Search Results: TEMP-PRC012A-EN

Showing 171 - 180 of 7,122 results

Display results per page.
  • Media type icon

    PKGP-PRC021D-EN_09302023

    accordance with AHRI 370-2015. For additional information reference the outdoor sound power level data in the performance section. General Data 22 PKGP-PRC021D-EN Gross Cooling CapacitiesTable 7. Gross cooling capacities — 12.5 tons CFMEnt DB(°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp
  • Media type icon

    FNR-PSD015A-EN_07012025

    Upflow/Downflow/Horizontal Gas-Fired, 1–Stage Non-Condensing Induced Draft Furnaces with High Efficiency Motor July 2025 FNR-PSD015A-EN A801X040BM2SDBA801X060BM4SDBA801X080BM4SDBA801X080CM5SDBA801X100CM5SDBA801X120DM5SDB Notes: • Graphics in this document are for representationonly. Actual model
  • Media type icon

    RT-PRC078H-EN_12032022

    table notes.2. MBh = Total gross capacity3. SHC = Sensible heat capacity RT-PRC078H-EN 19 Table 4. Gross cooling capacities 4 tons - E/GBC048A3,4,W,K CFM EntDB (°F) Ambient Temperature (°F) Ambient Temperature (°F) Ambient Temperature (°F) 85 95 105Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F
  • Media type icon

    RLC-SVX09T-EN_10312025

    Condenser Leaving Hot Water TempControl1 = Condenser Leaving Hot Water Temp Control RLC-SVX09T-EN 9 Digit 36 — Power Meter 0 = No Power MeterE = Energy Meter Digit 37 — Motor Current Analog Output (%RLA)0 = No Motor Current Analog Output1 = Motor Current Analog Output Digit 38 — A/C Fan Control 0 = No
  • Media type icon

    BAS-SVN234A-EN_06102023

    , 24 VAFor specifics on transformer sizing, see BAS-SVX090*-EN. Mounting Weight of Controller: Mounting surface must support 0.80lb. (0.364 kg) Environmental Rating (Enclosure): NEMA 1 Plenum Rating Not plenum rated Dimensions/Mounting/Removing Symbio 500 To mount device:1. Hook device over top of
  • Media type icon

    SO-SVU001A-EN_10132023

    AFD Surge Capacity Increase 1 Tracer TU Status View: Motor Average Line Current Starter Average Phase Voltage Starter Load Power Factor Motor Winding #1 temp Motor Winding #2 temp Motor Winding #3 temp SO-SVU001A-EN 51 Start-Up Test Log Water-Cooled CenTraVac Chiller with CH530/CH531 Control and
  • Media type icon

    RT-PRC128A-EN_01122025

    sea level. General Data 18 RT-PRC128A-EN Performance DataGross Cooling CapacitiesTable 5. Gross cooling capacities 7.5 tons CFMEntDB (°F) Ambient Temperature (°F) Ambient Temperature (°F) Ambient Temperature (°F) 85 95 105Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp
  • Media type icon

    ACC-SVN173F-EN_09152024

    Document Title:CO2 Sensing Kit Foundation™ Packaged Rooftop Units 3 to 5 & 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    CO2 Sensing KitFoundation™ Packaged Rooftop Units3 to 5 Tons15 to 25 Tons Installation Instructions September 2024 ACC-SVN173F-EN Model Numbers: Used With: BAYCO2K300*, ASYSTAT900* Foundation Wall Mounted SensorBAYCO2K301*, ASYSTAT901* Foundation Duct Mounted Sensor SAFETY WARNINGOnly qualified
  • Media type icon

    BAS-SVP061C-EN_01102026

    Document Title:Symbio™ 400–B/500 Programmable Controller For Water Source Heat Pump
    Publication Type:Integration Guide
    Publication Date:2026-01-10
    installed, adjusted or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. January 2026 BAS-SVP061C-EN Integration
  • Media type icon

    ACC-SVN205E-EN_08232024

    August 2024 ACC-SVN205E-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed