Search Results: 18-HE125D1-1C-EN

Showing 371 - 380 of 7,117 results

Display results per page.
  • Media type icon

    18-HE73D1-3D-EN_07062023

    Document Title:Installer's Guide- Extreme Condition Mounting Kit BAYEXMK001, For Mounting on Full Perimeter Curbs.
    Publication Type:Installation
    Publication Date:2023-07-14
    18-HE73D1-3D-EN Installer’s GuideExtreme Condition Mounting KitBAYEXMK001 For Mounting on Full Perimeter Curbs ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service
  • Media type icon

    BAS-PRD039C-EN_05202020

    Document Title:Tracer® XM90 Expansion Module / Product Data Sheet
    Publication Type:Product Data
    Publication Date:2020-05-20
    Tracer® XM90 Expansion Module Product Data Sheet May 2020 BAS-PRD039C-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific
  • Media type icon

    SSA-PRC006-EN_12012014

    Document Title:Illusion Concealed Type Minisplit Air Conditioners 12,000 - 60,000 Btu/h MCD Series 50 / 60 Hz / Product Bulletin
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2014-12-01
    1.25 / 1.53 cfm (cmh) 1490 (2532) 1600 (2717) 1600 (2717) 1600 (2717) No. of Blade 4 4 4 4 Fins per inc 14 18 18 18 SSA-PRC006-EN 17 General Data General Data TTK 60 Hz POWER CONNECTION V/ph/Hz 200-240/1/60 200-240/1/60 200-240/1/60 200-240/1/60MCA1, 3 SYSTEM DATARefrigerant Type R-22 R-22 R-22 R
  • Media type icon

    ACC-SVN57N-EN_04232020

    Document Title:Power Exhaust Kit - Standard and Low Leak Economizers 6 to 10 Tons
    Publication Type:Installation
    Publication Date:2020-04-23
    allowable waiting periods for discharge of capacitors. Verify with an appropriate voltmeter that all capacitors have discharged. For additional information regarding the safe discharge of capacitors, see PROD-SVB06*-EN. 1. Remove 6P7 plug from actuator module. 2. Using 18 ga. red quick splice connectors
  • Media type icon

    18-CH86D1-1A-EN_07202020

    Document Title:Installer's Guide Slim Fit Filter Box Kit for S-Series Furnace BAYSF1165AA
    Publication Type:Installation
    Publication Date:2020-07-29
    INSTALLER’SGUIDE ss WARNING! 18-CH86D1-1A-EN ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES For S-Series FurnaceBAYSF1165AAA - SV92xxxAxxxUxx; SV92xxxBxxxUxx; SV92xxxCxxxUxx;SV92xxxDxxxUxx Slim Fit Filter Box Kit: IMPORTANT—This Document is customer property and is
  • Media type icon

    ODR-SVX029A-EN_03202026

    a qualified licensed electrician orother individual who has been properly trained inhandling live electrical components perform thesetasks. Electrical 18 ODR-SVX029A-EN The high voltage power supply must agree with theequipment nameplate.Power wiring must comply with national, state, and
  • Media type icon

    18-AH68D1-1E-EN_07152020

    Document Title:Installer's Guide Horizontal Conversion Kit for 4PXC*U and 4PXC*D Conversions
    Publication Type:Installation
    Publication Date:2020-07-27
    removing sealing plugs. If no pressure is released, check for leaks. 18-AH68D1-1E-EN 2 18-AH68D1-1E-EN Installer’s Guide CAUTION!Caution: This coil is pressurized with 8-12 psig of dry air. Do not stand directly in front of the coil connections when removing sealing plugs. If no pressure is released
  • Media type icon

    UH-PRC002P-EN_07012022

    in excess of 2,000 ft. (610m) are to be ignored. At altitudes of 2,000 ft to 4,500 ft (610 m to 1372 m), the unit must be field derated, and be so marked in accordance with the ETL certification. (a) ODP = Open Drip Proof; SP = Shaded Pole; PSC = Permanent Split Capacitor 18 UH-PRC002P-EN Performance
  • Media type icon

    AH-PRC010A-EN_01082020

    (Pressure Drop, ftH2O) 29 (12) 32 (10) 39 (9) 40 (12) 50 (11) 70 (20) 80 (14) 103 (18) Table 5. Performance/Capacity data — TR-CFD/TR-CFF 45oF EWT/0% glycol (continued) Model TR-CFD/TR-CFF- 060-C1 090-C1 120-C1 150-C1 180-C1 190-C1 230-C1 280-C1 14 AH-PRC010A-EN Performance Data Table 6. Performance
  • Media type icon

    18-CD19D7-29-EN_09012016

    Document Title:Installer's Guide - Upflow/Horizontal Downflow/Horizontal, Gas-Fired Furnaces, Fan Assisted Combustion System Models: AUD1, TUD1, ADD1, TDD1
    Publication Type:Installation
    Publication Date:2016-09-01
    18-CD19D7-29-EN Upflow / Horizontal — Downflow / Horizontal, Gas-Fired Furnaces, “Fan Assisted Combustion System” Installer’s Guide Upflow / Horizontal* Downflow / Horizontal* For VENT SIZING INFORMATION see:USA —National Fuel Gas Code ........ ANSI Z223.1/NFPA 54 (latest version) CANADA — Natural