Search Results: 18-HE82D1-2B-EN

Showing 981 - 990 of 7,130 results

Display results per page.
  • Media type icon

    BAS-PRD016D-EN_10272023

    October 2023 BAS-PRD016D-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed
  • Media type icon

    PKGR-SVX009B-EN_10062025

    Document Title:Installation and Operations Manual - Single Packaged Cooling/Electric Heat, Entry, Convertible, 2-5 Ton, R-454B, A5PA
    Publication Type:Installation
    Publication Date:2025-10-06
    appropriatecurb. Note: Use the extreme mounting kit, BAYEXMK003, tosecure the unit to the slab. 18 PKGR-SVX009B-EN Figure 3. Typical ground level application SIDING RETURN AIR DUCT SUPPLYAIR DUCT EXTERIORWALL INSULATE WEATHERPROOFOR RAIN SHIELD FLEXIBLE DUCT CONNECTORS OUTDOORAIR DISCHARGE SUPPORT
  • Media type icon

    RT-SVX095C-EN_08182025

    UNIT LEFT VIEW OF UNIT FAN MANUAL DAMPER HOOD 123 1/8” 18 1/4” 26 7/8” 24 7/8” 12 13/16” 86 15/16” Dimensional Data RT-SVX095C-EN 17 WeightsTable 1. Maximum unit and corner weights (lb) and center of gravity dimensions (in.) Tons Unit ModelNo. Weights (lb)(a) , (b) Corner Weights(c) Center of Gravity
  • Media type icon

    RRCA-SVX01B-EN_10012001

    Document Title:Installation Operation Maintenance - MityVac High Pressure, Light Commercial Microprocessor and Electromechanical Refrigerant Recovery Systems
    Publication Type:Installation Operation and Maintenance
    Publication Date:2001-10-01
    Replacement P RRCA-SVX01B-EN 17 MicroprocessorReplacement Parts Figure 3 � MityVac Replacem 18 RRCA-SVX01B-EN ElectromechanicalGeneral Information Product Description RefTec�s MityVac recovery system provides efficient and safe recovmost high pressure refrigerants and blends. The unit consists of a 1.5-up
  • Media type icon

    PART-SVN276A-EN_09152025

    Document Title:Installation Guide -- Horizontal Flat "Cased" Copper/Aluminum Coils
    Publication Type:Installation
    Publication Date:2025-09-15
    clean. 18 PART-SVN276A-EN Figure 7. Troubleshooting indoor TXV / cooling mode Is sub cooling at the outdoor unit between 8 to 12F? NO YES Is superheat < 5F? YES Correct air flow problem Is air flow at least 350 CFM per ton? YES NO Remove sensing bulb from the suction line. Measure superheat at indoor
  • Media type icon

    23116005_B_05122023

    Document Title:Field Layout
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-05-12
    C AVERTISSEMENT ADVERTENCIA WARNINGPRECAUCIÓN ATTENTION CAUTION RELEASED 12/May/2023 16:18:23 GMT AutoCAD SHX Text REV AutoCAD SHX Text SHEET AutoCAD SHX Text DATE: AutoCAD SHX Text DRAWN BY: AutoCAD SHX Text SIMILIAR TO: AutoCAD SHX Text REVISION DATE: AutoCAD SHX Text REPLACES: AutoCAD SHX Text
  • Media type icon

    WSHP-PRC039B-EN_02142025

    . This Application Considerations 18 WSHP-PRC039B-EN product contains a leak detection system if a circuit charge is greater than 3.91 lbs. As a result, nofurther leak detection system evaluation is required. • The second threshold defines when additional ventilation airflow is required. If the room
  • Media type icon

    TCA-SVX001B-EN_01282026

    external cooling tower(water-cooled only). Condenser PumpEnable Binary output to enable external condenserpumping package (water-cooled only) 18 TCA-SVX001B-EN Pre-Start-UpPreparation for Initial Start-UpAfter the system is completely installed with all wiresconnected and all piping securely coupled
  • Media type icon

    ACC-SVN264G-EN_02132026

    Document Title:Low Leak Economizer – Precedent™ Packaged Rooftop Units 6 to 25 Tons with Symbio™
    Publication Type:Installation
    Publication Date:2026-02-13
    to the return air front block-off that was previously installed in Step 4.. Installation – FIAECON103* 18 ACC-SVN264G-EN Figure 16. Damper assembly attachment to block-off Secure Outdoor Air Damper Assembly to Front Block-off Panel with screws 9. Route the controls harness from the actuator to the
  • Media type icon

    SSP-SVX001E-EN_01122025

    shows 10 feet of suction lift with 48 feet total pipelength. This example complies with . Figure 11. Piping example 18 SSP-SVX001E-EN Figure 12. Allowable elevation difference: TTA or TWA below indoor unit Acceptable liquid-riser height based on total liquid-line length(below indoor unit) For TTA units