    5071-2776A_08062021

    Document Title:CenTraVac® Schematic AdaptiView Panel Upgrade with Subpanel Danfoss Drive AFDH
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-08-06
    ! DAMAGE TO THE EQUIPMENT. N'UTILISER QUE DES CONDUCTEURS PAS CON荱ES POUR RECEVOIR D'AUTRES L'UTILISATION DE TOUT AUTRE CONDUCTEUR LES BORNES DE L'UNITÉ NE SONT TYPES DE CONDUCTEURS. EN CUIVRE! ATTENTION PEUT ENDOMMAGER L'蒕UIPEMENT. SI NO LO HACE, PUEDE OCASIONAR TILICE 贜ICAMENTE CONDUCTORES LAS
  • Media type icon

    PART-PRC012A-EN_10312025

    16.57 16.65 16.70 16.72 16.68 16.64 16.58 16.40 16.112 — 130 — 18.10 18.16 18.23 18.29 18.33 18.32 18.30 18.26 18.12 17.892 — 140 — 19.97 20.02 20.08 20.14 20.19 20.20 20.19 20.17 20.07 19.891 — 155 — — — — — — 23.527 23.532 23.527 23.477 — — Performance Data 18 PART-PRC012A-EN Table 7. Current (amps
  • Media type icon

    2309-4621R_05042022

    Document Title:RTAC Schematic, 3 Compressor Units, X-Line Starter
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-05-04
    CE OPTIONS (pg11) CAUTION PRECAUCIÓN ATTENTION AVERTISSEMENT ADVERTENCIAWARNING C TRANE RELEASED 04/May/2022 21:18:34 GMT AutoCAD SHX Text DASHED LINES INDICATE FIELD WIRING BY OTHERS. ALL UNIT POWER WIRING MUST BE COPPER CONDUCTORS ONLY AND HAVE A MINIMUM TEMPERATURE INSULATION RATING OF 90 DEGREE
  • Media type icon

    2309-4622R_05042022

    Document Title:RTAC Schematic, 3 Compressor Units, Y-Delta Starter
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-05-04
    CE OPTIONS (pg11) CAUTION PRECAUCIÓN ATTENTION AVERTISSEMENT ADVERTENCIAWARNING C TRANE RELEASED 04/May/2022 21:18:34 GMT AutoCAD SHX Text 4 AutoCAD SHX Text 5 AutoCAD SHX Text 6 AutoCAD SHX Text 7 AutoCAD SHX Text 8 AutoCAD SHX Text 9 AutoCAD SHX Text 10 AutoCAD SHX Text TABLE OF CONTENTS AutoCAD
  • Media type icon

    ODR-SVN006B-EN_08232025

    . Example of measuring refrigerant line Line Length 18 ODR-SVN006B-EN Refrigerant Line InsulationImportant: The vapor line must always be insulated. Do not allow the liquid line and vapor line to comein direct (metal to metal) contact. Note: The vapor line must always be insulated. Insulatingthe liquid
  • Media type icon

    DLR-SVN006B-EN_02252026

    Document Title:Side Discharge Heat Pump
    Publication Type:Installation
    Publication Date:2026-02-25
    values are given inTable 7, p. 16 for flare nut.e. Insert. Refrigerant Line Connections 18 DLR-SVN006B-EN Figure 21. Wrench using guide Braze the Refrigerant LineNote: A2L equipment shall have red marked service ports and pipes through which refrigerant is serviced.1. Remove caps or plugs. Use a
  • Media type icon

    BAS-SVX094A-EN_07142024

    Document Title:Symbio™ Communication Module (CM2)
    Publication Type:Installation Operation and Maintenance
    Publication Date:2024-07-14
    -SVX094A-EN DimensionsFigure 1. CM2 dimensions *One DIN unit = 18 mm*DIN Standard 43 880, Built-in Equipment for Electrical Installations, Overall Dimensions and RelatedMounting Dimensions Important: Slotted release clip shown– if removing or repositioning the controller, the user must removeconnectors
  • Media type icon

    18-GJ37D1-6A-EN_08042020

    Document Title:Installer's Guide Top Mount Hydronic Coil Accessory Fits Hyperion and ForeFront Air Handler Models BAYWACC11SC1AA
    Publication Type:Installation
    Publication Date:2020-08-11
    NATIONAL, STATE AND LOCAL CODES 18-GJ37D1-6A-EN Model:BAYWACC11SC1AA Table of ContentsSection 1. Safety Considerations.........................2Section 2. General Information ............................3Section 3. Hydronic Coil Assembly .....................4Section 4. Install Hydronic Coil
  • Media type icon

    BAS-SVX55J-EN_09152024

    WCI WCI WCI WCI The three networks (A,B,C) pictured here arejoined to one Tracer SC+ using three coordinators.The entire IMC comm link can be 200 meters in length. Network Design 18 BAS-SVX55J-EN Using Multiple Networks to Avoid ObstructionsAlways design networks keeping the building infrastructure
  • Media type icon

    SO-SVN020A-EN_08312023

    Document Title:Variable Frequency Drive Conversion TR1 to TR200 Commercial Self Contained Signature and Modular Series Units
    Publication Type:Installation
    Publication Date:2023-08-31
    SO-SVN020-EN.book Variable Frequency DriveConversion TR1 to TR200Commercial Self Contained Signature and Modular Series Units Installation Instructions August 2023 SO-SVN020A-EN Model Numbers: Units with factory installed VFDs and units with VFD or VFD with bypass options: S**F 20 to 110 tonsS**G