Search Results: 18-HE82D1-2B-EN

Showing 631 - 640 of 7,128 results

Display results per page.
  • Media type icon

    ODR-PSD029B-EN_02132026

    ODR-PSD029B-EN_02132026 February 2026 ODR-PSD029B-EN Multi-Speed Air Conditioners and Heat Pumpswith WeatherGuard™ featuring ComfortSeek™5TTX7024A5TTX7036A5TTX7048A5TTX7060A 5TWX7024A5TWX7036A5TWX7048A5TWX7060A Note: Graphics in this document are for representation only.Actual model may differ in
  • Media type icon

    RT-PRC095D-EN_04302024

    Qty Height Width 2 8, 13 2 20 24 2 8, 13 2 24 24 4 14 2 20 24 4 14 2 24 24 ERV Module Return Air Thickness MERV Qty Height Width 2 8 4 18 24 Outside Air Thickness MERV Qty Height Width 2 8 4 18 24 RT-PRC095D-EN 13 General Data Note: Filter inlet hood is only provided on units with electric preheater
  • Media type icon

    ODR-PSD019A-EN_06252025

    ODR-PSD019A-EN_06252025 June 2025 ODR-PSD019A-EN 20 TruComfort™™ Variable Speed Air Conditioners withWeatherGuard™™5TTV0X24A1000A/B5TTV0X25A1000A/B5TTV0X36A1000A/B5TTV0X48A1000A/B5TTV0X60A1000A/B Note: Graphics in this document are for representation only.Actual model may differ in appearance. TM
  • Media type icon

    RT-SVN045A-EN_07152021

    sensor can be added for Demand ControlVentilation (DCV) functionality. To configure the JADEcontroller, set the following parameters: SETPOINTS Menu: DCV SET = desired CO2 ppm to start DCV EEccoonnoommiizzeerr CCoonnttrroolllleerr 18 RT-SVN045A-EN VENTMAX = desired maximum position w/DCV &occupied status
  • Media type icon

    OAU-SVX008B-EN_03092025

    hp – 1800 rpm M = 3 hp – 3600 rpm N = 5 hp – 1800 rpm P = 5 hp – 3600 rpm 18 OAU-SVX008B-EN Model Number Descriptions Digit 34 — Filtration OptionsA = No FiltersB = MERV-8, 30%C = MERV-13, 80%D = MERV-14, 95%E = MERV-8 30%, MERV-13 80%F = MERV-8 30%, MERV-14 95%G = MERV-8, 30%, with UVCH = MERV-13
  • Media type icon

    MUA-SVX004B-EN_08132020

    Document Title:Outdoor Rooftop Gas-Fired Duct Furnace Natural or Power Vented / IOM
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-08-13
    ttoo uunniitt nnaammeeppllaattee aanndd iinnssttaallllaattiioonn iinnssttrruuccttiioonnss ffoorr pprrooppeerr cclleeaarraanncceess.. 16 MUA-SVX004B-EN Figure 6. Minimum Clearances to Combustible Material or Obstructions 18"(457)5/16" (8) Ductwork Natural(or Power) VentFurnace Air Flow 5/16"(8) 18
  • Media type icon

    VAV-SVN03K-EN_06122023

    Document Title:VariTrac™ Central Control Panel
    Publication Type:Installation
    Publication Date:2023-06-12
    , use 18 gage, 2 conductor cable forthe power wiring (TB1-TB1), and 18 gage, 3 conductor cable for signal wiring (TB2-TB3). Getting Started VAV-SVN03K-EN 31 Figure 15: Zone Temperature Sensor Controller Wiring Zone Temperature Sensor Wiring VAV-SVN03K-EN32 Communication Link WiringThe VariTrac
  • Media type icon

    UNT-PRC001AA-EN_02262026

    -PRC001AA-EN 11 Digit 18 — Main Coil (continued) 4 = Heat pump, Auxiliary electric heat6 = Electric preheat Digit 19 — Drain Pan 3 = Polymer drain pan4 = Stainless steel drain pan Digit 20 — Air Vent 0 = NoneA = AutomaticM = Manual Digit 21, 22, 23 — Electric Heat kW 000 = None010 = 1.0 kW (0.75 kW 208
  • Media type icon

    57229574B_06202023

    Document Title:Field Wiring Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-06-20
    /1 AVISO¡UTILICE ÚNICAMENTE CONDUCTORES DE COBRE!LAS TERMINALES DE LA UNIDAD NOESTÁN DISEÑADAS PARA ACEPTAROTROS TIPOS DE CONDUCTORES. NO REALIZAR LO ANTEDICHO PUEDEPROVOCAR DAÑOS EN EL EQUIPO. AVISN'UTILISER QUE DES CONDUCTEURS EN CUIVRE!LES BORNES DE L'UNITÉ NE SONTPAS CONÇUES POUR RECEVOIR
  • Media type icon

    ACC-SVN150G-EN_12032022

    Document Title:Accessory Electric Heat Foundation Packaged Rooftop Units 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2022-12-03
    or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. December 2022 ACC-SVN150G-EN Installation GuideAccessory Electric