Search Results: TEMP-PRC012A-EN

Showing 201 - 210 of 7,122 results

Display results per page.
  • Media type icon

    RT-PRC125A-EN_09152024

    -PRC125A-EN 27 Table 10. Gross cooling capacities 25 tons — E/GDK300A3,4,W CFM EntDB (°F) Ambient Temperature (°F) Ambient Temperature (°F) Ambient Temperature (°F) 85 95 105Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) 61 67 73 61 67 73 61 67 73MBh SHC MBh SHC
  • Media type icon

    RT-PRC023AY-EN_12202022

    capacity3. SHC = Sensible heat capacity 40 RT-PRC023AY-EN Table 11. Gross cooling capacities 4 tons standard efficiency — three phase T/YSC048G3,4,W CFMEnt DB(°F) Ambient Temperature (°F) Ambient Temperature (°F) Ambient Temperature (°F) 85 95 105Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp
  • Media type icon

    FNR-PSD016A-EN_07012025

    Upflow / Horizontal Left/Right and Dedicated Downflow Single Stage Condensing Gas Fired Furnace July 2025 FNR-PSD016A-EN Upflow / Horizontal Left/Right and Dedicated DownflowSingle Stage Condensing Gas Fired Furnace Upflow, Convertible toHorizontal Right or
  • Media type icon

    MS-SVN056C-EN_02202018

    Document Title:U-Match Systems (R410A) 18,000 to 60,000 BTU/h - 60 Hz / Installation Manual
    Publication Type:Installation
    Publication Date:2018-02-20
    -SVN056C-EN 63 Wiring Diagrams Outdoor Unit - Cooling Only - 4TTK05-D (48K) - 1 Phase N1 POWER INPUT WHITE BLUE BLACK WHITE RED RED YELLOW RE D BLA CK BLACK BR OW N RED YELLOW WHITE BLUE CT1 H-RPO K1 BLA CK OR ANG E XT1XT2 XT6 L N S Y/G COMPR 21 C 22 CN100-208 P.C.BOARD SOCKETS TEMP. PROTECT SWITCH PIPE
  • Media type icon

    SSP-PRC023V-EN_01122025

    Data SSP-PRC023V-EN 35 Table 19. Gross cooling capacities (MBH) 6 tons TWA0724*A condensing unit only (IP) Outdoor Temp(°F) Saturation Suction Temperature (°F) 30 35 40 45 50 55 65 Head Press (psig) 265.1 271.6 278.5 285.6 293.0 300.7Capacity (Btuh/1000) 68.9 75.5 82.6 90.1 98.2 106.9Unit Power (kW
  • Media type icon

    18-GJ37D1-6A-EN_08042020

    Document Title:Installer's Guide Top Mount Hydronic Coil Accessory Fits Hyperion and ForeFront Air Handler Models BAYWACC11SC1AA
    Publication Type:Installation
    Publication Date:2020-08-11
    NATIONAL, STATE AND LOCAL CODES 18-GJ37D1-6A-EN Model:BAYWACC11SC1AA Table of ContentsSection 1. Safety Considerations.........................2Section 2. General Information ............................3Section 3. Hydronic Coil Assembly .....................4Section 4. Install Hydronic Coil
  • Media type icon

    ODR-SVX002C-EN_04172026

    or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. April 2026 ODR-SVX002C-EN Condensing
  • Media type icon

    AC-SVX004D-EN_05162025

    828 Water connection in. 4 4 4 4 4 4 4 4 4 General Information AC-SVX004D-EN 13 Table 3. General data – ACX (I-P) (continued) Max initial water temp at start-up(cooling) °F 105 105 105 105 105 105 105 105 105 Max chilled water setpoint (cooling) °F 68 68 68 68 68 68 68 68 68Max hot water setpoint
  • Media type icon

    AH-SVX015A-EN_04082023

    Document Title:Installation, Operation, and Maintenance CyberRow DX
    Publication Type:Installation Operation and Maintenance
    Publication Date:2023-05-06
    SETAlarm Set TemperatureSetpoint 72.0°FControlling toAvg supply air tempSTATUS---------------------Temp: 73.0°F Set:72.0°FDew: 50.3°F HumiditySet Point 45.0% STATUS________________Hum: 45.7% Set:45.0%Dew: 51.9°F 32 AH-SVX015A-EN E² Controller Saving and Restoring Setpoint Parameters Upon initial start
  • Media type icon

    22-1814-13_03012017

    Document Title:Trane Product Data - Upflow/Horizontal Left, Downflow/Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace XV95 Models TUH2-A9V, TDH2-A9V
    Publication Type:Product Data
    Publication Date:2017-03-01
    TUH2 PRODUCT SPECIFICATIONS1 Product Specifications 1 MODELTYPERATINGS 21st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 32nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3AFUE (Upflow / Horizontal)Temp. rise (Min.-Max.) °F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in