Search Results: yzc

Showing 1 - 8 of 8 results

Display results per page.
  • Media type icon

    RT-SVX46G-EN_01162021

    Conditioner 57 YZC (Parts Only) . . . . . . . . . . . . . . . . . . . . 57 Models Less Than 20 Tons for Commercial Use* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 RT-SVX46G-EN 5 Model Number DescriptionDigit 1 - Unit TypeT DX CoolingY DX Cooling, Gas Heat Digit 2 - EfficiencyZ Ultra
  • Media type icon

    4366-8511A_08082014

    Document Title:Precedent Wiring Diagram; Ultra High Efficiency eFlex Precedent Power Diagram - YZC048E4, YZC060E4, Variable Speed Compressor
    Publication Type:Wiring Diagram or Manual
    Publication Date:2014-08-08
    DO NOT SCALE PRINT DRAWN BY: THIRD ANGLEPROJECTION CDATE: TRANE REV THIS DRAWING IS PROPRIETARY AND SHALL NOT BECOPIED OR ITS CONTENTS DISCLOSED TO OUTSIDEPARTIES WITHOUT THE WRITTEN CONSENT OF TRANE TRANE D. SHANNON 16-AUG-13 4366-8511 A DIAGRAM CONNECTION PRINT YZC(048,060)E4 ULTRA HIGH
  • Media type icon

    ACC-SVN11N-EN_06032020

    Document Title:Ventilation Override Kit Used with 3 to 10 Ton Packaged Units with ReliaTel™ Controls
    Publication Type:Installation
    Publication Date:2020-06-03
    equipped with a plenum fan, Y/TSC120F, Y/THC074, Y/THC092-120E/F, Y/TZC072-120, YZC 072-120, D/WHC074-120H & WSC120H models, check the indoor/outdoor divider panel for a knockout just below the control box. If knockout exists, remove it in preparation for installing the harness. If it does not exist
  • Media type icon

    ACC-SVN139M-EN_06262023

    Control BoxAccess Panel LTB Wireharness ACC-SVN139M-EN 5 Installation T/YZC(072, 090, 102), D/WHC090**, and D/WSC120** 18. Refer to Figure 1, p. 4 and locate the RTOM module behind the fan access panel. Check the panel for two mounting holes below the RTOM. If holes exist, mount the RTVM with two ea
  • Media type icon

    ACC-SVN57N-EN_04232020

    Document Title:Power Exhaust Kit - Standard and Low Leak Economizers 6 to 10 Tons
    Publication Type:Installation
    Publication Date:2020-04-23
    W43 to compressor contactor L3. c. Replace compressor access panel. Note: FOR T/YZC 072-120 units: Power can be routed to power-in side of indoor fan 30 amp fuse block, or stripped and fed into T1&T2 of the high voltage terminal block, TB1. Electromechanical Unit Power Exhaust Operation and
  • Media type icon

    RT-PRC053L-EN_12202022

    Document Title:Packaged Rooftop Air Conditioners Precedent™ with eFlex™ Technology — Cooling and Gas/Electric 3 to 10 Tons — 60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2022-12-20
    %, dehumidification will be terminated and the unit will transition back to normal cooling or heating control. RT-PRC053L-EN 21 Selection Procedure Cooling CapacityNote: Cooling Capacity Procedure is the same for electric heat (TZC) and gas heat (YZC). 1. Calculate the building's total and sensible cooling loads at
  • Media type icon

    RT-SVX45F-EN_04022020

    Document Title:Packaged Rooftop Air Conditioners Precedent™ with eFlex™ Technology, Electric/Electric 3 to 10 Tons - 60 Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-04-02
    option. 10. Discharge Air Temperature Sensor is also standard equipment on units with Single Zone. 11. Standard on T/YZC 4 ton models. 12. Epoxy coil and epoxy with hail guard option not available for units with microchannel condenser coil. 13. Requires selection of 2” pleated filters (option B or C) for
  • Media type icon

    ACC-SVN175F-EN_04242020

    packaged rooftop units Note: 6-10 ton T/YZC and TSC/WSC Precedent™ Comm Board mounted in same location, except at 90° on HV/LV divider panel 6 to 10 Tons Packaged Rooftop Units, 4 to 5 Tons Precedent™ high efficiency, 17 Plus and 5 Ton Precedent™ Heat Pump units: Mount the LonTalk® Communication