Search Results: TEMP-PRC013A-EN

Showing 321 - 330 of 7,172 results

Display results per page.
  • Media type icon

    WSHP-SVX024B-EN_12012025

    anti-freeze solution having a freezing point20°F lower than the minimum expected enteringtemperature. 50 WSHP-SVX024B-EN Table 34. Operating pressures in cooling/heating - VSH Model No. Cooling Heating EnteringWater Temp (°F) Water Flow(GPM) SuctionPressure,PSIG DischargePressure(PSIG) Water TempRise
  • Media type icon

    SRV-SVX05D-EN_08082023

    . Capabilities are gross values and are not adjusted for motor heat. 2. Max Ambient Temp is 105 °F. 6 SRV-SVX05D-EN General Information Table 3. Electric heat air temperature rise Model Heater kW Total MBh Temperature Rise (°F) 10 ton 30 102.4 23.6 20 ton 45 153.5 17.7 30 ton 45 153.5 11.8 Note: Air
  • Media type icon

    PKGR-PSD007B-EN_09102025

    71 73 Performance Heating(c) Input BTUH-1st Stage 72000 72000 92000 92000 Input BTUH-2nd Stage 90000 90000 115000 115000 AFUE 81 81 81 81 Temp rise-Min/Max (°F) 30 / 60 30 / 60 40 /70 30 / 60 Product Specifications PKGR-PSD007B-EN 7 Table 3. Models – 5YCZ5042A1090A, 5YCZ5048A1090A, 5YCZ5048A1115A
  • Media type icon

    BAS-SVX081E-EN_11152025

    Document Title:E50 Series Compact Power and Energy Meters BACnet® (E50H2A-T2) for use only with E683 Series Rope CT
    Publication Type:Installation
    Publication Date:2025-11-15
    or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. November 2025 BAS-SVX081E-EN Installation, Operation, and
  • Media type icon

    OAU-SVX01L-EN_06262023

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Discharge Air Temp. Reset for Single Zone VAV 85 Supply Fan Tracking for Exhaust Fan (Field En-abled) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Hot Water Reheat . . . . . . . . . . . . . . . . . . . 85 Expanded Fallback
  • Media type icon

    UH-SVN001B-EN_04242020

    Document Title:Horizontal/Vertical Combustion Air Inlet Kit Category III Venting for Separated Combustion Tubular Gas Fired Unit Heaters Five-Inch Kit for 100,000 to 250,000 Btu/h Units Six-Inch Kit for 300,000 to 400,000 Btu/h Units
    Publication Type:Installation
    Publication Date:2020-04-24
    Heaters - Five-Inch Kit for 100,000 to 250,000 Btu/h Units; Six-Inch Kit for 300,000 to 400,000 Btu/h Units • (1) Part No. 11H03R03612-002: Tube of High Temp Silicone Sealant • (3) Part No. 11H03R09571-006: Gasket, O-ring, 6-in. Figure 4. Kit contents (drawing D8980B) 1 4 3 2 1 4 3 2 6 UH-SVN001B-EN
  • Media type icon

    ACDS-PRC003G-EN_06242020

    Document Title:Split System Air-Cooled Condensers — 20 to 120 Tons
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2020-06-24
    10,000 Correction Multiplier 0.977 0.949 0.917 0.881 0.843 14 ACDS-PRC003G-EN Performance DataFigure 3. Condenser heat rejection (R-410A) — 20 to 120 tons 100 300 500 700 900 1100 1300 1500 1700 1900 2100 2300 2500 15 20 25 30 35 40 45 Temperature Difference (°F)(Condensing Temp - Entering Air Temp
  • Media type icon

    SO-SVN035A-EN_10132023

    Document Title:CVRF - Symbio™ Chiller Controller Retrofit Replacement Panel UCP1
    Publication Type:Installation
    Publication Date:2023-10-13
    Cooling 1 1 LonTalk® 1 Generic BAS 2 WiFi Mobile App 1 Air-Fi BACnet via Zigbee 1 LTE 4G Modem 1 Table 4. Field installed LLIDs for various options (continued) DBI DHVBI DBO HPRO QRO DAIO LON IGV PS 475 PSI Temp Sensor PS 0 to 50 or 475 PSIStarter Module Color Display WiFi AirFi LTE 8 SO-SVN035A-EN
  • Media type icon

    WSHP-SVX020C-EN_02282025

    -27 WSHP-SVX020C-EN 37 Table 19. Operating pressures (continued) ModelEntering Water Temp°F Water FlowGPM Operating Data Cooling Heating SuctionPressure,PSIG DischargePressure,PSIG Water TempRise °F Air TempDrop °F DB SuctionPressurePSIG DischargePressurePSIG Water TempDrop °F Air TempRise °F DB GET
  • Media type icon

    MUA-PRC010C-EN_08122020

    Indoor Gas Fired Make-up Air Units August 2020 MMUUAA--PPRRCC001100CC--EENN Product Catalog Indoor Gas Fired Make-up Air UnitsPackaged Unit for Heating, Cooling, Ventilating,and Make-Up Air Applications ©2020 Trane MUA-PRC010C-EN CopyrightThis document and the information in it are the property of