Search Results: THER-IN-33C

Showing 2,121 - 2,130 of 3,327 results

Display results per page.
  • Media type icon

    22-1819-04_06012009

    electric heaters • Primary and secondary drain connections • Easy Air-TiteTM access to coils • Built-in indoor fan delay function for in-creased efficiency • 4TEE3C01 airflow selectable for 1-1/2 — 3 ton O.D. unit • 4TEE3C02-05 airflow selectable for 2 — 3-1/2 ton O.D. unit • 4TEE3C06-10 airflow
  • Media type icon

    18-CH64D1-1A-EN_07062020

    Document Title:Service Installer's Guide - KIT16433 Foil Insulation Repair Kit: For 5 Ton Variable Speed, 21" Wide cabinet, furnace models: *UD2C100A9V5 and *UD100R9V5K with serial numbers: 6010***** to 12251*****
    Publication Type:Installation
    Publication Date:2020-07-30
    experience. Any attempt to repair a central air conditioning product may result in personal injury and/or property damage. The manufac-turer or seller cannot be responsible for the interpreta-tion of this information, nor can it assume any liability in connection with its use. ss WARNINGSAFETY
  • Media type icon

    18-CH46D1-2_08012009

    Document Title:Installers Guide Two Stage Integrated Furnace Control for Furnaces with Variable Speed Fan CNT05141
    Publication Type:Installation
    Publication Date:2009-08-01
    ▲ CAUTION! To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete. This control is not intended for use in locations where it may come in direct contact with water. Suitable protection must be
  • Media type icon

    EDU-SLB045-EN_07112025

    Document Title:Energy Strategies for Campus Challenges
    Publication Type:Sales Brochure
    Publication Date:2025-07-11
    Energy Strategies for Campus ChallengesYour better tomorrow starts today. As a leader in higher education, you face multiple challenges including rising costs, tightening budgets, and increasing competition. These challenges call for innovative approaches—Trane can help. Enrollment & Recruitment
  • Media type icon

    CDS-SLB020-EN_02062026

    Document Title:TRACE™ The Next-Generation of Energy Modeling
    Publication Type:Sales Brochure
    Publication Date:2026-02-06
    TRACE™ The Next-Generation of Energy ModelingTRACE™ For more than fifty years, TRACE has supported industry professionals with trusted solutions in load design, energy modeling, and economic analysis software. Building on this legacy, we now offer the first-phase release of the new TRACE platform
  • Media type icon

    BAS-PTS033A-EN_12062024

    read-only or read/write. For BACnet®, the binary input, analog input and multi-state input points are all read-only. These setpoints report the value currently in use by the controller. The analog value, binary value and multi-state value points are all read/write. These points are provided for use
  • Media type icon

    88-MACC017-1A-EN_02052020

    Document Title:Installer's Guide Outdoor Thermostat Kit TAYSTAT250C
    Publication Type:Installation
    Publication Date:2020-01-01
    -ENAvailable in French Canadian (FC) GENERAL - SUPPLEMENTARY HEATER STAGING The outdoor thermostat (ODT) is designed to turn “ON” the supplementary heater at a pre-selected outdoor temperature. The number and setting of the ODT is dependent on the heat loss of the structure and capacity of the
  • Media type icon

    34-4054-08_08012008

    Document Title:40 in Residential Gas Furnace Operation Sold in Pkgs. of 5
    Publication Type:Installation
    Publication Date:2008-08-01
    ics | Igni tion Sys tem s | S erv i ce/T roub lesh oot i ng 1 Preface Air Conditioning and heating service techniciansmust have a working knowledge of basic electrical andrefrigeration service procedures. In order to servicegas furnaces, a thorough understanding of the unitssequence of operation is
  • Media type icon

    1213-4851B_09112024

    PPF116 BK BK R R BL BL O O Y Y BR BR PPM1 17 BKR BK BK R R O O BL BL Y Y BR BR BK PPM116123456789 10 1234 BKRBLBKRBLOBKRBL 445A (BL) 446A (GY) P5 J1212 BKR DAT PPM1 77 OAS PPM1 32 PPM19 SHS FOS PPM1 50 SYMBIO 700 MODBUS + MODBUS - COMMON COMMON 24 VAC-P OUT IMC+IMC- 24 VAC-P IN COMMON COMMON COMMON 24
  • Media type icon

    12134926B_02282024

    CHAIN VARIES BASED ON UNIT CONFIGURATION. SEE SHEET 5 FOR OPTIONAL WIRING PERTAINING TO YOUR CONFIGURATION. COMMON COMMON COMMON COMMON COMMON CIRCUIT 1 DISABLE REHEAT DISABLE IN FROSTAT IN OPTIONALMZVAV (UC) 12 12 PPF7812 12 12 12 12 12 12 12 PPF13212 12 12 TO AB-P20SHEET 4 TO AB-P20SHEET 4 TO AB