    FNR-PSD011B-EN_02232026

    . - Max.) °F 25 - 55 30 - 60 25 - 55 25 - 55 2nd Stage Temp. Rise (Min. - Max.)°F 40 - 70 40 - 70 30 - 60 35 - 65 Product Specifications 10 FNR-PSD011B-EN Table 3. Models S9X2C100U5PSBB, S9X2D120U5PSBB, S9X2B040D3PSBB, and S9X2B060D3PSBB (continued) Model Number S9X2C100U5PSBB S9X2D120U5PSBB
  • Media type icon

    PKGP-PRC023D-EN_09122025

    Document Title:Precedent™ Packaged Rooftop Units
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-09-12
    -lowNOx. (l)Ultra-lowNOxgasfurnaceoptionnotavailableforH ighAltitudeinstallations above2000 feet. General Data PKGP-PRC023D-EN 41 Gross Cooling CapacitiesTable 10. Gross cooling capacities — 3 tons standard efficiency, heat pump CFMEntDB (°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F
  • Media type icon

    DHWHP-PRC001A-EN_07132025

    Document Title:Domestic Hot Water Heat Pump
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-07-13
    performance 4.1 Recovery rate(g) 1991 Gal/hr Mechanical Specifications 28 DHWHP-PRC001A-EN Table 32. T810WMmechanical specifications (continued) Unit Specifications Single Pass Multi Pass Compressor type Scroll Refrigerant R513A Factory charge 38.5 lbs. x 3 Max water temp 175°F Max working pressure
  • Media type icon

    RT-PRC123B-EN_03092025

    -PRC123B-EN 43 Table 14. 30 ton high efficiency, gross cooling capacities (Mbh)—60 Hz CFMEnt DB(°F) Ambient Temperature (°F) Ambient Temperature (°F) Ambient Temperature (°F) 85 95 105Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) 61 67 73 61 67 73 61 67 73TGC SHC
  • Media type icon

    PART-PRC012A-EN_10312025

    23.6 2123.5 11.2 10 PART-PRC012A-EN Nominal Performance DataPerformance data valid only for standard volume ratio designs (model number digit 15-E). CapacityTable 5. Capacity (btu/hr) — voltage 460-60-3 Compres-sor CondTemp Deg °F Evaporator Temp Deg °F -25 -10 0 10 20 30 40 45 50 60 70 80 CSHE071
  • Media type icon

    1213-2219C_08312016

    Document Title:Foundation Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2016-08-31
    101 1 2 3 LTB2 101AF(BL),101AG(BL) 101AU(W) 8 4 1 5 2 3 6 4 EER1 101AU(W)162A(BK) 164A(BK) 163A(BK) LEGEND DEVICE DESIGNATION DESCRIPTION CCH CRANKCASE HEATER CO2 CO2 SENSOR COF CONDENSATE OVERFLOW SWITCH CPR COMPRESSOR DISC SINGLE POINT DISCONNECT DTL SWITCH - DISCHARGE TEMP LIMIT ECA ECONOMIZER
  • Media type icon

    1213-2218C_08312016

    Document Title:Foundation Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2016-08-31
    101 1 2 3 LTB2 101AF(BL),101AG(BL) 101AU(W) 8 4 1 5 2 3 6 4 EER1 101AU(W)162A(BK) 164A(BK) 163A(BK) LEGEND DEVICE DESIGNATION DESCRIPTION CCH CRANKCASE HEATER CO2 CO2 SENSOR COF CONDENSATE OVERFLOW SWITCH CPR COMPRESSOR DISC SINGLE POINT DISCONNECT DTL SWITCH - DISCHARGE TEMP LIMIT ECA ECONOMIZER
  • Media type icon

    RT-SVX091B-EN_03092025

    ) Outdoor RH (%) Suction Line Pressure (PSI) Sat. Temp (°F) Temp (°F) Superheat (°F) Liquid Line Pressure (PSI) Sat. Temp (°F) Temp (°F) Subcooling (°F) Evaporator Leaving Temp (°F) WSHP OnlyEntering Water Temp (°F) Leaving Water Temp (°F) Water Coil Pressure Drop (PSI) RT-SVX091B-EN 67 Start-Up Form
  • Media type icon

    CG-SVX063D-EN_08152025

    -EN 49 Figure 35. Water piping components B UNIT CUSTOMER PIPING 2 1 24 3 36 6 7 5 8 5 5 Table 26. Water piping components Item Description Item Description 1 Bypass Valve Pi Gauge 2 Isolation Valves FT Water Flow Switch 3 Vibration Eliminators T1 Evap Water Inlet Temp Sensor 4 Evaporator Heat
  • Media type icon

    PKGP-PRC021D-EN_09302023

    Document Title:Packaged Rooftop Air Conditioners Precedent™ Heat Pump High Efficiency 12.5 to 25 Tons — 60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2023-09-30
    accordance with AHRI 370-2015. For additional information reference the outdoor sound power level data in the performance section. General Data 22 PKGP-PRC021D-EN Gross Cooling CapacitiesTable 7. Gross cooling capacities — 12.5 tons CFMEnt DB(°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp