Search Results: 18-HD83D1-5B-EN

Showing 621 - 630 of 7,116 results

Display results per page.
  • Media type icon

    18-GE10D1-5_03012008

    Document Title:Installer's Guide- Convertible Variable Speed – Air Handlers 2 1/2 - 5 Ton with Integrated Whole House Air Cleaner 2/4TEE
    Publication Type:Installation
    Publication Date:2008-03-01
    ............................................... 18 Outline Drawings ................................................. 20 Checkout Procedures .......................................... 23 INSTALLATION LIMITATIONS & RECOMMENDATIONSThe general location of the air handler is normally se-lected by the architect, contractor and/or home ownerfor the
  • Media type icon

    18-HD30D2-2_08012007

    Document Title:Installer’s Guide ZZSENSAL0800AA
    Publication Type:Installation
    Publication Date:2007-08-01
    Installer’s GuideZZSENSAL0800AA ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES Remote Indoor Temperature Sensor( Use with *CONT800 Series Comfort Controls) 18-HD30D2-2 APPLICATIONThis Wall Mount Temperature Sensor is used with*CONT800 Series Comfort Controls
  • Media type icon

    18-CH87D1-1D_10282022

    Document Title:Installer's Guide Steam Humidifier EHUMD800ASM00BA / EHUMD800BSMLCBA
    Publication Type:Installation
    Publication Date:2022-10-28
    (distance minimale du tube de dispersion en amont de toute obstruction ou courbe dans le conduit) Capacité de l’humidificateur (litres/jour) Vélocité du débit d’air* 21 °C et valeur de réglage de 30 % d’HR 21 °C et valeur de réglage de 45 % d’HR 18 °C et valeur de réglage de 45 % d’HR Valeur de
  • Media type icon

    MUA-PRC010C-EN_08122020

    -PRC010C-EN • Evaporative Cooling with standard 8 inch or optional 12 inch media (203 or 305 mm). • Standard 18-gauge Cabinets, Painted Gray. • Standard 20-gauge Aluminized Steel Heat Exchanger. • Standard 1 inch Washable Filters. • Standard Single Stage Combination Gas Valve. • Standard High
  • Media type icon

    22-1919-1D-EN_06112020

    Product Data22 Series Split System (R-410A)Multi-Zone, Inverter System 18,000 to 42,000 BTU/Hr 22-1919-1D-EN Multi-Zone Outdoor UnitHeat Pump 4TXM2218A12N 4TXM2221A13N 4TXM2224A14N 4TXM2230A15N 4TXM2236A15N 4TXM2242A15N 4TXM6536A1040, , 4TXM6524A1030, 4TXM6530A1040 4TXM6542A1050 2 3 It's Hard to
  • Media type icon

    WSHP-PRC037C-EN_06082025

    with InsulationD = 1.5-inch Riser with InsulationE = 2-inch Riser with InsulationF = 2.5-inch Riser with InsulationG = 3-inch Riser with Insulation2 = 1-inch Riser3 = 1.25-inch Riser4 = 1.5-inch Riser5 = 2-inch Riser6 = 2.5-inch Riser7 = 3-inch Riser 18 WSHP-PRC037C-EN Digits 32 — Return Riser 0 = No
  • Media type icon

    PKGR-SVX003C-EN_10062025

    Document Title:Single Packaged Heat Pump, Choice, Convertible, 2 - 5 Ton, R-454B, 5WCC4
    Publication Type:Installation
    Publication Date:2025-10-06
    5WCC4042 1000.13[39.38] 457.20 [18]75.41[2.97] 75.41[2.97] 381.00[15] 244.09[9.61] 318.75[12.55] 381.00[15] 79.50[3.13] 449.02[17.68] 176.07[6.93] 322.84[12.71] 372.82[14.68] 1402.34[55.21] 5WCC4048 5WCC40601050.93[41.38] Dimensional Data 16 PKGR-SVX003C-EN Table 5. Weights and center of gravity
  • Media type icon

    CLCH-SVX018C-EN_12012025

    use of ignition sources in spaces. Thestandard may require a unit refrigerant leak detectionsystem.For equipment with either: A2L Information and Installation Requirements 18 CLCH-SVX018C-EN • R-454B and charge amounts less than or equal to 3.91lbs per circuit • R-32 and charge amounts less than or
  • Media type icon

    TEMP-SVX007C-EN_06302025

    overfill. The dipstick is attached to the filler cap. Installation Considerations 18 TEMP-SVX007C-EN • Coolant: Engine coolant must be above the ADD mark with antifreeze protection of-34°C (-30°F). Check and add coolant inthe expansion tank. • Battery: Terminals must be clean. Electrolyte should be at
  • Media type icon

    RT-SVX095C-EN_08182025

    UNIT LEFT VIEW OF UNIT FAN MANUAL DAMPER HOOD 123 1/8” 18 1/4” 26 7/8” 24 7/8” 12 13/16” 86 15/16” Dimensional Data RT-SVX095C-EN 17 WeightsTable 1. Maximum unit and corner weights (lb) and center of gravity dimensions (in.) Tons Unit ModelNo. Weights (lb)(a) , (b) Corner Weights(c) Center of Gravity