Search Results: TEMP-PRC012A-EN

Showing 601 - 610 of 7,133 results

Display results per page.
  • Media type icon

    12132846B_12042024

    Document Title:SCHEMATIC - ELECTRIC HEAT WITH SCR MODULATING - 90KW - 480V
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-12-04
    CONTACTOR - HEAT CIRCUIT B 4393QA27 CONTACTOR - HEAT CIRCUIT C 4433QA27 CONTACTOR - HEAT CIRCUIT C 4703QA31 CONTACTOR - BACK-UP 4673QA31 CONTACTOR - BACK-UP 4363QA32 CONTACTOR - BACK-UP 4393QA32 CONTACTOR - BACK-UP 4693QA33 CONTACTOR - BACK-UP 4433QA33 CONTACTOR - BACK-UP 4703S10 HIGH TEMP LIMIT
  • Media type icon

    1213-4438E_12092022

    LEGENDREF DES DESCRIPTION LINE NOCFS SWITCH - CLOGGED FILTER 349ECA ACTUATOR - ECONOMIZER 321FOM MODULE - FRESH AIR OPTIONS 312OAH SENSOR - OUTDOOR AIR HUMIDITY 313RAH SENSOR - RETURN AIR HUMIDITY 309RASD SENSOR - RETURN AIR SMOKE DETECTOR 305RAT SENSOR - RETURN AIR TEMP 317RBA ACTUATOR
  • Media type icon

    VRF-PRC056A-EN_05082018

    Document Title:CITY MULTI CONTROLLER QUICK REFERENCE
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2018-05-08
    : Prohibited from Centralized Controllers depending on connected equipment.(start/stop, change mode, set temp, reset filter, change fan speed and change air direction). *6: Built-in motion and brightness sensor can be set to determine occupancy in the space. *7: Requires Wireless MA Receiver PAR-FA32MA
  • Media type icon

    18-HD45D1-7_04012016

    Document Title:Installation and User Guide Touchscreen Comfort Control TCONT624AS42DA
    Publication Type:Installation
    Publication Date:2016-04-01
    terminals)- None- Replaces internal sensor- Average with internal sensorOutdoor Temp Sensor (connect to the ODT terminals)- None- OutdoorCaution: Do not run sensor wires in the same bundle with HVAC wires. Keep away from high voltage wiring to avoid interference. Remote Tempurature Sensor Connections and
  • Media type icon

    1213-2978C_02282020

    REF DES DESCRIPTION LINE NOCC1 COMPRESSOR CONTACTOR 1 90CC1 (AUX2) CC1 AUX 2 NO 81CC2 COMPRESSOR CONTACTOR 2 92CC2 (AUX2) CC2 AUX 2 NO 82DTL1 DISCHARGE LINE TEMP LIMIT 1 102DTL2 DISCHARGE LINE TEMP LIMIT 2 98HPC1 HIGH PRESSURE CUTOUT 1 100HPC2 HIGH PRESSURE CUTOUT 2 96LPC1 LOW PRESSURE CUTOUT 1
  • Media type icon

    BAS-SVP044C-EN_10122025

    Document Title:Trane® Mitsubishi Electric VRF Integration License for the Tracer® SC+ System Controller
    Publication Type:Integration Guide
    Publication Date:2025-10-12
    . Improperly installed, adjusted or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. October 2025 BAS-SVP044C-EN Integration
  • Media type icon

    1213-2980B_12112019

    REF DES DESCRIPTION LINE NOAB ADAPTER BOARD 74 CC1 (AUX2) CC1 AUX 2 NO 81CC2 (AUX 2) CC2 AUX 2 NO 83 CC1 COMPRESSOR CONTACTOR 1 89CC2 COMPRESSOR CONTACTOR 2 92 CUS1 COMPRESSOR 1 UNLOADING SOLENOID 116CUS2 COMPRESSOR 2 UNLOADING SOLENOID 116DTL1 DISCHARGE LINE TEMP LIMIT 1 102DTL2 DISCHARGE LINE
  • Media type icon

    BAS-SVX074E-EN_06102023

    , bypassdamperControl spacetemperature setpoint No 1. Synchronize/temp setpointwith memberfunction 2. Bypass PressureSetpoint Yes Setup Wizard 38 BAS-SVX074E-EN Table 4. System type and corresponding additional settings (continued) System Type CharacteristicsInstallation Wizard Other VAV Settings
  • Media type icon

    RF-SLB013-EN_06162020

    Document Title:Trane® Creative Solutions - Waterside Economizers - Air-Cooled Chillers with Waterside Economizer, 20-500 Tons
    Publication Type:Sales Brochure
    Publication Date:2020-06-16
    real estate at the site. Plus, field piping and wiring is simplified; and maintenance is reduced. It is also architecturally pleasing with optional louvers! How A Waterside Economizer Works: When the ambient air temp is below the chilled water return temperature, the diverting valve opens and
  • Media type icon

    1213-2981C_02282020

    REF DES DESCRIPTION LINE NOAB ADAPTER BOARD 74CC1 COMPRESSOR CONTACTOR 1 90CC1 (AUX2) CC1 AUX 2 NO 81CC2 COMPRESSOR CONTACTOR 2 92CC2 (AUX2) CC2 AUX 2 NO 83CUS1 COMPRESSOR 1 UNLOADING SOLENOID 116CUS2 COMPRESSOR 2 UNLOADING SOLENOID 116DTL1 DISCHARGE LINE TEMP LIMIT 1 102DTL2 DISCHARGE LINE TEMP