Search Results: ED*

Showing 1,131 - 1,140 of 1,420 results

Display results per page.
  • Media type icon

    WSHP-SVX024B-EN_12012025

    parties areadvised.Initial safety checks shall include:• Cabling is not subject to wear, corrosion, excessive pressure, vibration, sharp edges, or any other adverseenvironmental effects. Account for the effects of agingor continual vibration from sources such ascompressors or fans. • Capacitors are
  • Media type icon

    SO-SVN026C-EN_12052025

    back of the cabinet is level andlined up against the Z-bracket, then attach thecabinet to the bracket using the kit hardwareprovided (screws for the motor terminal access).Shims may be necessary to level the lowermounting bracket. The front edge of the evaporatorbrackets may need to be ground down to
  • Media type icon

    WSHP-SVG004A-EN_12072025

    Document Title:Water Source Heat Pump Axiom™ Variable Speed – Compressor Inverter
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-12-07
    . Loosen the two screws on the operation panel. (These screws cannot be removed.) Figure 3. Loosen screws 2. Press the upper edge of the operation panel whilepulling out the operation panel. Figure 4. Remove operation panel To reinstall the operation panel, align its connector onthe back with the PU
  • Media type icon

    CLCH-SVX021C-EN_12192025

    Document Title:Performance Climate Changer™ Fan Coil Wall for Data Centers
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-12-19
    anchors at 24 in. o.c. • 4 3/4-in. min. anchor embedment• 9-in. min. distance to the nearest edge• 8-in. min. concrete slab thickness b. On steel dunnage/steel curb:• 3/4-in. dia ASTM A325 or SAE grade 5 bolts at 24 in. o.c. or• 1-in. long 3/16-in. welds at 24-in. o.c. 2. Stacked single-wide<164 in
  • Media type icon

    BAS-SVX092D-EN_01102026

    Document Title:Symbio™ 400–B/500 Programmable Controllers Water Source Heat Pump (WSHP)
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-01-10
    of the unit fan. The Symbio 400–B/500 controllercompares the fan run time against an adjustable Filter Runtime Hours Setpoint (AV/12), and recommends unit maintenance asrequired. The Tracer TU service tool is used to edit the maintenance required setpoint time. After exceeding the setpoint limit,the
  • Media type icon

    WSHP-SVX021C-EN_12132025

    Document Title:Water Source Heat Pump Axiom™ Rooftop
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-12-13
    include:• Cabling is not subject to wear, corrosion, excessive pressure, vibration, sharp edges, or any other adverseenvironmental effects. Account for the effects of agingor continual vibration from sources such ascompressors or fans. • Capacitors are discharged. This shall be done in a safemanner
  • Media type icon

    WSHP-PRC038B-EN_12132025

    Document Title:Water Source Heat Pump Axiom™ Rooftop
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-12-13
    requirements, and arecompetitively priced. Trane delivers with Axiom™ rooftop features.Axiom™ rooftop features cutting edge technologies: reliable compressors, Trane-engineered Symbio controls, computer-aidedrun testing, and Integrated Comfort™ Systems. So, whether you’re the contractor, the engineer, or the
  • Media type icon

    OAU-PRC008C-EN_12132025

    actions at 12 percent LFL of R-454B Advanced Controls • All controls are factory-engineered, mounted, configured and tested to minimize field start-up time• Symbio™ 500 BACnet® microprocessor control• Human interface with touch-pad screen for monitoring, setting, editing and controlling• Capable of
  • Media type icon

    OAU-SVX009A-EN_12132025

    touchscreen display will be included. The Tracer® TD-7 human interface allows for monitoring, setting, editing, and controlling the unit. The display can be mounted at the unit within the controls cabinet or remotely for ease of controls access without being at the unit. The TD-7 display is powered
  • Media type icon

    RT-SVX099A-EN_12132025

    is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment, so all parties are advised. Initial safety checks shall include: • Cabling is not subject to wear, corrosion, excessive pressure, vibration, sharp edges, or any