    18-CH12D27-2A-EN_07202020

    Document Title:Installer’s Guide - HIGH ALTITUDE CONVERSION KITS for *UX2, *DX2, *UX-R, *DX-R, *UY-R, and *DY-R Furnace Models
    Publication Type:Installation
    Publication Date:2020-07-29
    Models:BAYHALT245BAYHALT246BAYHALT247 INSTALLER'SGUIDE IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES 18-CH12D27-2A-EN
  • Media type icon

    GLND-SVX01C-EN_07112020

    Document Title:Gas Unit Heater Indoor Gas-Fired Duct Furnace
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-07-11
    property-only-damage. Figure 10. Pipe installation, standard controls 18 GLND-SVX01C-EN Installation: Piping Table 5. Gas piping requirements Gas Type Natural Gas Propane (LP) Gas Single Stage Gas Piping Requirements(a) (a) For single stage applications only, at normal altitudes. Manifold Pressure 3.5
  • Media type icon

    RTAF-SVX001P-EN_04302026

    Document Title:Sintesis™ Air-Cooled Chillers Model RTAF
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-04-30
    Information RTAF-SVX001P-EN 13 Figure 2. Evaporator piping and compressor locations Compressor 1A Compressor 1B Compressor 2A Compressor 2B Contr ol Pa nel Circu it 1 Contro l Panel Circu it 2 3-Compressor Units(280 to 390 tons) 4-Compressor Units(410 to 520 tons) Compressor 1A Compressor 1B Compressor 2A
  • Media type icon

    SRV-SLB238-EN_07132020

    Document Title:Thermal Energy Storage / Infographic
    Publication Type:Sales Brochure
    Publication Date:2020-07-13
    SRV-SLB238-EN THERMAL ENERGY ANDOUT OF THATALMOST HALF40% of the world’senergy 1 due to HVAC 1 by 20402 forecasted to grow by power transformers are over 25 years old.4 72have already, or are now set to 3 Sources: 1 EIA / 2 3 4 Energy Department, 2014 13%70% “The value of Thermal Energy Storage
  • Media type icon

    BAS-SVX071C-EN_04222021

    Document Title:E50 Series Compact Power and Energy Meter BACnet MS/TP E50H2A-T2 for use only with E683 Series Rope CTs PN: X13690276001
    Publication Type:Installation Operation and Maintenance
    Publication Date:2021-04-22
    accumulator as described above, and one phase lossalarm output terminal. Figure 3. Pulse Contact Input SComm Output + ~10 kΩ CommGround 4-10 VDCnominal Equivalent Circuit Pulse Input Contacts 18 BAS-SVX071C-EN User Interface The user can set the display mode to either IEC or IEEE notation in the SETUP
  • Media type icon

    18-CH90D1-1A-EN_07062020

    Document Title:Service Installer's Guide KIT18092 C1 Replacement Inducer Furnace Model Families *UD040C924**, *UC040C930** *(*May be A or T, ** May be "A" - "Z")
    Publication Type:Installation
    Publication Date:2020-07-30
    . 18-CH90D1-1A-EN Item No. Drawing No. Description Qty 1 D340032P01 Box, Flue Collector 12 A340089P01 Tube, Pressure Switch 13 D342077P01 Blower, Induced 1 Stage 14 C340033P01 Gasket, Collector Box 15 C138216P03 Gasket, Venter Assembly 16 N154CP1608B Scr 10-16 AB HWH 1/2 S 13 C1 Replacement Inducer
  • Media type icon

    PART-SVN82C-EN_09012004

    Document Title:Replacement of RLY00765 with KIT09437 using Tracer CH531 Components
    Publication Type:Installation
    Publication Date:2004-09-01
    Superseded By:PART-SVN82C-EN
    , X39470320 PART-SVN82C-EN 18 C A D IVIS ION OF AM ER ICA N S TA ND AR D IN C. ALL R IGH TS RE SE RV ED Appendix B Figure B1. RLY00765 to CH531 wiring details, 5068-8478, Rev. B PART-SVN82C-EN 19 C A D IVIS ION OF AM ER ICA N S TA ND AR D IN C. ALL R IGH TS RE SE RV ED Appendix B Figure B2. RLY00765 to CH531
  • Media type icon

    RTHE-PRC002-EN_01012015

    Document Title:RTHE Series R Helical Rotary Liquid Chiller 75-255 Tons 60Hz / Product Catalog
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2015-01-01
    - Condenser Pressure (%HPC) OutputD - Differential Pressure Output Digit 17 Motor Current Analog Output (%RLA)X - NoneA - Motor Current Analog Output Digit 18 Distribution AreaA - ChinaB - Out of ChinaC - LAR Digit 19 Technical Data RTHE-PRC002-EN 7 Table 1. Rating table final Model 75 90 110 130 175
  • Media type icon

    SO-SVN037B-EN_12112023

    mounting location chosen due to retrofitted insulation layers Figure 18. Arm/display assembly mounted at alternate location 14 SO-SVN037B-EN Installation . 3. Secure the arm to the control panel bracket using the 5/16 - 18 x 1-inch hex bolts, 5/16-inch lock washers, and 5/16 - 18 hex nuts provided.Note
  • Media type icon

    MUA-PRC010C-EN_08122020

    -PRC010C-EN • Evaporative Cooling with standard 8 inch or optional 12 inch media (203 or 305 mm). • Standard 18-gauge Cabinets, Painted Gray. • Standard 20-gauge Aluminized Steel Heat Exchanger. • Standard 1 inch Washable Filters. • Standard Single Stage Combination Gas Valve. • Standard High