 90.1-2022. Easy Access Low Voltage Terminal BoardThe Foundation™ low voltage terminal board is mounted outside the main electrical control cabinet.Save time by attaching the thermostat control wiring and testing operation of all unit functions. Fan Failure SwitchIn electric
  • Media type icon

    RT-PRC117B-EN_12132024

    Document Title:Precedent™ Packaged Rooftop Units
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2024-12-13
    evaluated.Depending on the application, a specific requirement of ANSI/ASHRAE Standard 15, Safety Standardfor Refrigeration Systems, could be more stringent than UL 60335-2-40 requirements. See RefrigerationSystems and Machinery Rooms Application Considerations for Compliance with ASHRAE® Standard15-2022
  • Media type icon

    BCX-PRC003C-EN_12052025

    Document Title:Blower Coil Air Handler
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-12-05
    60335-2-40 requirements. See Refrigeration Systems and Machinery RoomsApplication Considerations for Compliance with ASHRAE® Standard 15-2022 Application Engineering Manual (APP-APM001*-EN) for more information. Leak Detection System(Refrigerant charge greater than 3.91 lb of R-454B or 4.04 lb of R