Search Results: 18-HD83D1-5B-EN

Showing 501 - 510 of 7,117 results

Display results per page.
  • Media type icon

    18-HE48D1-5A-EN_07082020

    Document Title:Crankcase Heater - (BELLYBAND STYLE) BAYCCHT301RES and BAYCCHT302RES use with- SCROLL COMPRESSORS (208 - 230V)
    Publication Type:Installation
    Publication Date:2020-07-15
    18-HE48D1-5A-EN Crankcase Heater(Bellyband Style) For Scroll Compressors (208-230V) BAYCCHT301RES60-watt heater for scroll compressors 6.5 - 7.5 in. diameter BAYCCHT302RES40-watt heater for scroll compressors 5.5 in. diameter Installer’s Guide ALL phases of this installation must comply with
  • Media type icon

    18-CH27D1-1A-EN_07172024

    Document Title:KIT07611, White - Rodgers Pressure Tap Adapter Kit
    Publication Type:Installation
    Publication Date:2024-07-17
    Installer’s Guide ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODESIMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work. 18-CH27D1-1A-EN KIT07611White - Rodgers Pressure Tap
  • Media type icon

    5719-3885B_11152024

    Document Title:Field Layout, CGAM Refresh, Slant Units
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-11-15
    . ACROSS LINE STARTER CIRCUIT 1 15. ACROSS LINE STARTER CIRCUIT 2 16. CHILLED WATER PUMP FAULT (6F1 AND 6F2) 17. EVAP WATER PUMP RUN SIGNAL 18. PHASE PROTECTION INPUT (6K1 AND 6K2) 19. REFER TO CGAM ELECTRICAL SCHEMATIC FOR SPECIFIC CONNECTION 20. INFORMATION AND NOTES PERTAINING TO WIRING INSTALLATION. 21
  • Media type icon

    88-MACC019-1A-EN_02022022

    Document Title:Installer's Guide Full Perimeter Roof Mounting Curb MAYCURB003A
    Publication Type:Installation
    Publication Date:2022-02-02
    88-MACC019-1A-EN Full Perimeter Roof Mounting CurbMAYCURB003A Installer’s Guide Used with 4 - 5 Ton Double Deck Gas Units Only ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT — This Document is customer property and is to remain with this unit. Please
  • Media type icon

    VAV-PRC011AF-EN_10312025

    8 0.2 0.4 0.8 1.6 2.4 3 3.4 3.7 3.8 3.6 10 0.3 0.5 1 1.8 2.5 3.1 3.5 3.8 3.9 3.4 12 0.5 0.9 1.5 2.5 3.2 3.8 4.4 5 5.3 5.1 14 0.7 1.4 2.3 3.3 3.9 4.4 5.2 6 6.5 6.1 16 0.9 1.6 2.7 3.8 4.3 4.9 5.7 6.8 7.5 7.2 Single-Duct VAV Terminal Units 18 VAV-PRC011AF-EN Table 8. Single duct (VCWF) 1/2-row coil
  • Media type icon

    ODR-PSD020A-EN_06252025

    ODR-PSD020A-EN_06252025 June 2025 ODR-PSD020A-EN 18 TruComfort™™ Variable Speed Air Conditioners5TTV8X24A1000A/B5TTV8X36A1000A/B5TTV8X48A1000A/B5TTV8X60A1000A/B TM The Diagnostics Mobile App is available by scanning a QR codeabove, the one located inside this unit or by searching for theTrane or
  • Media type icon

    BAS-SVX46E-EN_03182020

    /output wires; failure tocomply may cause the expansion module to malfunction due to electrical noise. • 18 AWG copper wire is recommended for the circuit between the transformer and theexpansion module. 12 BAS-SVX46E-EN XM30 and XM32 Module Power RequirementsThe XM30 and XM32 expansion modules are
  • Media type icon

    22-1871-09-EN_06092020

    Product Data Split System (R-410A)Multi-Zone, Inverter System 18,000 to 42,000 BTU/Hr 22-1871-09-EN Multi-Zone Outdoor UnitHeat Pump 4TXM6518A1 4TXM6524A1 4TXM6530A1 4TXM6536A1 4TXM6542A1 4TXM6518A1020 4TXM6536A1040, , 4TXM6524A1030, 4TXM6530A1040 4TXM6542A1050 2 It's Hard to Stop a Trane
  • Media type icon

    UNT-PRC022H-EN_06302025

    OutletBottom Stamped Louver Fresh AirN/A OutletFront Duct Collar OutletFront Quad Grille, Front Bar Grille Fresh AirN/A Fresh AirN/A Fresh AirN/A InletBottom Stamped Louver InletBack Duct Collar or Stamped Louver General Data 18 UNT-PRC022H-EN Model E, Horizontal Recessed OutletFront Duct Collar
  • Media type icon

    TEMP-PRC003B-EN_05092025

    these pumps, see Trane Rental ServicesElectrical Cable Engineering Bulletin (CHS-PRB005*-EN) for more information on the rental cable. Table 1. Pig-tail cable size chart Pump MCACable Size Type-W 10 hp 18 12 awg 15 hp 25 12 awg 25 to 30 hp 43 8 awg 40 hp 65 6 awg 50 hp 75 6 awg 60 hp 90 4 awg 100 hp