Search Results: TEMP-PRC012A-EN

Showing 131 - 140 of 7,122 results

Display results per page.
  • Media type icon

    ODR-SVX022B-EN_04172026

    cleared. Defrost Control ODR-SVX022B-EN 29 c. Ambient sensor failure will initiate an adaptive timedlimp mode. This will be accompanied by a 1 flash.The DFC will initiate defrost after 60 minutes ofaccumulated heating runtime and force a defrost,which will terminate on coil temp. The limp modewill
  • Media type icon

    FNR-PSD001A-EN_07012025

    – L8V1A060U3VSL8V1A060U3VS Furnace Heating Airflow (CFM), Temp. Rise (°F), and Power (Watts) vs. External Static Pressure (iwc) with Filter Airflow Setting External Static Pressure0.1 0.3 0.5 0.7 0.9 830CFM/Watts 856/50 849/101 843/153 836/204 829/255Temp. Rise 51 51 52 52 53 FNR-PSD001A-EN 9 Table 6. Heating
  • Media type icon

    SS-PRC049A-EN_08112024

    indoorfan heat. 2. kW = Total Gross Capacity, SHC = Sensible Heat Capacity Performance Data 42 SS-PRC049A-EN Table 25. Gross cooling capacities (MBH) TWA0604*A condensing unit only (IP) Outdoor Temp(°F) Saturation Suction Temperature (°F) 30 35 40 45 50 55 65 Head Press (psig) 259.1 265.4 271.9 278.8 285.8
  • Media type icon

    RT-PRC020-EN_02012003

    Document Title:Package Two Stage Gas - Electric Units Convertible Models YCZ036,050,060F1,3, 4, 5 Ton
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2003-02-01
    =SENSIBLE CAPACITY)TOTAL CAPACITY, COMP. KW AND APP. DEW PT.ARE VALID ONLY FOR WET COILALL TEMPERATURES IN DEGREES F. 22-1684-03-0203 (EN) 11 Performance DataCooling YCZ050F—A AT 1600 CFM(CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. TOTAL
  • Media type icon

    18-SG01D1-1A-EN_03012017

    Document Title:Trane - Installer's Guide Home Standby Generator Automatic Transfer Switch
    Publication Type:Installation
    Publication Date:2017-03-01
    connected. 718-SG01D1-1A-EN SpecificationsOutside Size : 495 x 375 x 180Operation Temp -20°C to 70°C (-4°F to 158°F)Storage Temp -40°C to 85°C (-40°F to 185°F)Humidity 5 to 95% cannot freezingWeight (Kg) 17.5 Controller DKG-173 SpecificationsGenerating voltage 170-300V-AC (Ph-N phase line-null line
  • Media type icon

    UH-SVX01A-EN_09032008

    Document Title:S and P Unit Heaters
    Publication Type:Installation Operation and Maintenance
    Publication Date:2008-09-03
    Rated Water Flow 25% 50% 75% 100% 125% 150% 175% Heating Capacity Factor .80 .89 .96 1.00 1.04 1.07 1.10 UH-SVX01A-EN 49 Hot Water Performance Data Table 35. P Type Standard Output Units** Model No. Water Temp. Drop °F (°C)Output MBH (kW)Flow Rate G.P.M. (L/s) Press. Drop ft/water (m/water) Final
  • Media type icon

    RT-SVX064C-EN_04302024

    – Enabled N Circuit 2 Reversing Valve(a) Disabled – Enabled N Condenser Fan Command(a) Disabled – Enabled N OA/RA Damper Position Command 0% – 100% N 34 RT-SVX064C-EN System Configuration and Pre-Start Reports (continued from previous page) System Setpoints DAT High Temp Cutout 100°F 125°F 150°F Y
  • Media type icon

    BAS-SVP18E-EN_07012022

    Document Title:Tracer® UC600 Programmable Controller Packaged Outdoor Air Unit
    Publication Type:Integration Guide
    Publication Date:2022-07-01
    installed, adjusted or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. July 2022 BAS-SVP18E-EN Integration GuideTracer®
  • Media type icon

    SO-SVN063A-EN_11162024

    Description3TS1 Temp Switch, AFD Enclosure Pin 1, 3B20 AFD Enclosure Fan 1TB5 9-16 115 V Neutral Pin 2, 3B20 AFD Enclosure Fan Installation – Electrical 36 SO-SVN063A-EN Circuit 2 Connections Table 14. 1U1 AFD, all units Terminal - AFD Description Mating Connection DescriptionPin 61 Modbus (RS485) Com
  • Media type icon

    TEMP-SVN010A-EN_05122024

    Document Title:Trane Rental Services
    Publication Type:Installation
    Publication Date:2024-05-12
    dehumidification. Figure 7. Sensor switch Figure 8. Sensor switch Heating/Cooling Setpoint Slide Bar System Switch Fan Selector Switch Start-Up Instructions Trane Rental ServicesRS*X00**F7 Precedent™ May 2024 TEMP-SVN010A-EN TEMP-SVN010A-EN 12 May 2024 (NEW) 13.If needed, adjust the Minimum Supply