    PART-SVN117A-EN_08012009

    Document Title:Installation - Conversion to Trane TR200 from ATV58 or ATV66 Commercial Self Contained
    Publication Type:Installation
    Publication Date:2009-08-01
    0.75 thread rolling 3 X20030175040 1 Grommet edge extrusion 4 X19100029450 4 Bushing; 2” ID 5 507106530100 1 Mounting bracket 6 506892880100 2 Barriers 7 507106320100 1 Cover plate 8 X25020237010 4 Screw; #8-32 X 0.5 9 X28060232020 4 Locknut; #8-32 10 X22080028090 6 Lockwasher; #10 X22080028120 16
  • Media type icon

    PART-SVN120A-EN_05012009

    Document Title:Installer's Guide - Thrust Bearing Assembly CVHE, CVHF, CVHG - Non-Extended Capacity Compressors
    Publication Type:Installation
    Publication Date:2009-05-01
    Diameter (2.16” Bore) BRG01641(a) 2.1656” to 2.1661”7318 Large Diameter (3.54” Bore) BRG01642(a) 3.5435” to 3.5440”Note: These ceramic bearings are only used on the AFDE (LF2.0) Adaptive Frequency Drive equipped machines to prevent EDM (electrical discharge machining) failure to the bearings. (a) These
  • Media type icon

    PART-SVN124C-EN_05052020

    Document Title:Ceramic Bearing Replacement for CVHE and CVHF CenTraVac Chillers / Installation Instructions
    Publication Type:Installation
    Publication Date:2020-05-05
    Magnetic M-116 Cores Qty=5 X19210282010 Cable Ties 27 in. Qty=3 X20600036020 Trim-Lok Flexible Edging Qty=2 @ 7 in. each Mounting Hardware 3 Bolts, 3 Nuts KIT15646 X05010210010 Horizontal Mount Shelf Bracket, Rockwell Automation Frame 4 Qty=1 X13640735010 Magnetic M-117 Cores Qty=8 X19210282010 Cable Ties
  • Media type icon

    PART-SVN193B-EN_05222020

    Document Title:Field Service Kit CenTraVac Chiller Oil Tank Relay / Installation Instructions
    Publication Type:Installation
    Publication Date:2020-05-22
    should have their venting improved by adding 8–10 holes in the bottom of the box using a 0.25-in. drill bit. Seal the edges of the holes with paint. • Newer production units will have slots in the bottom of the terminal box, these newer units do NOT need their venting to be improved. Figure 9
  • Media type icon

    PART-SVN215B-EN_05222020

    Document Title:Replacement Economizer CenTraVac Chillers / Installation Instructions
    Publication Type:Installation
    Publication Date:2020-05-22
    contact with liquid refrigerant could result in minor to moderate injury. CAUTION Sharp Edges! The service procedure described in this document involves working around sharp edges. To avoid being cut, technicians MUST put on all necessary Personal Protective Equipment (PPE), including gloves and arm
  • Media type icon

    18-AC51D5-5-ES_01012010

    Document Title:Instrucciones de Instalación Unidad Condensadora 50 Hz Lang-Spanish
    Publication Type:Installation
    Publication Date:2010-01-01
    rolled edge. (SeeFigure 4) No torque is required. BRASS GAS LINE BALL SERVICE VALVEThe Brass Gas Line Ball Service Valve is shipped in theclosed position to hold the factory refrigerant charge. Thepressure tap service port (when depressed) opens only to thefield brazing side when the valve is in the
  • Media type icon

    18-AC52D1-5_01012010

    Document Title:Installers Guide Condensing Units 2TTB0
    Publication Type:Installation
    Publication Date:2010-01-01
    should be exercised when opening theLiquid Line Service Valve. Turn valve stem counterclock-wise only until the stem contacts the rolled edge. (SeeFigure 4) No torque is required. BRASS GAS LINE BALL SERVICE VALVEThe Brass Gas Line Ball Service Valve is shipped in theclosed position to hold the
  • Media type icon

    18-AC52D5-5_01012010

    Document Title:Installer’s Guide Condensing Units 2TTB0512-536A1 and 2TTB0512-536AA
    Publication Type:Installation
    Publication Date:2010-01-01
    counterclock-wise only until the stem contacts the rolled edge. (SeeFigure 4) No torque is required. FLARE FITTINGS 1. Remove gas and liquid line flare nuts from service valvesand discard copper caps. 2. Cut and fit tubing minimizing the use of sharp 90 degreebends, for a even flare it is recommended
  • Media type icon

    18-AD60D2-2_09012001

    Document Title:Installers Guide Cased Coils
    Publication Type:Installation
    Publication Date:2001-09-01
    configuration. This model is a direct expansion refrigerant (R22) coil as-sembly in an insulated sheet metal enclosure. The coil as-sembly is equipped with two thermal expansion valves(TXV), an evaporator defrost control switch (EDC), a built-indrain pan and a Heat Pump bypass/check valve
  • Media type icon

    18-AH47D1-2_07012010

    Document Title:Installer's Guide Replacement Coils Includes all coil models COL16255 through COL16291, COL16559, COL16760, COL16761 Kit numbers BAYCOIL55, 56, 57, 58, 59, 71, 72, 73, 74, 75, 78, 79, 80, 83
    Publication Type:Installation
    Publication Date:2010-07-01
    for the interpretation of this information, nor can it assume any liability in connec-tion with its use. Extreme caution should be exercised when opening the Liquid Line Service Valve. Turn counterclockwise until the valve stem just touches the rolled edge. No torque is required.LIVE ELECTRICAL