Search Results: 18-HE125D1-1C-EN

Showing 881 - 890 of 7,117 results

Display results per page.
  • Media type icon

    RT-PRC060N-EN_12032022

    standard.(b) Optional field-installed MERV 13 filters available.(c) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 18 RT-PRC060N-EN Table 2. General data — heating performance – 15 to 25 tonsHeating Performance 15 Tons 17.5 Tons(a
  • Media type icon

    BAS-PTS038B-EN_09262025

    Document Title:Symbio™ 500 Integration Point List BACnet® Self-Contaned (SWUD*)
    Publication Type:Points List
    Publication Date:2025-09-26
    Units Read [1, Auto] [1, Auto] [2, Heat] [3, Morning Warm-up] [4, Cool] [5, Night Purge] [6, Pre Cool] [7, Off] [8, Test] [9, Emergency Heat] [10, Fan Only] [11, Free Cool] [12, Ice-Making] [13, Maximum Heat] [14, Economizer] [15, Dehumidify] [16, Calibrate] BAS-PTS038B-EN Multi-State Values 18 Symbio™
  • Media type icon

    ACC-SVN322A-EN_01122025

    Document Title:Vertical and Horizontal Power Foundation™ Packaged Rooftop Units Cooling and Gas/Electric 7.5 to 12.5 Tons 208/230V Single Phase, 460V Three Phase
    Publication Type:Installation
    Publication Date:2025-01-12
    , adjusted or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. January 2025 ACC-SVN322A-EN Installation
  • Media type icon

    VAV-PRC012AF-EN_11152025

    flow. The disadvantage of the parallel unit isintermittent sound. This impact can be minimized by using an ECM, which has slow fan ramp-up speed and can be configuredfor variable-speed fan control. Application Considerations 18 VAV-PRC012AF-EN The primary acoustic benefit of a series fan-powered unit
  • Media type icon

    CLCH-PRC032D-EN_12012025

    -EN 7 Digit 17 — Electric Heat/Factory MountedOnly0 = No electric heat1 = Electric heat with 1 stage2 = Electric heat with 2 stages4 = Electric heat with 4 stages5 = Electric heat with SCR ControlS = Special Digit 18, 19, 20 — Electric Heat KW 000 = No electric heat006 = 6.0 kW007 = 7.0 kW008 = 8.0
  • Media type icon

    ODR-SVX030A-EN_03202026

    Service Facts shipped in the outdoor unit for moreinformation.Pin Identification on J5 (See Figure 27, p. 18)1. TEST_COMMON (Shorting to FRC_DFTcauses the control to initiate Forced Defrost. Leaving this pin openresults in the normal mode of operation.) Electrical 18 ODR-SVX030A-EN 2. FRC_DFT = Forced
  • Media type icon

    PKG-PRC023B-EN_04242020

    Document Title:Commercial Self Contained Plenum Supply Fan SCWF High Capacity 25-72, 80 Ton
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2020-04-24
    [replace with document title] Product Specifications Commercial Self ContainedPlenum Supply FanSCWF High Capacity 25-72, 80 Ton © 2020 Trane April 2020 PKG-PRC023B-EN Mechanical Specifications The supply fan shall be a single width/single inlet, 12-bladed plenumfan. Fan blades shall be backward
  • Media type icon

    SO-SVN036B-EN_12132024

    Document Title:CVRF - Symbio™ 800 Chiller Controller Retrofit Replacement Panel UCP2
    Publication Type:Installation
    Publication Date:2024-12-13
    Damage!Failure to follow instruction below could result in equipment damage. Never route low-voltage leads with other conductors carrying 30 or more volts. Installation 18 SO-SVN036B-EN bypass or Enhanced Protection packages were ordered and are to be installed. 8. Bearing temperature sensors: inboard
  • Media type icon

    RT-PRC053L-EN_12202022

    Document Title:Packaged Rooftop Air Conditioners Precedent™ with eFlex™ Technology — Cooling and Gas/Electric 3 to 10 Tons — 60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2022-12-20
    standardized across the board, ensuring a lower cost to owners. 18 RT-PRC053L-EN Application Considerations Application of this product should be within the cataloged airflow and cooling considerations. Barometric Relief This product line offers an optional barometric relief damper for use in
  • Media type icon

    PKGP-PRC021D-EN_09302023

    Document Title:Packaged Rooftop Air Conditioners Precedent™ Heat Pump High Efficiency 12.5 to 25 Tons — 60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2023-09-30
    = Stainless Steel Drain Pan Digit 28— Short Circuit Current Rating 0 = Standard (5k) SCCR MarkingA = Tier 2 (65K) SCCR Marking Digit 29— Low Ambient 0 = NoneA = Low Ambient Cooling to 0°F Model Number Description 18 PKGP-PRC021D-EN General DataTable 5. General data — 12.5 to 25 tons, high efficiency (WHJ