Search Results: 18-HE125D1-1C-EN

Showing 971 - 980 of 7,117 results

Display results per page.
  • Media type icon

    5732-2801E_10142024

    Document Title:Unit Field Wiring ACSA - ACXA / Wiring Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-10-14
    A WIRE RANGE OF 14 TO 18 AWG OR TO DIN RAIL MOUNTED SPRING FORCE TERMINALS. 12 CONTACT RATINGS AND REQUIREMENTS:UNIT PROVIDED DRY CONTACTS FOR THE CONDENSER / CHILLED WATER PUMP CONTROL. RELAY CONTACT RATINGS AT120VAC: 7.2A RESISTIVE, 2.88A PILOT DUTY, OR 1/3 HP, 7.2 FLA. CONTACTS ARE RATED FOR
  • Media type icon

    RT-PRC117B-EN_12132024

    Document Title:Precedent™ Packaged Rooftop Units
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2024-12-13
    Knockdown Curb FIACURB403* 14-inch Full Perimeter Knockdown Curb FIACURB404* 14-inch Full Perimeter Knockdown Curb Features and Benefits 8 RT-PRC117B-EN Table 4. Accessories (continued) FIA KIT DESCRIPTION FIACURB801* 18-inch Full Perimeter Knockdown Curb FIACURB802* 18-inch Full Perimeter Knockdown
  • Media type icon

    FNR-PSD015A-EN_07012025

    for A801X with single stage AC or heat pump with two stage airflow FNR-PSD015A-EN 17 Dimensional DataFigure 5. 14.5-inch, 17.5-inch, 21-inch and 24.5-inch width cabinets 18 FNR-PSD015A-EN Notes FNR-PSD015A-EN 19 Notes About Trane and American Standard Heating and Air ConditioningTrane and American
  • Media type icon

    COR-SVN005B-EN_11302025

    Document Title:High Efficiency Horizontal, Flat “Cased” Coils, 5PXFH AZ Models
    Publication Type:Installation
    Publication Date:2025-11-30
    "To Outdoor" flag label should bespliced to field provided outdoor wire within the furnacecabinet. Wiring 18 COR-SVN005B-EN Field WiringFigure 11. 24V field wiring diagram for heating thermostat plus AC/HP COR-SVN005B-EN 19 Figure 12. AccuClean or CleanEffects air cleaner plus 24V vac furnace
  • Media type icon

    TD-PRC007A-EN_12062024

    area size Table 2. 2-inch pipe flow thermal area Fluid Velocity (FPS) Fluid Flow (GPM)Thermal Area Cooling Tons for 35% EG Fluid ∆T(a) ∆T = 6°F ∆T = 10°F ∆T = 15°F ∆T = 20°F 2.5 25 6 9 14 18 5 49 11 18 27 36 7.5 74 16 27 41 54 (a) Fluid flow and thermal area size TD-PRC007A-EN 9 Table3. Pressure
  • Media type icon

    ACC-SVN319A-EN_01122025

    Document Title:0 to 100% Standard Economizer – Foundation™ Packaged Rooftop Units Cooling and Gas/Electric 7.5 to 12.5 Tons
    Publication Type:Installation
    Publication Date:2025-01-12
    , adjusted or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. January 2025 ACC-SVN319A-EN Installation Instructions0 to
  • Media type icon

    12134657_B_02202023

    Document Title:IPAK 2 POWER SCHEMATIC 90-150T REFRIGERATION POWER VARIABLE SPEED
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-20
    - COMPRESSOR 2A 802M5 MOTOR - COMPRESSOR 2B 832M6 MOTOR - CONDENSER FAN 1A 912M7 MOTOR - CONDENSER FAN 1B 952M8 MOTOR - CONDENSER FAN 1C 982M9 MOTOR - CONDENSER FAN 2A 912M10 MOTOR - CONDENSER FAN 2B 942M11 MOTOR - CONDENSER FAN 2C 982M21 MOTOR - CONDENSER FAN 1D 1012M24 MOTOR - CONDENSER FAN 2D 1012M27
  • Media type icon

    ABS-SVN01A-EN_08012003

    Document Title:Installation - Single-Stage Absorption Chiller with Microprocessor Control Panel. Unit Models ABSC-01B-04F
    Publication Type:Installation
    Publication Date:2003-08-01
    module and1U5 starter module. Figure 18. 1U1, 1U3 and 1U5 field connection points 35ABS-SVN01A-EN Chart 8 identifies the field wiringconnection points for connectingfield devices to the unit controlpanel. Each item is discussed in thefollowing text. General External Wiring Required Chilled Water Flow
  • Media type icon

    12134689_B_02202023

    Document Title:COMPONENT LAYOUT; FUSE REPLACEMENT TABLES
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-20
    Fuse-ID Size Type1F19 (x3) 0.5A Class CC Time Delay Device-ID Description Address4TB1 Supply Fan VFD 74TB3 Compressor VFD 36TB6 Relief Fan VFD 96TB6 Return Fan VFD 122M6 Condenser Fan 1A 312M7 Condenser Fan 1B 322M8 Condenser Fan 1C 33 2M21 Condenser Fan 1D 342M9 Condenser Fan 2A 40 2M10 Condenser
  • Media type icon

    VRF-SLB019-EN_06012018

    Document Title:Mitsiuishi Electric - Commercial Heating and Cooling Solutions
    Publication Type:Sales Brochure
    Publication Date:2018-06-01
    -NAMU-E 12, 18, 24, 30, 36, 48, 54 Concealed-ducted Vertical/Horizontal Air Handler Nominal Btu/h: 12,000 - 54,000 VRF-SLB019-EN | 06.2018 ©2018 Mitsubishi Electric Trane US HVAC, LLC. All rights reserved. Mitsubishi Electric, Lossnay, and the three-diamond logo are trademarks of Mitsubishi Electric