  • Media type icon

    BAS-SVP053A-EN_04162022

    Document Title:BACnet® Communication Interface for ReliaTel™ Controllers (BCI2-R)
    Publication Type:Integration Guide
    Publication Date:2022-04-16
    BBAASS--SSVVPP005533AA--EENN Integration Guide BACnet®® Communication Interfacefor ReliaTel™™ Controllers (BCI2-R) ©2022 Trane BAS-SVP053A-EN IntroductionThe BACnet Communication Interface for ReliaTel (BCI2-R) supportsTrane ReliaTel rooftop unitsthat function as part of a BACnet MS/TP communications
  • Media type icon

    SSA-PRC006-EN_12012014

    Document Title:Illusion Concealed Type Minisplit Air Conditioners 12,000 - 60,000 Btu/h MCD Series 50 / 60 Hz / Product Bulletin
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2014-12-01
    Performance Data 24 SSA-PRC006-EN Fan Performance Data SSA-PRC006-EN 25 Fan Performance Data TTK509LB5 WITH MCD009AA5 26 SSA-PRC006-EN OUTDOOR I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR.D.B. W.B. CAP. 72 74 76 78 80 KW 61 9.7 7.6 8.3 8.9 9.5 9.9* 0.67 8565 10.5 6.3 7.0 7.6 8.2 8.9 0.7067 10.9 5.6
  • Media type icon

    FNR-SVX005A-EN_05292026

    Document Title:Upflow/Horizontal and Dedicated Downflow Gas-Fired, Direct/Non-Direct Vent, 2-Stage Condensing Variable Speed Furnaces A952V
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-05-29
    USED AND THE VOLTAGE SUPPLIED TO THE FURNACE. THE ACCEPTABLE RANGE IS 0.75-3 MICROAMPS. DEPENDENT Figure 5. Ladder diagram – A952V FNR-SVX005A-EN 19 Heating and Cooling Airflow TablesTable 6. A952V040BU3S heating airflow Furnace Heating Airflow (CFM), Power (Watts), and Temp. Rise (°F) vs. External
  • Media type icon

    MCX5-PRC804-EN_11011998

    Document Title:Stylus Mini-Split System Air Conditioning, 1 - 5 Tons Convertible Models, 50 Hz. Models- MCX512EB, MCX518EB, MCX524EB, MCX536EB, MCX042EB, MCX048EB, MCX060EB (Indoor Units)
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:1998-11-01
    MCX5-PRC804-EN PerformanceDataCooling TTB515CA WITH MCX518EBAT 475 CFM GROSS CAPACITY IN BTU/H x 1000O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. DEWD.B. W.B. CAP. 72 74 76 78 80 KW DEW PT. 59 13.4 12.0 12.9 13.6* 14.0* 14.3* 1.01 48.685 63 14.6 10.2 11.1 12.1 13.0 14.0 1.05 52.3 67 15.8
  • Media type icon

    PART-PRC009A-EN_04252025

    Document Title:R-410A Scroll Compressor Model CSHD 6.2 to 15.3 Tons
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-04-25
    183,441 16,560 25.2 2,707 11.08 575-60-3 – – – – – Performance Data PART-PRC009A-EN 11 Nominal Performance DataPerformance data valid only for standard volume ratio designs (model number digit 12 = M). CapacityTable 4. Capacity (btu/hr) — voltage 200-60-3 ComprSize CSHDxxx CondTemp °F Evaporator Temp °F
  • Media type icon

    ODR-SVX003D-EN_04172026

    10238 0.63 80.00 26.67 9065 0.57 85.00 29.44 8043 0.52 90.00 32.22 7150 0.47 95.00 35.00 6368 0.42 100.00 37.78 5682 0.38 105.00 40.56 5079 0.35 110.00 43.33 4548 0.31 ODR-SVX003D-EN 27 Table 8. Defrost control thermistor (continued) Temp °F Temp °CThermistorResistance(ohms) Volts DC 115.00 46.11 4079
  • Media type icon

    BAS-SVP085B-EN_11152024

    Document Title:BACnet® and Modbus ™ Integration
    Publication Type:Integration Guide
    Publication Date:2024-11-15
    . If the Heat Cool Mode Status is Cool then the Symbio™ 700 controller will use the Space Temp Cooling Setpoint Status.7. If the Heat Cool Mode Status is Heat then the Symbio™ 700 controller will use the Space Temp Heating Setpoint Status. Appendix A: Arbitrations 24 BAS-SVP085B-EN Space Temperature
  • Media type icon

    COR-SVN006B-EN_05012026

    Document Title:Installer's Guide - Replacement Coils
    Publication Type:Installation
    Publication Date:2026-05-01
    (Yellow, if equipped) Evap Temp(Orange) Coil Installation for DownflowApplications1. Slide the replacement coil into the unit. See Figure 25, p. 17.Note: Some modifications to the unit or return air duct work may be required for downflow applications. Installation COR-SVN006B-EN 17 Figure 25
  • Media type icon

    ODR-SVX009B-EN_04172026

    40.56 5079 0.35 110.00 43.33 4548 0.31 ODR-SVX009B-EN 29 Table 9. Defrost control thermistor (continued) Temp °F Temp °CThermistorResistance(ohms) Volts DC 115.00 46.11 4079 0.28 120.00 48.89 3665 0.26 125.00 51.67 3298 0.23 130.00 54.44 2972 0.21 135.00 57.22 2683 0.19Example: Sensor temp. = 19°F
  • Media type icon

    18-GJ21D1-2B-EN_08212024

    , STATE AND LOCAL CODES 18-GJ21D1-2B-EN Models:BAYWA1705SC1AABAYWA2107SC1AABAYWA2308SC1AA Table of ContentsSection 1. Safety Considerations ...... 2Section 2. General Information .......... 3Section 3. Hydronic Coil Assembly .. 4Section 4. Install Hydronic Coil ......... 5Section 5. Piping