Search Results: TEMP-SLB008-EN

Showing 111 - 120 of 7,117 results

Display results per page.
  • Media type icon

    ODR-SVX024A-EN_12132025

    110.00 43.33 4548 0.31 ODR-SVX024A-EN 27 Table 8. Defrost control thermistor (continued) Temp °F Temp °CThermistorResistance(ohms) Volts DC 115.00 46.11 4079 0.28 120.00 48.89 3665 0.26 125.00 51.67 3298 0.23 130.00 54.44 2972 0.21 135.00 57.22 2683 0.19Example: Sensor temp. = 19°F Measured Resistance
  • Media type icon

    COR-SVN006A-EN_10152025

    Document Title:Installer's Guide - Replacement Coils
    Publication Type:Installation
    Publication Date:2025-10-15
    Temp(Brown) Evap Temp(Orange) Installation COR-SVN006A-EN 17 Figure 23. Temperature sensor for COL32943 Gas Temp(Brown) Sat Temp(Yellow, if equipped) Evap Temp(Orange) Coil Installation for DownflowApplications1. Slide the replacement coil into the unit. See Figure 24, p. 17.Note: Some modifications
  • Media type icon

    18-AC131D1-1A-EN_04232024

    Document Title:Trane Installation and Operation Manual - Condensing Units - 5TTA3036 - 060
    Publication Type:Installation
    Publication Date:2024-04-23
    temperature is above 55º F. LIFT STEP 1 - Use the refrigerant line total length and lift measurements from Section 5.3. Total Line Length = __________ Ft. Vertical Change (Lift) = __________ Ft. 14.2 Subcooling Charging in Cooling (Above 55º F Outdoor Temp.) 18-AC131D1-1A-EN 13 Design Subcooling Value
  • Media type icon

    MC-PRC005-EN_12102012

    Document Title:Product Catalog - Trane Chilled Water Fan and Coil Units
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2012-12-10
    setting. 20 MC-PRC005-EN Electrical and Controls Wireless Remote Controller � Mode selection: Auto, Cool, Dry, Heat, Fan only � Temp. setting range: 17 to 30 � Daily Timer setting � Louver swing � Fan speed control: H/M/L/Auto � Economic operation button MC-PRC005-EN 21 Capacity Tables Capacity
  • Media type icon

    COIL-PRC002M-EN_12012025

    220 5/8in. —— Coil Applications 10 COIL-PRC002M-EN Table3. Heatin gandcoolingwater coils (con tinued) Coil CoilType CoilD rawing Features Row sFinn edWidth FinSp acing perF oot Finn edLeng thTube Material Max.Std. Operatin gCon ditio ns(a) Tube dia (inch) App lication Press PSI Temp °FHeat Coo l P4
  • Media type icon

    TEMP-SVN009A-EN_05122024

    Document Title:Trane Rental Services
    Publication Type:Installation
    Publication Date:2024-05-12
    Switch Fan Selector Switch Start-Up Instructions Trane Rental ServicesRSHX00**F4 Voyager™ May 2024 TEMP-SVN009A-EN TEMP-SVN009A-EN 12 May 2024 (NEW) 13.If needed, disable outdoor damper by turning the Economizer Enable switch to Disable. If leaving Economizer enabled, adjust outdoor damper minimum
  • Media type icon

    TEMP-SLB003-EN_06042025

    Document Title:Trane Rental Services Cold Storage - Precision Temperature Controlled Cold Storage Solutions
    Publication Type:Sales Brochure
    Publication Date:2025-06-04
    TEMP-SLB003-EN_06042025.indd Trane Rental Services Cold Storage units are designed to create and maintain ultra-low temperatures as low as -94°F (-70°C), showcasing the advanced technology that ensures the protection of the most sensitive and valuable cargoes. These units are based on Thermo King’s
  • Media type icon

    TEMP-SLB004-EN_06042025

    Document Title:Trane Rental Services Process Cooling Air-Cooled Industrial Chillers with Scroll Compressors - Nominal Cooling Capacity 3-40 Tons
    Publication Type:Sales Brochure
    Publication Date:2025-06-04
    TEMP-SLB004-EN_06042025.indd Many manufacturing and industrial sites require process cooling to remove heat which increases efficiency of production process and operational effectiveness of equipment. Trane has a line of temporary industrial chillers to support our customers ever changing needs
  • Media type icon

    BAS-PTS038B-EN_09262025

    Document Title:Symbio™ 500 Integration Point List BACnet® Self-Contaned (SWUD*)
    Publication Type:Points List
    Publication Date:2025-09-26
    Reference Document: BAS-SVP087*-EN Object IdentifierObject Name Description Configuration Dependency Read/ WriteUnits Low Limit High Limit AI-1 Space Temperature LocalIndicates the space temperature value from a sensor wired to the controller Unit Controls = Space Control or VAV with Space temp
  • Media type icon

    BAS-PTS031A-EN_12062024

    Document Title:Symbio™ 800 Integration Points List BACnet® for RTAC (CH530)
    Publication Type:Points List
    Publication Date:2024-12-06
    Symbio™ 800 Integration Points ListBACnet®RTAC (CH530) Date: 12/6/2024Reference Document: BAS-SVP083*-EN Object Naming ConventionsThe communicated points for the Symbio™ controllers are generally named according to their function. While many of the points are read-only, others include both read and