  • Media type icon

    5071-2755B_10102021

    ! DAMAGE TO THE EQUIPMENT. N'UTILISER QUE DES CONDUCTEURS PAS CON荱ES POUR RECEVOIR D'AUTRES L'UTILISATION DE TOUT AUTRE CONDUCTEUR LES BORNES DE L'UNITÉ NE SONT TYPES DE CONDUCTEURS. EN CUIVRE! ATTENTION PEUT ENDOMMAGER L'蒕UIPEMENT. SI NO LO HACE, PUEDE OCASIONAR TILICE 贜ICAMENTE CONDUCTORES LAS
  • Media type icon

    2311-1976C_03092022

    WITH FLOW SWITCHES. WHEN ORDERED THE OUTDOOR AIR TEMP SENSOR ELECTRONICS IS FACTORY MOUNTED INSIDE THE CONTROL PANEL AND THE IPC BUS ISFACTORY WIRED. THE SENSOR IS TO BE FIELD WIRED EXTERNALLY WITH THE SENSOR LEADS EXTENDED BACK TO THE CONTROLPANEL. THESE WIRES CAN BE SPLICED WITH TWO 14-18 AWG 600V
  • Media type icon

    18-GJ59D1-2_11012012

    Document Title:Installer's Guide - RS-485 Replacement Board Model: CNT06197.
    Publication Type:Installation
    Publication Date:2012-11-01
    BAYWACC08 w/*AM7A0C60, BAYWACC08 w/*AM7A0C60BAYWACC08 w/TAMGA0C60 ON ON OFF BAYWACC11SC1A w/*AM7A0C60 BAYWACC11SC1A w/*AM7A0C60BAYWACC11SC1A w/TAMGA0C60 ON ON ON * May be "A" or "T" HHCFault LED Description OFF No fault1 Internal communication error2 Water temp is at 38F or lower3 Water temp sensor
  • Media type icon

    PROD-SLB049-EN_03162026

    Document Title:Air-cooled Chillers - A Wide Range of Options for Sustainability, Efficiency, Acoustics and Beyond
    Publication Type:Sales Brochure
    Publication Date:2026-03-16
    comprehensive coverage. 5 Air-Cooled Chillers AC Portfolio Brochure Table OPERATING RANGE (leaving fluid range, ambient temp range) Solution Capacity Low GWP Refrigerant Compressor Technology Cooling Heating Trane® Air-Cooled Model CGAM 20-130T R-454B Scroll 0°F to 65°F; -20°F to 125 °F ambient Heat
  • Media type icon

    12134532_B_12122022

    Document Title:SCHEMATIC; SHEET 6 CONTROLS FRESH AIR OPTIONS STD ECON
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-12-12
    SENSOR - RETURN AIR TEMP 317SPC SOLENOID - SPACE PRESSURE CALIBRATION 334SPP TRANSDUCER - SPACE PRESSURE 325XFR CONTACTOR - POWER EXHAUST 317 FAOM-J9 PPM86 BK R BL OPPM68 PPF98 P9 RED 24 VDC OUT24 VDC OUTRETURN AIR TEMP INPUTRETURN AIR HUMIDITY INPUTOUTDOOR AIR HUMIDITY INPUTCOMMON P10 GRAY ANALOG
  • Media type icon

    2311-4166C_10112022

    Document Title:Vertical Unit Vent
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-10-11
    -2 AutoCAD SHX Text 24VAC J1-1 AutoCAD SHX Text COMM - J13-4 AutoCAD SHX Text COMM + J13-3 AutoCAD SHX Text TEMP SENSOR AIP1 J1-6 AutoCAD SHX Text 149 AutoCAD SHX Text 219 AutoCAD SHX Text 217 AutoCAD SHX Text 218 AutoCAD SHX Text 215 AutoCAD SHX Text 216 AutoCAD SHX Text 212 AutoCAD SHX Text 213
  • Media type icon

    57325334_A_10112023

    Document Title:Diagram; Unit Component Location, ACR, 3 and 4 Compressor
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-10-11
    ; MOTOR WINDING TEMP 1 - COMP. 1A 5BT2 SENSOR; MOTOR WINDING TEMP 2 - COMP. 1A 5L1SOLENOID; LEFT BERIABLE VI - COMP. 1A 5L2SOLENOID; RIGHT VARIABLE VI - COMP. 1A 6BP2SENSOR; DISCHARGE - CKT 2 5BP2SENSOR; DISCHARGE - CKT 1 6L7SOLENOID; UNLOAD VALVE -COMP. 2B 6L6SOLENOID; LOAD VALVE -COMP. 2B 5BT7SENSOR
  • Media type icon

    PKGP-SVX015E-EN_05152026

    Document Title:Precedent™ Packaged Rooftop Units
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-05-15
    , adjusted or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. May 2026 PKGP-SVX015E-EN Installation, Operation, and
  • Media type icon

    CG-PRC002E-EN_07012012

    Document Title:CGAD Liquid Chillers - Air-Cooled Scroll Compressor 20 to 150 Tons - Models- 50 and 60 Hz / Product Catalog / Sourced in Brazil
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2012-07-01
    Product Catalogue CG-PRC002E-ENJuly 2012 CGAD Liquid ChillersAir-CooledScroll Compressor20 to 150 Tons Models: 50 / 60 Hz CGAD020 CGAD040 CGAD070 CGAD100CGAD025 CGAD050 CGAD080 CGAD120CGAD030 CGAD060 CGAD090 CGAD150 2 CG-PRC002E-EN Introduction CGADAir-Cooled Liquid ChillersDesigned for great
  • Media type icon

    UNT-SVX07Q-EN_06302025