Search Results: TEMP-PRC013A-EN

Showing 1,581 - 1,590 of 7,121 results

Display results per page.
  • Media type icon

    1213-4445F_09052023

    Document Title:SCHEMATIC; SHEET 5, CONTROLS, INDOOR OPTIONS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-09-05
    LEGENDREF DES DESCRIPTION LINE NOCOF SWITCH - CONDENSATE OVERFLOW 297ETS1 SENSOR - EVAPORATOR TEMP 253IOM MODULE - INDOOR OPTIONS 253SASD SENSOR - SUPPLY AIR SMOKE DETECTOR 245SFT OPTIONAL MOD GAS 298SPT TRANSDUCER - STATIC PRESSURE 267 P1 PPM154 PPF162 1 2 PPM163 1 2 (BK) (BK) (R) (R) PPF163 1 2
  • Media type icon

    1213-4803A_02142024

    Document Title:SCHEMATIC; SHEET 2, POWER, SINGLE INDOOR FAN, 2-STAGE GAS HEAT, 230V, HIGH SCCR, MULTI- TAP MOTOR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-02-14
    MODBUS-1123 MODBUS-LDS1234 53A 53A(O) 54A 54A(Y) BR BR O O PPM249123 BLBL BLY Y YOO O O PPF249 PPM511234 PPF151123 2AP(O)3AM(Y) 144A(G/Y) IPSEE POWER EXHAUST SCHEMATIC FOR BALANCE OF CIRCUIT NOTES: FD IGN 24 VAC OUTADDRESS 1 L1 (IN) GROUND COMMONGAS VALVE STAGE 1 FLAME ROD TEMP LIMIT IN ROLLOUT SWITCH
  • Media type icon

    ENGY-SLB072-EN_10212025

    Document Title:Empowering Education & Energy Savings through Solar Energy at Hardin County Schools
    Publication Type:Sales Brochure
    Publication Date:2025-10-21
    bifacial technology, achieving 21.4% maximum efficiency• Anti-LeTID technology minimizes production loss from high temperatures and sunlight https://www.trane.com/commercial/north-america/us/en/about-us/newsroom/case-studies/k-12/hardin-county-schools.html https://www.trane.com/commercial/north-america
  • Media type icon

    1213-4946B_09122024

    Document Title:SCHEMATIC; SHEET 2, POWER, SINGLE INDOOR FAN, EFLEX, 2-STAGE GAS HEAT, 230V, STD SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-12
    POWER EXHAUST SCHEMATICFOR BALANCE OF CIRCUIT IGN 24 VAC OUTADDRESS 1 L1 (IN) GROUND COMMONGAS VALVE STAGE 1 FLAME ROD TEMP LIMIT IN ROLLOUT SWITCH IN PRESSURE SWITCH IN L1 (OUT)LOW SPEED (OUT)HIGH SPEED (OUT) MODBUS +MODBUS -COMMON 24 VAC INCOMMON 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC
  • Media type icon

    RT-SVX096D-EN_10312025

    an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. October 2025 RT-SVX096D-EN Installation, Operation, and MaintenanceFoundation™ Packaged
  • Media type icon

    18-HE142D1-1A-EN_11202024

    Document Title:Energy Recovery Ventilator (ERV)
    Publication Type:Installation
    Publication Date:2024-11-21
    immediately. Open carton, remove packing material, loose parts and ship-with literature. Check to be sure all major components are in the unit. Any missing parts should be reported to your supplier at once, and replaced with authorized parts only. 18-HE142D1-1A-EN Energy Recovery Ventilator (ERV
  • Media type icon

    PART-SVN147B-EN_05152020

    Document Title:Location of Parts - Motor Change Out Kit, KIT16326, Model Numbers: CVHE / Installation Instructions
    Publication Type:Installation
    Publication Date:2012-06-15
    , adjusted or altered equipment by an unqualified person could result indeath or serious injury. When working on the equipment, observe all precautions inthe literature and on the tags, stickers, and labels that are attached to theequipment. © 2020 Trane Model Number:CVHE May 2020 PART-SVN147B-EN
  • Media type icon

    18-CH12D28-7B-EN_03022023

    - KIT02851 (White-Rodgers Kit #92-0659) A138928P01 1 Propane Label B342003P021 Conversion Label B342003P021 Conversion Responsibility Label B342003P021 Installer's Guide 18-CH12D16-10A-EN 18-CH12D28-7B-EN CAUTION CAUTION Installer's GuideAt the completion of the conversion, replace the front cover of the
  • Media type icon

    BAS-SVN089B-EN_006102020

    Document Title:Replacing the Transformer Service Part in Field-installed DIN EnclosuresOrdering numbers: S3090064262 (120 Vac transformer) S3090064362 (230 Vac transformer)
    Publication Type:Installation
    Publication Date:2020-06-10
    , adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. © 2020 Trane June 2020 BAS-SVN089B-EN Installation
  • Media type icon

    18-HF10D3-1B-EN_07082020

    Document Title:Installation - Anti Short Cycle Time Delay Relay. Model TAYASCT501A
    Publication Type:Installation
    Publication Date:2020-07-21
    . ASCT-IN-5A 18-HF10D3-1B-EN This accessory may be installed on any compressor bearing outdoor section using 24 VAC contactor coil.This accessory MUST be installed in a weather protect-ed area within the unit cabinet such as the control box, the fan orifice plate, etc.1. Mount time delay relay using the