Search Results: TEMP-SLB008-EN

Showing 331 - 340 of 7,117 results

Display results per page.
  • Media type icon

    SO-SVN035A-EN_10132023

    Document Title:CVRF - Symbio™ Chiller Controller Retrofit Replacement Panel UCP1
    Publication Type:Installation
    Publication Date:2023-10-13
    Cooling 1 1 LonTalk® 1 Generic BAS 2 WiFi Mobile App 1 Air-Fi BACnet via Zigbee 1 LTE 4G Modem 1 Table 4. Field installed LLIDs for various options (continued) DBI DHVBI DBO HPRO QRO DAIO LON IGV PS 475 PSI Temp Sensor PS 0 to 50 or 475 PSIStarter Module Color Display WiFi AirFi LTE 8 SO-SVN035A-EN
  • Media type icon

    AFDG-SVU01L-EN_05122020

    Frequency 38AFD Surge Capacity Increase 1Tracer® TU Status View: MotorAverage Line CurrentStarter Average Phase VoltageStarter Load Power FactorMotor Winding #1 tempMotor Winding #2 tempMotor Winding #3 temp 38 AFDG-SVU01L-EN Recommended Periodic Maintenance and Inspection Visual Inspection—Power Removed
  • Media type icon

    PKGR-SVX010B-EN_10062025

    Document Title:Installation and Operations Manual - Single Packaged Heat Pump, Entry, Convertible, 2-5 Ton, A5PH
    Publication Type:Installation
    Publication Date:2025-10-06
    -SVX010B-EN 31 Using the chart in Table 11, p. 31, locate (as close aspossible) the actual sensor temperature. The measuredresistance should be relatively close to the resistance valueshown in the chart.Table 11. Defrost control thermistor table Temp °F Temp °CThermistorResistance(Ohms) Vo (Volts
  • Media type icon

    1213-1532B_11082016

    Document Title:Foundation Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2016-11-08
    CONTROL BOX 11 HTB2 TERMINAL BLOCK - ELECTRIC HEAT 4,7 HTRA HEATER 15 HTRB HEATER 19 TCO1 TEMP CUTOUT 17 TCO2 TEMP CUTOUT 18 TRANE FILE NUMBER: DRAWING NUMBER: SHEET: REV 12131529 12131532 1OF1 BTHIS DRAWING IS PROPRIETARY AND SHALL NOT BE COPIED OR ITS CONTENTS DISCLOSED TO OUTSIDE PARTIES WITHOUT THE
  • Media type icon

    BAS-PTS002A-EN_11082024

    Symbio™ 700 Integration Points ListLonTalk®Precedent® and Axiom™ Rooftop WSHP Date:11/08/2024Firmware Release: V7.00.0011 Reference Document: BAS-SVP086*-EN Profile Definition and Network Variables The following tables are sorted as follows: • Tables are listed by unit/profile type and sorted by
  • Media type icon

    BAS-PTS004A-EN_09182024

    Document Title:Symbio™ 800 Integration Points List LonTalk® for IntelliPak™
    Publication Type:Points List
    Publication Date:2024-09-18
    Symbio™ 800 Integration Points ListLonTalk®IntelliPak™ Date: 09/18/2024Firmware Release: 62000663-4-10-0002Reference Document: BAS-SVP084*-EN Profile Definition and Network Variables The following tables are sorted as follows: • Tables are listed by unit/profile type and sorted by network variable
  • Media type icon

    RT-SVX45F-EN_04022020

    Document Title:Packaged Rooftop Air Conditioners Precedent™ with eFlex™ Technology, Electric/Electric 3 to 10 Tons - 60 Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-04-02
    nuts to the two (2) field supplied wires that were connected to terminals 1 and 2 on J6. RT-SVX45F-EN 49 Troubleshooting Table 8. Fault detection and diagnostic codes Primary Fault Codes Information Code Failures Mixed Air Temp Sensor Fail Outdoor Temp Sensor Fail Economizer Actuator Fault RTEM Comm
  • Media type icon

    WSHP-SVX024B-EN_12012025

    Document Title:Water Source Heat Pump Axiom™ Variable Speed – VSH/VSV
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-12-01
    anti-freeze solution having a freezing point20°F lower than the minimum expected enteringtemperature. 50 WSHP-SVX024B-EN Table 34. Operating pressures in cooling/heating - VSH Model No. Cooling Heating EnteringWater Temp (°F) Water Flow(GPM) SuctionPressure,PSIG DischargePressure(PSIG) Water TempRise
  • Media type icon

    RT-SVX37C-EN_04022020

    Document Title:Packaged Rooftop Air Conditioners Precedent™- Electric/Electric 5 – 10 Tons – 50 Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-04-02
    Discharge AirSensing Tube14 8 Novar Return Air Sensor (NOVAR 2024)15,29 9 Novar Zone Temp Sensor (NOVAR 3051)18,29 A Condensate Drain Pan OverflowSwitch B Clogged Filter Switch14 andCondensate Drain Pan OverflowSwitch RT-SVX37C-EN 5 Model Number Descriptions C Fan Failure Switch14 and CondensateDrain Pan
  • Media type icon

    OAU-SVX01L-EN_06262023

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Discharge Air Temp. Reset for Single Zone VAV 85 Supply Fan Tracking for Exhaust Fan (Field En-abled) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Hot Water Reheat . . . . . . . . . . . . . . . . . . . 85 Expanded Fallback