    hp – 1800 rpm M = 3 hp – 3600 rpm N = 5 hp – 1800 rpm P = 5 hp – 3600 rpm 18 OAU-SVX008B-EN Model Number Descriptions Digit 34 — Filtration OptionsA = No FiltersB = MERV-8, 30%C = MERV-13, 80%D = MERV-14, 95%E = MERV-8 30%, MERV-13 80%F = MERV-8 30%, MERV-14 95%G = MERV-8, 30%, with UVCH = MERV-13
  • Media type icon

    WSHP-SVX016B-EN_09292023

    Document Title:Water Source Heat Pump Axiom™ Rooftop Standard Efficiency 12.5 to 25 Tons 60Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2023-09-29
    Oversized Motor – 30 Powered Convenience Outlet 50 50 Powered Exhaust 110 110 Reheat Coil 100 100 Dimensional Data 18 WSHP-SVX016B-EN Table 2. Factory installed options (FIOPS)/accessory net weights (lb) (continued) AccessoryGSJ150-180 GSJ240-30012.5, 15 Tons 20, 25 Tons Roof Curb 235 235 Smoke
  • Media type icon

    WSHP-SVN013A-EN_11202024

    Document Title:Roof Curb Axiom™ Rooftop Water Source Heat Pump 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-11-20
    Heat Pump3 to 5 Tons Model Numbers: Used With:FIACURB401* WSHPA cabinet (Digit 39 = A) with 14-inch curb FIACURB801* WSHPA cabinet (Digit 39 = A) with 18-inch curb ©2024 Trane WSHP-SVN013A-EN IntroductionRead this manual thoroughly before operating or servicingthis unit. Warnings, Cautions, and
  • Media type icon

    18-CH44D1-1A-EN_07172020

    Document Title:Installer's Guide - Kit 15182 Conversion Kit: Temperature Limit Switch
    Publication Type:Installation
    Publication Date:2020-07-30
    policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. © 202018-CH44D1-1A-EN 17 Jul 2020 Supersedes 18-CH44D1-1 (April 2008)
  • Media type icon

    SO-SVN032A-EN_10132023

    Document Title:CVRF - Symbio™ Chiller Controller Retrofit Replacement Panel Single Door Pneumatic
    Publication Type:Installation
    Publication Date:2023-10-13
    (PPE), in accordance with NFPA70E for arc/flash protection, PRIOR to entering the starter panel cabinet. 18 SO-SVN032A-EN Installation 2. Remove the existing pulse IGV actuator and existing conduit and wire. 3. Install the new IGV actuator on the chiller. a. Use the connecting hardware retained when
  • Media type icon

    MUA-SVX002C-EN_04112026

    Document Title:Outdoor Rooftop Evaporative Cooling Units For Heating, Cooling, and Ventilating Systems
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-04-11
    unit with evaporative cooling (with supply plenum) CAPACITY A B F(a) G ▲J(b)GAS INLET NAT LP 1032-7/8 15-9/16 19-3/8 31-1/16 24 1/2 1/2(835) (395) (492) (789) (610) 1532-7/8 18-5/16 23-1/2 31-1/16 24 1/2 1/2(835) (465) (597) (789) (610) Performance and Specification Data MUA-SVX002C-EN 11 Table 3
  • Media type icon

    AHR-SVN001A-EN_06192025

    heater data table values.• Updated literature number to replace 18–HB22D1-14C- EN. Introduction AHR-SVN001A-EN 5 GeneralThis accessory electric heater is designed to provide powerdirectly to the unit from the accessory heater's powersupply eliminating the need for additional circuits. Thepower and
  • Media type icon

    2311-5509E_11022021

    Document Title:Ascend Model ACR, 150 to 300 tons, Schematic Wiring
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-11-02
    INSET E 2C3U4 V4 W4 2K7 21 2K7 65 273A 262A 271A 263A 261A INSET EOPTIONAL HARMONIC FILTER - CIRCUIT 2 208A, 240A, 320A AND 403A INPUT INSET E DRIVEPANELGND DRIVEPANELGND 2RF2 U1 V1 W1 U2 V2 W2 U4 V4 W4GND 61A 7B 8B 9B 1Q1- 1LI NE 18 1Q1- 3LI NE 18 1Q1- 5LI NE 18 1B 2B 3B 1F38 2 1 4 3 6 5 1Q1- 1LI NE
  • Media type icon

    DOAS-PRC001N-EN_10312025

    Document Title:CoolSense™ Chilled Water Sensible Cooling Terminal Units
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-10-31
    . Size the valve for a Cv = 1/2 the GPM it must pass inmodulating applicationsThe equation that governs valve sizing is: Cv =GPM ∆P Where• Cv = Flow coefficient Application Considerations 18 DOAS-PRC001N-EN • GPM = The maximum water flow rate through the valve in gallons per minute• ΔP = The maximum
  • Media type icon

    ODR-PSD038A-EN_12132025

    Inverter Side Discharge HP December 2025 ODR-PSD038A-EN Inverter Side Discharge HP 5HCL5036B1000A5HCL5060B1000A Note: Graphics in this document are for representation only. Actual model may differ inappearance. Product and Submittal Data ©2025 ODR-PSD038A-EN IntroductionCopyright This document and