Search Results: 18-CH94D1-1C-EN

Showing 941 - 950 of 7,136 results

Display results per page.
  • Media type icon

    RRU-SVX01F-EN_11012021

    Clearances Figure 8. Unit dimensional data 12.5-, 15-, and 20-ton high efficiency 18 RRU-SVX01E-EN Unit Weight/Rigging Rigging Refer to Figure 9 and Table 1 for typical unit operating weights rigging before proceeding. 3. Remove the shipping crate from around the unit. Do not remove the crating from the top
  • Media type icon

    FNR-PSD015A-EN_07012025

    for A801X with single stage AC or heat pump with two stage airflow FNR-PSD015A-EN 17 Dimensional DataFigure 5. 14.5-inch, 17.5-inch, 21-inch and 24.5-inch width cabinets 18 FNR-PSD015A-EN Notes FNR-PSD015A-EN 19 Notes About Trane and American Standard Heating and Air ConditioningTrane and American
  • Media type icon

    RT-PRC115D-EN_05152026

    Document Title:Precedent™ Packaged Rooftop Units
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2026-05-15
    on downflow or horizontal Multi-Speed Indoor Fan SystemNote: Not available with 3 to 5 ton standard efficiency units. Features and Benefits 18 RT-PRC115D-EN This system incorporates multi-speed fan control to change the speed of the fan to 66 percent of full airflow depending oncompressor stages
  • Media type icon

    RT-SLB061-EN_11182024

    RT-SLB061-EN 11/18/2024© 2024 Trane. All Rights Reserved. Trane – by Trane Technologies (NYSE: TT), a global climate innovator – creates comfortable, energy efficient indoor environments through a broad portfolio of heating, ventilating and air conditioning systems and controls, services, parts and
  • Media type icon

    DOAS-PRC001N-EN_10312025

    Document Title:CoolSense™ Chilled Water Sensible Cooling Terminal Units
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-10-31
    . Size the valve for a Cv = 1/2 the GPM it must pass inmodulating applicationsThe equation that governs valve sizing is: Cv =GPM ∆P Where• Cv = Flow coefficient Application Considerations 18 DOAS-PRC001N-EN • GPM = The maximum water flow rate through the valve in gallons per minute• ΔP = The maximum
  • Media type icon

    ODR-PSD008B-EN_09202025

    ODR-PSD008B-EN_09202025 September 2025 ODR-PSD008B-EN Split System Cooling5TTR4018A1000A5TTR4024A1000A5TTR4030A1000A/B5TTR4036A1000A/B5TTR4042A1000A/B5TTR4048A1000A/B5TTR4060A1000A/B Note: Graphics in this document are for representation only.Actual model may differ in appearance. Product and
  • Media type icon

    PKGP-SVX010C-EN_08192023

    Document Title:Packaged Rooftop Air Conditioners Precedent™ Heat Pump Standard Efficiency 12.5 to 25 Tons — 60 Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2023-08-19
    25 tons standard efficiency – horizontal airflow supply/return 46 1/2''[1181] 6''[153] 20''[508] 25 1/2''[648] 26 3/4''[679] 29''[737] 5 1/4''[133] 22 3/8''[570] 18 7/16''[468] 4 9/16''[114] 7 15/16''[202] 5 1/2''[141] SUPPLY RETURN Dimensional Data PKGP-SVX010C-EN 15 Figure 6. 12.5 to 25 tons
  • Media type icon

    PART-SVN251A-EN_01012021

    130–400 Ton RTAA Chiller Controls Upgrade ProcedureMOD01421 and BRD03015 No LongerAvailable Installation Instructions Models: RTAA, KIT16221 January 2021 PART-SVN251A-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing
  • Media type icon

    COR-SVN006B-EN_05012026

    Document Title:Installer's Guide - Replacement Coils
    Publication Type:Installation
    Publication Date:2026-05-01
    . Snap tab feature Snap TabFeature 2. Repeat for right rear tab to release top baffle assemblyfrom coil. 3. Rotate the top baffle 180 degree and snap all fourcorners to lock in place. See the figure below. Figure 18. Rotate top baffle Installation 16 COR-SVN006B-EN Figure 19. Install top baffle 4
  • Media type icon

    AFDG-SVU01L-EN_05122020

    524 241 663 289 666 343 666 154 100K 524 191 524 241 663 289 666 343 666 18 AFDG-SVU01L-EN Input Power and Control Wiring Installing Input Power Wiring Standard Cabinet Use the following steps to connect AC input power to the cabinet: WARNING Hazardous Voltage w/Capacitors! Failure to disconnect