Search Results: TEMP-PRC013A-EN

Showing 311 - 320 of 7,172 results

Display results per page.
  • Media type icon

    RT-PRC098E-EN_02292024

    Document Title:Packaged Rooftop Air Conditioners Precedent™ Cooling and Gas/Electric Standard Efficiency 6 to 25 Tons — 60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2024-02-29
    indoor fan heat formula, refer to appropriate airflow table notes.2. MBh = Total gross capacity3. SHC = Sensible heat capacity RT-PRC098E-EN 25 Table 6. Gross cooling capacities — 7.5 tons CFMEnt DB(°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) 61 67 73 61 67 73
  • Media type icon

    SRV-SVX05D-EN_08082023

    . Capabilities are gross values and are not adjusted for motor heat. 2. Max Ambient Temp is 105 °F. 6 SRV-SVX05D-EN General Information Table 3. Electric heat air temperature rise Model Heater kW Total MBh Temperature Rise (°F) 10 ton 30 102.4 23.6 20 ton 45 153.5 17.7 30 ton 45 153.5 11.8 Note: Air
  • Media type icon

    RT-PRC096F-EN_02292024

    Document Title:Packaged Rooftop Air Conditioners Precedent™ Cooling and Electric Heat Standard Efficiency 6 to 25 Tons — 60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2024-02-29
    tested in accordance with AHRI 370-2015. For additional information reference the outdoor sound power level data in the performance section. General Data 22 RT-PRC096F-EN Gross Cooling CapacitiesTable 5. Gross cooling capacities — 6 tons CFMEnt DB(°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp
  • Media type icon

    PKGR-PSD007B-EN_09102025

    71 73 Performance Heating(c) Input BTUH-1st Stage 72000 72000 92000 92000 Input BTUH-2nd Stage 90000 90000 115000 115000 AFUE 81 81 81 81 Temp rise-Min/Max (°F) 30 / 60 30 / 60 40 /70 30 / 60 Product Specifications PKGR-PSD007B-EN 7 Table 3. Models – 5YCZ5042A1090A, 5YCZ5048A1090A, 5YCZ5048A1115A
  • Media type icon

    SO-SVN036B-EN_12132024

    Document Title:CVRF - Symbio™ 800 Chiller Controller Retrofit Replacement Panel UCP2
    Publication Type:Installation
    Publication Date:2024-12-13
    Mobile App 1 Air-Fi BACnet via Zigbee 1 LTE 4G Modem 1 Table 4. Field installed LLIDs for various options (continued) DBI DHVBI DBO HPRO QRO DAIO LON IGV PS 475 PSI Temp Sensor PS 0 to 50 or 475 PSIStarter Module Color Display WiFi AirFi LTE General Information SO-SVN036B-EN 9 • Loctite 565 Liquid Thread
  • Media type icon

    BAS-SVX081E-EN_11152025

    Document Title:E50 Series Compact Power and Energy Meters BACnet® (E50H2A-T2) for use only with E683 Series Rope CT
    Publication Type:Installation
    Publication Date:2025-11-15
    or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. November 2025 BAS-SVX081E-EN Installation, Operation, and
  • Media type icon

    BAS-PTS003C-EN_12172025

    Document Title:Symbio™ 800 Integration Points List BACnet®/Modbus™ for IntelliPak™
    Publication Type:Points List
    Publication Date:2025-12-17
    Units Write °F 40 to 110 0 Holding 40015 AV-10149Daytime Warmup Setpoint BAS Defines the space temp below which daytime warmup will be enabled Heat Present and Discharge Temperature Control Write °F 50 to 87 0 Holding 40017 BAS-PTS003C-EN Analog Values 34 Symbio™ 800 Integration Points List BACnet®
  • Media type icon

    BAS-SVX072C-EN_04222021

    Document Title:E50 Series Compact Power and Energy Meter Modbus E50C2A-T2 for use only with E683 Series Rope CTs PN: X13690277001
    Publication Type:Installation Operation and Maintenance
    Publication Date:2021-04-22
    BAS-SVX072C-EN SSAAFFEETTYY WWAARRNNIINNGGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioningequipment can be hazardous and requires specific knowledge and training. Improperly installed
  • Media type icon

    ENV-SLB021-EN_12182025

    ENV-SLB021-EN CoolSense® Integrated Outdoor Air System Flexibility in design and remodel The DOAS is typically sized for only the minimum ventilation airflow required, in turn requiring less ceiling plenum height and allowing for more usable space inside the building. Reconfiguring a zone often
  • Media type icon

    CXAU-MODBUS-EN_07122023

    Document Title:CXAU Centralized Controller MODBUS Communication
    Publication Type:Installation Operation and Maintenance
    Publication Date:2023-07-12
    +6 binary Outdoor Air Temp Out Of Range (0,1) - R 0:no alarm;1: alarm 100*n+7 binary Entering Water Temp Sensor (0,1) - R 0:no alarm;1: alarm 100*n+8 binary Leaving Water Temp Sensor (0,1) - R 0:no alarm;1: alarm 100*n+9 binary Outdoor Air Temp Sensor (0,1) - R 0:no alarm;1: alarm 100*n+10 binary