Search Results: TEMP-SLB008-EN

Showing 581 - 590 of 7,117 results

Display results per page.
  • Media type icon

    12134630C_12042024

    Document Title:CONTROLS SCHEMATIC, 20T-75T - RETURN SECTION #1
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-12-04
    PTC Plotter Output LEGENDREF DES DESCRIPTION LINE NO5BT8 SENSOR - MIXED AIR TEMPERATURE 3065BT11 SENSOR - ENTERING EVAP AIR TEMP COIL #1 3075BT12 SENSOR - ENTERING EVAP AIR TEMP COIL #2 3056BM1 SENSOR - OUTDOOR AIR HUMIDITY 3426BM2 SENSOR - RETURN AIR HUMIDITY 3406BT1 SENSOR - OUTDOOR AIR TEMP
  • Media type icon

    BAS-SVP044C-EN_10122025

    Document Title:Trane® Mitsubishi Electric VRF Integration License for the Tracer® SC+ System Controller
    Publication Type:Integration Guide
    Publication Date:2025-10-12
    . Improperly installed, adjusted or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. October 2025 BAS-SVP044C-EN Integration
  • Media type icon

    CVHE-CLD-1A_02012000

    Document Title:Refrigeration. Water-Cooled, Hermetic CenTraVac, Clear Language Display for UCP2 Control Panels. Models CVHE, CVHF and CVHG 50 and 60 Hz See CVRB-SUPL-1 5/1/96 for more information.
    Publication Type:Installation Operation and Maintenance
    Publication Date:2000-02-01
    ...................................................... 10 Chiller Operating Mode ..................................... 10Chiller Operating Mode ..................................... 12Active Chilled Water Setpoint/Evap LeavingWater Temp ..................................................... 12 Active Chilled Water Setpoint/Chilled
  • Media type icon

    1213-5031B_10162024

    VAC-P OUT CONTROL 2 PROVING INCOMPRESSOR 2 24 VAC IN COMPRESSOR 2 RUNCOMPRESSOR 2 UNLOADER/CCH NOT USED24 VAC-P OUT CIRCUIT 3 PROVING INCOMPRESSOR 3 24 VAC IN COMPRESSOR 3 RUNCOMPRESSOR 3 UNLOADER/CCH SOV1 OUT (24 VAC-S)GND-S SOV2 OUT (24 VAC-S)GND-S COMMONECM CONDENSER FAN CONTROL DISCHARGE AIR TEMP
  • Media type icon

    1213-4853B_09112024

    CONDENSER FAN CONTROL DISCHARGE AIR TEMP OUTDOOR AIRTEMP COIL TEMP 1 COIL TEMP 2 COIL TEMP 3 CIRCUIT 1 DISABLE CIRCUIT 2 DISABLE FROSTAT IN DEMAND LIMIT/SHED24 VAC-P OUT 24 VDC OUT COMMON SPACE HUMIDITY COMMON CO2 IN (0- 10 VDC) 24 VDC OUT 24 VAC OUT LOCAL O CCUPANCY 24 VAC OUT EMERGENCY STOP BACNET
  • Media type icon

    1213-5030B_10162024

    INCOMPRESSOR 2 24 VAC IN COMPRESSOR 2 RUNCOMPRESSOR 2 UNLOADER/CCH NOT USED24 VAC-P OUT CIRCUIT 3 PROVING INCOMPRESSOR 3 24 VAC IN COMPRESSOR 3 RUNCOMPRESSOR 3 UNLOADER/CCH SOV1 OUT (24 VAC-S)GND-S SOV2 OUT (24 VAC-S)GND-S COMMONECM CONDENSER FAN CONTROL DISCHARGE AIR TEMP OUTDOOR AIRTEMP COIL TEMP 1
  • Media type icon

    1213-2649E_09302019

    Document Title:INTELLIPAK - CONTROLS SCHEMATIC, 20T-75T - RETURN SECTION #2
    Publication Type:Wiring Diagram or Manual
    Publication Date:2019-09-30
    SENSOR - SUPPLY AIR TEMP 372 4QA19 CONTACTOR - SUPPLY VFD BYPASS #1 409,4104QA20 CONTACTOR - SUPPLY VFD BYPASS #2 412,4134QA21 CONTACTOR - SUPPLY VFD RUN #1 409,4104QA22 CONTACTOR - SUPPLY VFD RUN #2 412,4135BT13 SENSOR - LEAVING EVAP AIR TEMP COIL #2 3635BT4 SENSOR - CKT #1 EVAP SUCTION TEMP #1
  • Media type icon

    1213-4269A_11032021

    REF DES DESCRIPTION LINE NOAB ADAPTER BOARD 27 CC1 COMPRESSOR CONTACTOR 1 29CC1 (AUX2) CC1 AUX2 NO 20 CC2 COMPRESSOR CONTACTOR 2 31CC2 (AUX2) CC2 AUX2 NO 21 DTL1 DISCHARGE LINE TEMP LIMIT 1 41DTL2 DISCHARGE LINE TEMP LIMIT 2 37HPC1 HIGH PRESSURE CUTOUT 1 39HPC2 HIGH PRESSURE CUTOUT 2 35LCI LONTALK
  • Media type icon

    12134767_A_08112023

    REF DES DESCRIPTION LINE NOAB ADAPTER BOARD 27 CC1 COMPRESSOR CONTACTOR 1 29CC1 (AUX2) CC1 AUX2 NO 20 CC2 COMPRESSOR CONTACTOR 2 31CC2 (AUX2) CC2 AUX2 NO 21 DTL1 DISCHARGE LINE TEMP LIMIT 1 41DTL2 DISCHARGE LINE TEMP LIMIT 2 37HPC1 HIGH PRESSURE CUTOUT 1 39HPC2 HIGH PRESSURE CUTOUT 2 35LCI LONTALK
  • Media type icon

    AHU-SLB002-EN_04302020

    Document Title:Low Temp AHU / Rental Services
    Publication Type:Sales Brochure
    Publication Date:2020-04-30
    Low Temp AHU WatersideOur low-temp air handling units are specifically designed for cooler, freezer type applications where there is a requirement for air temperatures below 32°F. Multiple AHU ApplicationsIn order to prevent a decrease in airflow supply due to excessive frozen coils, the unit