Search Results: 18-CH94D1-1C-EN

Showing 381 - 390 of 7,136 results

Display results per page.
  • Media type icon

    UH-SVX01A-EN_09032008

    Document Title:S and P Unit Heaters
    Publication Type:Installation Operation and Maintenance
    Publication Date:2008-09-03
    307 320 Temperature (°C) (131) (138) (142) (148) (153) (160) Steam PSI 25 35 40 50 60 75 Pressure (kPa) (172.4) (241.3) (275.8) (344.7) (413.6) (517.1) Correction Factor 0.83 0.80 0.76 0.73 0.70 0.69 18 UH-SVX01A-EN Installation Piping To provide proper coil operation, follow all piping
  • Media type icon

    PNL-W-1_09011987

    Document Title:CenTraVac Instrument Panels - Models CTV, CV, OCV, PCV - 50L - 300L (Single), 800 - 1200 (Duplex)
    Publication Type:Wiring Diagram or Manual
    Publication Date:1987-09-01
  • Media type icon

    18-GJ53D1-5A-EN_07152020

    Document Title:Installer's Guide Coil TXV Kit for Hyperion and ForeFront TEM Air Handlers
    Publication Type:Installation
    Publication Date:2020-07-27
    comply with NATIONAL, STATE AND LOCAL CODES 18-GJ53D1-5A-EN Fits Models: HyperionTM, ForeFrontTM, and TEM Air Handlers Coil TXV Kit:BAYATXV1836CBAYATXV4248CBAYATXV6060CBAYATXV6161C ⑦ ⑧ ⑨ ② 2 18-GJ53D1-5A-EN COIL THERMAL EXPANSION VALVE INSTALLER'S GUIDE Installation Instructions1. If air handler has
  • Media type icon

    18-CH34D1-8B-EN_06032024

    18-CH34D1-8B-EN 1 DESCRIPTION AND USAGEKit Contents: This Installer's Guide covers installation of the concentric vent kit on all gas fired direct vent condensing furnaces. Only one vent kit per each furnace is allowed.Vent kit is for 2, 2-1/2 or 3 in. diameter pipe systems, (See Figures 3, 4, 5
  • Media type icon

    SO-SVN033A-EN_10132023

    Document Title:CVRF - Symbio™ Chiller Controller Retrofit Replacement Panel Double Door Pneumatic
    Publication Type:Installation
    Publication Date:2023-10-13
    route low-voltage leads with other conductors carrying 30 or more volts. Figure 12. Epoxy application Figure 13. Sensor mounting with Armaflex insulation 18 SO-SVN033A-EN Installation Option I/O InstallationWire additional LLIDs as shown on schematics. Pay careful attention to which LLIDs require low
  • Media type icon

    18-AD53D1-1A-EN_02122024

    Document Title:Installer's Guide - Cased Aluminum Replacement Coils 4TXC-RS
    Publication Type:Installation
    Publication Date:2024-12-02
    , serious injury, or equipment damage. IMPORTANT: Review your installation requirements. Check the table on the outline drawings and note all dimensions for your coil before beginning the installation. Figure 1 18-AD53D1-1A-EN Cased Aluminum Replacement CoilsModels
  • Media type icon

    18-HE72D1-3B-EN_07062023

    Document Title:Installers guide - Duct Shroud Cover Kit (for Horizontal Ducts) BAYCOVR112 for *TC/WC/YC/DC* *018-60A, BAYCOVR118A for *TC/WC/YC/DC* *018-60A
    Publication Type:Installation
    Publication Date:2023-07-14
    : BAYCOVR112 for *TC*, *WC*, *YC*, *DC**018-60BAYCOVR118 for *TC*, *WC*, *YC*, *DC**018-60 WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING 18-HE72D1-3B-EN Duct Shroud Cover Kit (for Horizontal Ducts) Kit Contents:1 - Left Side1 - Right Side1 - Top6 - #10 x 3/4” - Self drilling screws
  • Media type icon

    ODR-PSD007B-EN_09202025

    control with TXV permits lowambient cooling to 30°F.The addition of the BAYLOAM107A low ambient kit permits ambient cooling to 20°F.Thermostats – Cooling only and heat/cooling (manual and automatic change over). Sub-base to matchthermostat and locking thermostat cover. ODR-PSD007B-EN 17 Notes 18 ODR
  • Media type icon

    PKGR-PSD009B-EN_09102025

    control standard with economizer.(f) Downflow only.(g) Low Ambient cooling requires crankcase heater (BAYCCHT-A).(h) BAYCOVR112,118A will not cover 18-in. square-to-round applications. Preliminary PKGR-PSD009B-EN 5 Product SpecificationsTable 2. Models - 5DCZ5024, 5DCZ5030, 5DCZ5036, 5DCZ5042, 5DCZ5048
  • Media type icon

    MS-SVN056C-EN_02202018

    Document Title:U-Match Systems (R410A) 18,000 to 60,000 BTU/h - 60 Hz / Installation Manual
    Publication Type:Installation
    Publication Date:2018-02-20
    Body Testing port Pump connectionTesting port cover Feeding tube (water) Draining port cover Inclination 1/50 Support bracket for pump tube MS-SVN056C-EN 17 Cassette Unit Installation Distribution ductwork installation Model 18 to 24 Series A = 160mm; Series B = 75mm Model 36 to 60 Series A = 160mm