Search Results: TEMP-SLB008-EN

Showing 711 - 720 of 7,117 results

Display results per page.
  • Media type icon

    1213-4993B_09242024

    Document Title:SCHEMATIC; SHEET 2, POWER, SINGLE INDOOR FAN, LOW NOX GAS HEAT, 230V HIGH SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-24
    105TNS4 TRANSFORMER - GAS HEAT 97VTL SWITCH - VESTIBULE TEMP LIMIT 92 GYGY YBR O/G O/G GYGY P8 P12 P10 1AB 2AB(O) 3AB(Y) PPF105 P11PPM166BKBKR ROO PPF167 BL BLBK PPF91 52C(Y) 52C(Y) 51B(O) 51B(O) PPF9151B(O) 51B(O) 52B(Y) 52B(Y) 54A(Y) 53A(O) P7 BLBL PPF109-SPPF109-B PPM103-BPPM103-R 137A (BR) 137A
  • Media type icon

    SYS-SLB039-EN_06272024

    Document Title:High Temperature Heat Pump Systems - Plugging HVAC innovation into new or existing buildings
    Publication Type:Sales Brochure
    Publication Date:2024-06-27
    applications. Contact your Trane Account Manager to learn more. Heating Distribution 150°F – 200°F (66°C – 93°C) Medium Temp Heat Source 60°F – 90°F (16°C – 32°C) Low Temp Heat Source 25°F – 60°F (4°C – 16°C) Heating Distribution Up to 200°F (93°C) RTWD Up to 180°F (82°C) CVHH Heat Source/Cooling Load 25°F – 60°F (4°C – 16°C) Heating Distribution Up to 200°F (93°C) RTWD Up to 180°F (82°C) CVHH
  • Media type icon

    1213-4994C_10232024

    Document Title:SCHEMATIC; SHEET 2, POWER, SINGLE INDOOR FAN, LOW NOX GAS HEAT, 460V HIGH SC
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-10-23
    - VESTIBULE TEMP LIMIT 92 GYGY YBR O/G O/G GYGY P8 P12 P10 1AB 2AB(O) 3AB(Y) PPF105 P11PPM166BKBKR ROO PPF167 BL BLBK PPF91 P7 BLBL PPF92 137A (BR) 137A 138A (O) 138A 139A (Y) 139A 140A(G/Y) PPM8912 BR (BR) BR O (O) O 141A(BR)142A(O)143A(Y) 144A(G/Y) BKR BR DRAI N FU36L2 T2 FU35L1 T1 PS TCO1 TCO2 FR
  • Media type icon

    CAUJ-SVX01G-EN_06242020

    Document Title:Split System Air-Cooled Condensers — 20 to 120 Tons
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-06-24
    HGBP No HGBP 20-60 40 30 10 0 80-120 40 10 0 Note: Minimum starting ambients in degrees F, based on unit at minimum step of unloading and 5 mph wind across condenser. SSttaarrtt--UUpp CAUJ-SVX01G-EN 51 Table22.Sam plemaintenancelog Date Current Ambient Temp. (°F) RefrigerantCircuit#1
  • Media type icon

    18-HD73D1-9E-EN_08102023

    Document Title:ComfortLink™ II XL 850 Communicating Connected Control, TCONT850 Installation Guide
    Publication Type:Installation
    Publication Date:2023-08-10
    18-HD73D1-9E-EN TCONT850 Installation Guide ComfortLink™ II XL 850Communicating Connected Control ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT — This Document is customer property and is to remain with this unit. These instructions do not cover all
  • Media type icon

    22-1919-1D-EN_06112020

    Product Data22 Series Split System (R-410A)Multi-Zone, Inverter System 18,000 to 42,000 BTU/Hr 22-1919-1D-EN Multi-Zone Outdoor UnitHeat Pump 4TXM2218A12N 4TXM2221A13N 4TXM2224A14N 4TXM2230A15N 4TXM2236A15N 4TXM2242A15N 4TXM6536A1040, , 4TXM6524A1030, 4TXM6530A1040 4TXM6542A1050 2 3 It's Hard to
  • Media type icon

    12134363_B_09012022

    Document Title:IPAK 1 CONTROLS SCHEMATIC 20-75T CUSTOMER CONNECTIONS #1
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-09-01
    EQUIPMENT STOP 24VDC24VDC24VDC J1 J11 ZONE SENSE J15 J4 J3 J2 J5 1KF10 GND (N) GND (N) GND (N) GND (N) GND (N) GND (N) SPACE HUMIDITY CHANGEOVER MODE INPUT ZONE TEMP HEAT SP COOL SP 24VDC24VDC24VDC J1 J11 ZONE CONTROL J15 J4 J3 J2 J5 901B(BK) 901B(BK) 902B(BK) 902B(BK) 900D(BK) 900D(BK) 903B(BK) 903B
  • Media type icon

    PROD-SLB049-EN_03162026

    comprehensive coverage. 5 Air-Cooled Chillers AC Portfolio Brochure Table OPERATING RANGE (leaving fluid range, ambient temp range) Solution Capacity Low GWP Refrigerant Compressor Technology Cooling Heating Trane® Air-Cooled Model CGAM 20-130T R-454B Scroll 0°F to 65°F; -20°F to 125 °F ambient Heat
  • Media type icon

    5071-2754B_10102021

    ! DAMAGE TO THE EQUIPMENT. N'UTILISER QUE DES CONDUCTEURS PAS CON荱ES POUR RECEVOIR D'AUTRES L'UTILISATION DE TOUT AUTRE CONDUCTEUR LES BORNES DE L'UNITÉ NE SONT TYPES DE CONDUCTEURS. EN CUIVRE! ATTENTION PEUT ENDOMMAGER L'蒕UIPEMENT. SI NO LO HACE, PUEDE OCASIONAR TILICE 贜ICAMENTE CONDUCTORES LAS
  • Media type icon

    RT-PRC053L-EN_12202022

    Document Title:Packaged Rooftop Air Conditioners Precedent™ with eFlex™ Technology — Cooling and Gas/Electric 3 to 10 Tons — 60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2022-12-20
    airflow, use the following formula: Temp. rise across Electric Heater = kW x 3414/1.08 x CFM. (a) The minimum allowable airflow for a 3 ton with a 17.4 kW heater is 1080 cfm.(b) The minimum allowable airflow for a 5 ton unit with a 23.0 kW heater is 1900 cfm. 86 RT-PRC053L-EN Heat Performance Table