Search Results: 18-CH94D1-1C-EN

Showing 961 - 970 of 7,136 results

Display results per page.
  • Media type icon

    PART-SVN155B-EN_05182020

    Document Title:Location of Parts - Motor Change Out Kit, KIT16334, Model Numbers: CVHG / Installation Instructions
    Publication Type:Installation
    Publication Date:2020-05-18
    residentialapplications. For more information, please visit trane.com or tranetechnologies.com. PART-SVN155B-EN 18 May 2020 Supersedes PART-SVN155A-EN (Jun 2012) 6Table 2. 565 Compressor 050 Shells Part numbers referenced in Figure 4 Figure 4. Refer to Table 2 for part location and use Part # Qty. Location and Use Ref
  • Media type icon

    ODR-SVX004D-EN_04172026

    follow instructions below could result indeath or serious injury, and property damage.Confirm the cabling is protected from wear and tear,corrosion, excessive pressure, vibration, sharpedges, and any other adverse environmental effects. Electrical 18 ODR-SVX004D-EN System Start-Up1. Confirm that
  • Media type icon

    CLCH-SVX010E-EN_08152024

    GasketGasket 18 CLCH-SVX010E-EN Installation - Mechanical Figure 18. Wall section assembly Add caulking afterinstalling J strip #8 x 1-in. Phillips zip screw2 3/4-in. wide joining strip Wall split 4-in. x 1/4-in. gasketAdd caulking beforeinstalling J strip Wall panel section split 2 3/4-in. wide joining strip
  • Media type icon

    WSHP-PRC038B-EN_12132025

    Document Title:Water Source Heat Pump Axiom™ Rooftop
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-12-13
    need service. Use only manufacturer-approved sensors when replacement is required. Application Considerations 18 WSHP-PRC038B-EN Model Number Description Digit 1 — Function G = Rooftop WSHP Digit 2 — Efficiency S = Standard Efficiency Digit 3 — Refrigerant K = R-454B Digit 4, 5, 6 — Nominal Gross
  • Media type icon

    BAS-PTS016A-EN_11152024

    Symbio™ 800 Integration Points ListLonTalk®Series R® Model RTHD Date:11/15/2024Reference Document: BAS-SVP084*-EN Profile Definition and Network Variables The following tables are sorted as follows: • Tables are listed by unit/profile type and sorted by network variable number.• Tables are sorted
  • Media type icon

    RT-SVX091B-EN_03092025

    15000 Over15000 Amin Adjustment 1 1.05 1.11 1.17 1.24 1.32 1.41 1.51 1.57 18 RT-SVX091B-EN A2L Information In addition, Amin can be adjusted if the unit is installed in a room at a height that is higher than the minimum height shown on the unit. To adjust Amin, multiply by the ratio of the unit minimum
  • Media type icon

    PART-SVN236B-EN_06172020

    Document Title:Model H and L Compressors Mineral and POE Oil
    Publication Type:Installation
    Publication Date:2020-06-17
    Available Digit 18 — Sight GlassC = No Selection Available Digit 19 — Seal Type0 = No Selection Available 6 PART-SVN236B-EN Warranty Implications Trane warranties do not apply if any refrigerant other than Trane design approved refrigerants are used in the product application. For example, a mineral
  • Media type icon

    SO-SVN036B-EN_12132024

    Document Title:CVRF - Symbio™ 800 Chiller Controller Retrofit Replacement Panel UCP2
    Publication Type:Installation
    Publication Date:2024-12-13
    Damage!Failure to follow instruction below could result in equipment damage. Never route low-voltage leads with other conductors carrying 30 or more volts. Installation 18 SO-SVN036B-EN bypass or Enhanced Protection packages were ordered and are to be installed. 8. Bearing temperature sensors: inboard
  • Media type icon

    RSP-PRC022-EN_06012005

    Document Title:Refrigeration Specialties By Emerson Climate Technologies Flow Controls Division
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2005-06-01
    R407C7½ (27) 9 (32) 10 (35) 8 (28) 8 (28) 10 (35)10 (35) 13 (46) 15 (53) 12 (42) 12 (42) 15 (53)12 (42) 14 (50) 20 (71) 14 (50) 14 (50) 20 (71)18 (64) 22 (78) 30 (106) 20 (71) 20 (71) 30 (106)25 (88) 30 (106) 40 (142) 30 (106) 30 (106) 40 (142) 29RSP-PRC022-EN Thermo Expansion Valves TRAE Thermo®
  • Media type icon

    HDWA-SVX002E-EN_05262025

    to be supervised toensure that they do not play with theappliance. 18 HDWA-SVX002E-EN NOTICEEquipment Damage!Failure to protect the unit from freezing could result inequipment damage.If fluid has been added to the piping, the unit must beprotected from freezing. Freeze damage from anunheated