Search Results: 18-CH83D1-1B-EN

Showing 641 - 650 of 7,142 results

Display results per page.
  • Media type icon

    BAS-PRD068B-EN_08152024

    Document Title:Trane® Thermostats Programmable
    Publication Type:Product Data
    Publication Date:2024-08-15
    Trane® ThermostatsProgrammableData Sheet Product Data August 2024 BAS-PRD068B-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires
  • Media type icon

    ACC-SVN315A-EN_09152024

    Document Title:Roof Curb Precedent™ Packaged Rooftop Units
    Publication Type:Installation
    Publication Date:2024-09-15
    CLEARANCE 18" (457 MM) FOR HORIZONTAL Figure 2. Curb dimensional data 24 3/8"(916 MM) 14 1/16(375 MM) 16 3/16"(411 MM) 17 1/16"(433 MM) 14" (355 MM) IS FOR FIACURB401*18" (457 MM) IS FOR FIACURB801* ALL FLANGES 1 1/4" (32 MM) RETU RN SUPP LY 8 ACC-SVN315A-EN Installation Figure 3. Roof construction
  • Media type icon

    CG-PRC017AA-EN_04302026

    Document Title:Air-Cooled Scroll Chillers Model CGAM with Symbio™ Controls
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2026-04-30
    available head pressure is based on 6.7/12.2°C evaporator with water, .01761 m²°C/kW, 35°C ambient and 0 m elevation. General Data 18 CG-PRC017AA-EN ControlsSymbio 800 ControllerTrane chillers offer predictive controls that anticipate and compensate for load changes. Other strategies made possible with
  • Media type icon

    CLCH-SVX018C-EN_12012025

    use of ignition sources in spaces. Thestandard may require a unit refrigerant leak detectionsystem.For equipment with either: A2L Information and Installation Requirements 18 CLCH-SVX018C-EN • R-454B and charge amounts less than or equal to 3.91lbs per circuit • R-32 and charge amounts less than or
  • Media type icon

    RRU-SVX01F-EN_11012021

    Clearances Figure 8. Unit dimensional data 12.5-, 15-, and 20-ton high efficiency 18 RRU-SVX01E-EN Unit Weight/Rigging Rigging Refer to Figure 9 and Table 1 for typical unit operating weights rigging before proceeding. 3. Remove the shipping crate from around the unit. Do not remove the crating from the top
  • Media type icon

    18-CH79D1-5C-EN_05222024

    Document Title:Installer's Guide BAYLPSS400C Propane Conversion Kit for S-Series, Ameristar and RunTru Furnaces, and 4YCA Package Units
    Publication Type:Installation
    Publication Date:2024-05-22
    Burner D345196P021 Installer's Guide 18-CH79D1-5C-EN6 Orifice main burner #56 B138253P331 Propane Label B342003P121 Conversion Responsibility Label B342003P12 1Kit Spring Conversion (2 springs included) A729800P01 1Pressure Tap Adapter Kit (KIT07611) A342055P01 18-CH79D1-5C-EN C. CONVERSION INSTRUCTIONS
  • Media type icon

    18-HD27D1-2A-EN_07062020

    Document Title:Installer’s Guide Outdoor Thermostat Kit
    Publication Type:Installation
    Publication Date:2020-07-30
    to change design and specifications without notice. We are committed to using environmentally conscious print practices. © 202018-HD27D1-2A-EN 06 Jul 2020 Supersedes 18-HD27D1-2 (February 2009) OUTDOOR THERMOSTAT INSTALLATION IN CONTROL BOX From Dwg. 21B152851 Rev.0
  • Media type icon

    18-GH37D1-2A-EN_08032020

    Document Title:Installer's Guide - Downflow Water Management Kit BAYTEMDFKT1A for use with TEM3A0C60S51SA and TEM4A0C60S51SA
    Publication Type:Installation
    Publication Date:2020-08-11
    D804620P01 Downflow Gasket 43 A905049P04 Screw 10-16 x 5/8 64 A968011P01 Gasket - .25x1.0x26 25 D804590P01 Pan Retainer 26 D804392P09 Blower Insulation 17 A960031P16 Aluminum Tape 18 18-GH37D1-2A-EN Installer's Guide 1 KIT COMPONENTS - Refer to Figure 1 for part identification. Page 2 FIGURE 2 FIGURE 3
  • Media type icon

    COR-SVX001A-EN_08022025

    Document Title:Multi-Position Cased Coils with Leak Mitigation Kit Cooling
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-08-02
    SENSOR Figure 14. Refrigerant sensor connectionCN26 Note: After installing the sensor, add a zip tie to theincoming refrigerant sensor wire. Field Wiring DiagramsFigure 15. Field wiring diagram Note:Wiring diagram is applicable to Trane furnace applications. Installation 18 COR-SVX001A-EN Alarm
  • Media type icon

    KIT09418_08012006

    Document Title:KIT09418 KIT; AFD COVER GROUNDING, FOR USE WITH 440E MOTOR FRAME WITH LARGE BEARINGS
    Publication Type:Installation
    Publication Date:2006-08-01
    2/13/2004 1 EACHX22080031060 WASHER; SPRING STK RAW 2/13/2004 1 EACHX14080474020 DRILL BIT; 25/64, GENERAL PURPOSE, JOBBER BLACK STK RAW 2/13/2004 1 EACHPART-SVN79A -EN LITERATURE; MOTOR SHAFT GROUNDING SYSTEM STK RAW 2/13/2004 1 EACHX14080475010 TAP; PLUG HAND, 7/16-20 LH H3 3F F/S SERIES STK RAW