    BCX-SVX003D-EN_12052025

    . . . . . . . . . . 147 Table of Contents 8 BCX-SVX003D-EN Model Number Description Digit 1, 2, 3, 4 — Unit Model BCHE = Horizontal Blower CoilBCVE = Vertical Blower Coil Digit 5, 6, 7 — Unit Size 012 = Unit size 12 - 1 Ton018 = Unit size 18 - 1.5 Ton024 = Unit size 24 - 2 Ton036 = Unit size 36 - 3 Ton048 = Unit size 48
  • Media type icon

    18-GJ91D1-1B-EN_07172023

    Document Title:Installer's Guide Hydronic Heater Relay Kit BAYWACNTKT05, 07, 08, 11. For use with communicating TAMX or 5TAMX air handlers with BAYWA hydronic heaters
    Publication Type:Installation
    Publication Date:2023-07-17
    installation must comply with NATIONAL, STATE AND LOCAL CODES 18-GJ91D1-1B-EN Model:BAYWACNTKT05BAYWACNTKT07BAYWACNTKT08BAYWACNTKT11 3. General InformationThis kit includes a wire harness, a relay and a resis-tor that announces the size of the heater. The kit is for use with the TAMX or 5TAMX air
  • Media type icon

    18-GJ18D1-1A-EN_08032020

    Document Title:Installer's Guide Supply Duct Flange Kit (BAYSUPFLGAA, BAYSUPFLGBA, BAYSUPFLGCA) for Hyperion and ForeFront Air Handlers
    Publication Type:Installation
    Publication Date:2020-08-11
    INSTALLER'SGUIDE IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES 18-GJ18D1-1A-EN Fits Models: HyperionTM and
  • Media type icon

    18-CH80D1-3B-EN_09062022

    Document Title:Installer's Guide Manufactured Housing Accessory Kit BAYMFGH200C for S-Series, Ameristar, and RunTru Furnaces ONLY.
    Publication Type:Installation
    Publication Date:2022-09-06
    used only with the S-Series, Ameristar, and RunTru furnaces. Applies to model numbers that start with S9 or A9. 18-CH80D1-3B-EN ss WARNING! ss WARNING! INSTALLER'S GUIDE ss WARNING! SAFETY WARNING This kit must be installed by a qualified technician possessing adequate backgrounds of electrical and
  • Media type icon

    12134367_C_05222023

    Document Title:CONTROLS SCHEMATIC; 20-75T REF SYSTEM #1, EC MOTORS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-05-22
    3162KF35 MODULE - COMPRESSOR 1A PROTECTION 3212M6 CONDENSER FAN MOTOR 1A 3342M7 CONDENSER FAN MOTOR 1B 3362M8 CONDENSER FAN MOTOR 1C 3372QM9 SOLENOID - HOT GAS BYPASS 3032S2 SWITCH - HIGH PRESSURE CUTOUT 317,321,328 RBKBLGY GYBLBKR 1XP52 2XP54 1KF2-XP2 REDREDREDREDREDRED 1XJ46 1XJ46 1XJ46 1KF4-XP2
  • Media type icon

    12134361_B_07192022

    Document Title:IPAK 1 POWER SCHEMATIC 90-130T REFRIGERATION POWER LOW AMBIENT
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-07-19
    - CONDENSER FAN 1B 931QA13 CONTACTOR - CONDENSER FAN 1C / 1D 961QA15 CONTACTOR - CONDENSER FAN 2B 921QA16 CONTACTOR - CONDENSER FAN 2C / 2D 961QA40 CONTACTOR - CONDENSER FAN 1E / 1F 1041QA41 CONTACTOR - CONDENSER FAN 2E / 2F 1041S20 FUSED SWITCH - 115V CONTROLS 1201T8 TRANSFORMER - 115V CONTROLS 115 1TB4
  • Media type icon

    18-HD27D1-2A-EN_07062020

    Document Title:Installer’s Guide Outdoor Thermostat Kit
    Publication Type:Installation
    Publication Date:2020-07-30
    to change design and specifications without notice. We are committed to using environmentally conscious print practices. © 202018-HD27D1-2A-EN 06 Jul 2020 Supersedes 18-HD27D1-2 (February 2009) OUTDOOR THERMOSTAT INSTALLATION IN CONTROL BOX From Dwg. 21B152851 Rev.0
  • Media type icon

    12134997B_06132024

    Document Title:POWER SCHEMATIC, 40T-75T - REFRIGERATION
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-06-13
    CIRCUIT BREAKER - COMPRESSOR 2B 861QA6 CONTACTOR - COMPRESSOR 1A 781QA7 CONTACTOR - COMPRESSOR 1B 811QA9 CONTACTOR - COMPRESSOR 2A 841QA10 CONTACTOR - COMPRESSOR 2B 861QA11 CONTACTOR - CONDENSER FAN 1A 891QA12 CONTACTOR - CONDENSER FAN 1B 921QA13 CONTACTOR - CONDENSER FAN 1C 971QA14 CONTACTOR
  • Media type icon

    12135000B_06132024

    Document Title:POWER SCHEMATIC, 40T-75T - REFRIGERATION WITH COMPRESSOR AND COND FAN VFD
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-06-13
    - COMPRESSOR 2B 861QA7 CONTACTOR - COMPRESSOR 1B 801QA9 CONTACTOR - COMPRESSOR 2A 84 1QA10 CONTACTOR - COMPRESSOR 2B 861QA12 CONTACTOR - CONDENSER FAN 1B 921QA13 CONTACTOR - CONDENSER FAN 1C 971QA15 CONTACTOR - CONDENSER FAN 2B 1051QA16 CONTACTOR - CONDENSER FAN 2C 1101TB3 COMPRESSOR - VFD 761TB4
  • Media type icon

    12134998B_06132024

    Document Title:POWER SCHEMATIC, 40T-75T - REFRIGERATION WITH COMPRESSOR VFD
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-06-13
    - COMPRESSOR 2B 861QA7 CONTACTOR - COMPRESSOR 1B 801QA9 CONTACTOR - COMPRESSOR 2A 84 1QA10 CONTACTOR - COMPRESSOR 2B 861QA11 CONTACTOR - CONDENSER FAN 1A 891QA12 CONTACTOR - CONDENSER FAN 1B 921QA13 CONTACTOR - CONDENSER FAN 1C 971QA14 CONTACTOR - CONDENSER FAN 2A 1021QA15 CONTACTOR - CONDENSER FAN 2B