    BAS-SVX093B-EN_04082023

    Supersedes BAS-SVX093A-EN (October 2022) ©2023 Trane BACnet® Protocol BACnet Testing Laboratory (BTL) Certification Specifications and Dimensions Device Connections Additional Components Water, Discharge, and Outdoor Air Temperature Sensors Binary Input Switching Devices Zone Temperature Sensors Valve and
  • Media type icon

    VAV-SVX08AC-EN_11152025

    1786 843 80% 8.0 8.4 1865 880 85% 8.5 8.8 1943 917 90% 9.0 9.2 2022 954 95% 9.5 9.6 2100 991 100% 10.0 10.0 (a) % setting from Trane unit controller via pulse width modulating signal or ECMcontrol board with manual fan speed adjust setting. (b) ECM control board with 0-10 Vdc fan modulation input
  • Media type icon

    22-8301-35_4Q_06242022

    FURNACES 2022 PRODUCT HANDBOOK 22-8301-35 ONLINE O NLY C OPY Go to TraneProducts.com/db and register for FREE Follow the simple on-screen instructions Copy your unique IFRAME code to your website STEP 1 STEP 2 STEP 3 Instantly, the full line of Trane Products will be displayed on your website and will be
  • Media type icon

    BAS-SVP066B-EN_04132024

    Document Title:BACnet® and Modbus™ Integration to Voyager™ 3 Packaged Rooftop Air-Conditioners with Symbio™ 700 Controls
    Publication Type:Integration Guide
    Publication Date:2024-04-13
    of continuous product and product data improvements and reserves the right to change design and specifications without notice. Weare committed to using environmentally conscious print practices. BAS-SVP066B-EN 13 Apr 2024 Supersedes BAS-SVP066A-EN (November 2022) ©2024 Trane Overview Purpose Symbio™
  • Media type icon

    BAS-SVX091B-EN_04082023

    Document Title:Symbio™ 500 Programmable BACnet® Controller for Variable-Air-Volume (VAV) Units
    Publication Type:Installation Operation and Maintenance
    Publication Date:2023-04-08
    print practices. BAS-SVX091B-EN 08 Apr 2023 Supersedes BAS-SVX091A-EN (October 2022) ©2023 Trane BACnet® Protocol BACnet Testing Laboratory (BTL) Certification Specifications and Dimensions Shipping and Storage Symbio 400 Controller Features Controller Comparisons Device Connections Expansion Modules
  • Media type icon

    CLCH-PRC032D-EN_12012025

    Refrigeration Systems and Machinery RoomsApplication Considerations for Compliance with ASHRAE® Standard 15-2022 Application Engineering Manual (APP-APM001*-EN) for more information. Leak Detection System(R-454B charge greater than 3.91 lb per circuitor R-32 charge greater than 4.04 lb per circuit)The
  • Media type icon

    WSHP-PRC033B-EN_06302025

    than UL 60335-2-40 requirements. See Refrigeration Systems and Machinery RoomsApplication Considerations for Compliance with ASHRAE® Standard 15-2022 Application Engineering Manual (APP-APM001*-EN) for more information. Application Considerations 28 WSHP-PRC033B-EN Minimum Room Area Limits
  • Media type icon

    FNR-SVX003A-EN_10312025

    1335 / 203 1334 / 271 1330 / 341 1323 / 414 5.0 (a) 450 CFM / Watts 2236 / 561 2250 / 678 2260 / 796 2266 / 913 2270 / 1031420 CFM / Watts 2101 / 466 2114 / 575 2123 / 684 2128 / 793 2130 / 903400 CFM / Watts 2009 / 409 2022 / 512 2029 / 616 2033 / 720 2035 / 825370 CFM / Watts 1869 / 333 1880
  • Media type icon

    RT-PRC122C-EN_11152025

    specific requirement of ANSI/ASHRAE Standard 15, Safety Standard for RefrigerationSystems, could be more stringent than UL 60335-2-40 requirements. See Refrigeration Systems and Machinery RoomsApplication Considerations for Compliance with ASHRAE® Standard 15-2022 Application Engineering Manual (APP
  • Media type icon

    PKGP-PRC023D-EN_09122025

    Document Title:Precedent™ Packaged Rooftop Units
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-09-12
    Refrigeration Systems and Machinery RoomsApplication Considerations for Compliance with ASHRAE® Standard 15-2022 Application Engineering Manual (APP-APM001*-EN) for more information. Minimum Room Area Limits(Refrigerant charge greater than 3.91 lb per circuit)Equipment with R-454B charge amounts