Search Results: 18-HE82D1-2B-EN

Showing 81 - 90 of 7,131 results

Display results per page.
  • Media type icon

    23116740_C_09022025

    4 J11 1 2 3 4 NOTES: ZON E S EN SO R 1. UNLESS OTHERWISE NOTED, ALL SWITCHES ARE SHOWN AT 25° C (77° F), AT ATMOSPHERIC PRESSURE, AT 50% RELATIVE HUMIDITY, WITH ALL UTILITIES TURNED OFF, AND AFTER A NORMAL SHUT DOWN HAS OCCURRED. 2. SOLID LINES INDICATE WIRING PROVIDED BY TRANE CO. DASHED LINES
  • Media type icon

    23116741_C_09022025

    : CUSTOMER PROVIDED: ALTERNATE/OPTIONS: EARTH GROUND: EQUIPMENT CHASSIS: SPLICE (SP): JUNCTION: MULTIPLE WIRE SYMBOL: LINE BREAK:TWISTED CONDUCTORS: SHIELDED CABLE: SYMBOL LEGEND TRANE © DATE: TRANE ® D1(BR) D2(O) D3(Y) 1X(BR) 1A(R)1B(R) 1X(BR) 2A(BK) 2X(O) 3X(Y) 2B(BK)2X(O) 3X(Y) 7A(BR) 7A(BR) 8A(O) 8A(O
  • Media type icon

    12134656_B_02202023

    Document Title:IPAK 2 POWER SCHEMATIC 90-150T AIRFLOW WITHOUT BYPASS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-20
    10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 THIS DRAWING IS PROPRIETARYAND SHALL NOT BE COPIED ORITS CONTENTS DISCLOSED TO OUTSIDE PARTIES WITHOUT THEWRITTEN CONSENT OF TRANE
  • Media type icon

    12134355_B_09012022

    Document Title:IPAK1 POWER SCHEMATIC 90-130T AIRFLOW, WITH BYPASS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-09-01
    1M 2M 3A 3M 3L (Y) 3L 2L (O) 2L 1L (BR) 1L 6XJ112 91A (BR)92A (O)93A (Y) BR BR BR BRBR BRBR BR BR O O O OO OO O O Y Y Y YY YY Y Y BR BR BR BR BR BR BR BR BR BR BR BR O O O O O O O O O O O O Y Y Y Y Y Y Y Y Y Y Y Y 1XP2 16A(BR) 17A(O) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
  • Media type icon

    BAS-PTS011A-EN_11152024

    Document Title:Symbio™ 800 Integration Points List BACnet® for Ascend™ Air-Cooled Chiller Models ACS and ACX with Symbio™ Controls
    Publication Type:Points List
    Publication Date:2024-11-15
    : BAS-SVP083*-EN Object Identifier Diagnostic Name Object StatesBI - 11207 Comm Loss: Run Command Compressor 2B 0 = Normal 1 = In Alarm BI - 11208 Comm Loss: Run Command Compressor 2C 0 = Normal1 = In Alarm BI - 11209 Diagnostic: MP: Invalid Configuration 0 = Normal1 = In Alarm BI - 11210 Diagnostic: MP
  • Media type icon

    SS-SVX11N-EN_06182022

    RIGHT SIDE OF UNIT CLEARANCE 48". 227 1/4” 2 1/4" x 1 1/4" 24 VOLTAGE Dimensions and Weights 28 SS-SVX11N-EN Figure 18. Air-cooled condensing unit connections — 100 and 120 tons 1 3/8"HOT GASBYPASS (OPTIONAL) 1 1/8" O.D.LIQUID LINE CONNECTION COMPRESSOR (6) SUCTION LINE COILCOMPRESSOR (6) LIQUID
  • Media type icon

    2313-0319A_07142010

    Document Title:Connection Electrical Cooling/Mod Gas Heat 208-230V YC 210E, 240E
    Publication Type:Wiring Diagram or Manual
    Publication Date:2010-07-14
    DAÑO AL EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE SONT PAS CONÇUESPOUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. L'UTILISATION DE TOUT AUTRE CONDUCTEUR PEUTENDOMMAGER L'ÉQUIPEMENT. PRECAUCIÓN ATTENTION 15 13 12 12 11 13 13 13 14 7 7 14 21 18 18 19 4 4 23 23 23 24 11 24 WIRING TO BMS 36V(GR) 5 FUSE REPLACEMENT TABLE FU1, FU2 208-230V TYPE FLQ 20 AMP Sheet 1
  • Media type icon

    2313-0333A_07132010

    Document Title:Connection Electrical Cooling/Gas Heat 380V YC 180E, 210E, 240E
    Publication Type:Wiring Diagram or Manual
    Publication Date:2010-07-13
    DAÑO AL EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE SONT PAS CONÇUESPOUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. L'UTILISATION DE TOUT AUTRE CONDUCTEUR PEUTENDOMMAGER L'ÉQUIPEMENT. PRECAUCIÓN ATTENTION 15 13 12 12 11 13 13 13 14 7 7 14 21 18 18 19 4 4 23 23 23 24 11 24 WIRING TO BMS 36V(GR) 5 FUSE REPLACEMENT TABLE FU1, FU2 208-230V TYPE FLQ 20 AMP Sheet 1
  • Media type icon

    2313-0339A_07142010

    Document Title:Connection Electrical Cooling/Gas Heat 400-575V YC 151E, 181E
    Publication Type:Wiring Diagram or Manual
    Publication Date:2010-07-14
    COBRE! LAS TERMINALES DE LA UNIDAD NO ESTÁN DISEÑADASPARA ACEPTAR OTROS TIPOS DE CONDUCTORES. SI NO LO HACE, PUEDE OCASIONAR DAÑO AL EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE SONT PAS CONÇUESPOUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. L'UTILISATION DE TOUT AUTRE CONDUCTEUR PEUTENDOMMAGER L'ÉQUIPEMENT. PRECAUCIÓN ATTENTION 15 13 12 12 11 13 13 13 22 14 7 7 14 22 21 18 18 19 4 4 24 11 24 WIRING TO BMS 36V(GR) 5 Sheet 1
  • Media type icon

    2313-0338A_07142010

    Document Title:Connection Electrical Cooling/Gas Heat 208-230V YC 151E, 181E
    Publication Type:Wiring Diagram or Manual
    Publication Date:2010-07-14
    EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE SONT PAS CONÇUESPOUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. L'UTILISATION DE TOUT AUTRE CONDUCTEUR PEUTENDOMMAGER L'ÉQUIPEMENT. PRECAUCIÓN ATTENTION 15 13 12 12 11 13 13 13 22 14 7 7 14 22 21 18 18 19 4 4 24 11 24 WIRING TO BMS 36V(GR) 5 FUSE REPLACEMENT TABLE FU1, FU2 208-230V TYPE FLQ 20 AMP Sheet 1