    Document Title:Control Schematic (Wiring Diagram) for units with Dual compressor and Single Fan
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-08-09
    REF DES DESCRIPTION LINE NOAB ADAPTER BOARD 27 CC1 COMPRESSOR CONTACTOR 1 29CC1 (AUX2) CC1 AUX2 NO 20 CC2 COMPRESSOR CONTACTOR 2 31CC2 (AUX2) CC2 AUX2 NO 21 CTS1 COIL TEMP SENSOR 1 27CTS2 COIL TEMP SENSOR 2 29DTL1 DISCHARGE LINE TEMP LIMIT 1 41DTL2 DISCHARGE LINE TEMP LIMIT 2 37HPC1 HIGH PRESSURE
  • Media type icon

    1213-4349B_02022022

    Document Title:Precedent™ SCHEMATIC; SHEET 3, CONTROLS, SYMBIO 700 UNIT CONTROLS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-02-02
    24 VAC INCONTROL 24 VAC OUTCIRCUIT 3 PROVING IN COMPRESSOR 3 24 VAC INCOMPRESSOR 3 RUN COMPRESSOR 3 UNLOADER/CCH SOV1 OUTCOMMON SOV2 OUTCOMMON COMMONECM CONDENSER FAN CONTROL DISCHARGE AIR TEMP OUTDOOR AIRTEMP COIL TEMP 1 COIL TEMP 2 COIL TEMP 3 CIRCUIT 1 DISABLE CIRCUIT 2 DISABLE CIRCUIT 3 DISABLE
  • Media type icon

    GTNE-SVN002C-EN_08212020

    Document Title:Four-Inch Combustion Air Inlet Kit Tubular Gas-Fired Direct Spark Propeller Unit Heaters Category III Venting for Separated Combustion for 30,000 to 75,000 Btu/h
    Publication Type:Installation
    Publication Date:2020-08-21
    GTNE-SVN002B-EN (06 Jul 2015): Installation Instructions - Four-Inch Combustion Air Inlet Kit - Tubular Gas-Fired Direct Spark Propeller Unit Heaters - Unit Conversion and Category III Venting for Separated Combustion for 20,000 to 75,000 Btu/h Four-Inch Combustion Air Inlet KitTubular Gas-Fired
  • Media type icon

    2313-0817B_08272010

    Document Title:Rooftop Packaged Air Conditioner Diagram, Field Connections - Constant Volume, 90T-162T Units and Air Handlers
    Publication Type:Wiring Diagram or Manual
    Publication Date:2010-08-27
    NC598 599 597 HUMIDIFICATION 9K27VENTILATION OVERRIDE MODE B CONTACTS HEAT 7 COOL 8 SYS ON 9 SERVICE 10 GND 11 508 512 511 510 509 COMM (+) 12 513 9U44REMOTE PANELWITH NSB S1 S2 50224 VAC 14 9U40REMOTE ZONE TEMPSENSOR 9U39ZONE TEMPSENSOR 504 503 5 HEAT SETPOINT 3 COOL SETPOINT 1 ZONE TEMP 2 COMMON
  • Media type icon

    12134688_B_02202023

    Document Title:COMPONENT LAYOUT; 265-300KW ELECTRIC HEAT
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-20
    SWITCH- TEMP (MANUAL RESET) 10443S11 SWITCH- TEMP(AUTO RESET #1) 10283S12 SWITCH- TEMP(AUTO RESET #2) 1040 3XD16 TERMINAL BLOCK - 115VAC 10353XD17 TERMINAL BLOCK-115VAC COMMON 10333XD27 TERMINAL BLOCK 1042 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039
  • Media type icon

    WSHP-SVX023C-EN_01122026

    . Improperly installed, adjusted or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. January 2026 WSHP-SVX023C-EN
  • Media type icon

    RSP-SLB165-EN_08012009

    Document Title:Trane - Honeywell - Thermostat Full Line - The Thermostat Leader -One Brand for Every Application, Budget, and Customer.
    Publication Type:Sales Brochure
    Publication Date:2009-08-01
    INFORMATION COMPETITIvE CROSS REFERENCE Mn emo nic Nu mb er HO NE YW EL L OS Nu mb er Pro gra m O pti on s EN ER gY STA R® Tem po rary Ove rrid e Ho liday Co nven tio nal Hea t P um p Mo du lati ng Fan Co il PTA C Rea l-T ime Clo ck (Au tom atic ally Up dat es Day ligh t S avin gs) Per man ent Mem ory
  • Media type icon

    12134910_B_08012024

    Document Title:SCHEMATIC, SHEET 6, CONTROLS, FRESH AIR OPTIONS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-08-01
    LEGENDREF DES DESCRIPTION LINE NO ECA ACTUATOR - ECONOMIZER 321FAOM MODULE - FRESH AIR OPTIONS 312OAH SENSOR - OUTDOOR AIR HUMIDITY 313RAH SENSOR - RETURN AIR HUMIDITY 309RAT SENSOR - RETURN AIR TEMP 317XFR CONTACTOR - POWER EXHAUST 316 CONDUCTOR NAME CONDUCTOR BASE COLOR CONDUCTOR TRACER COLOR1
  • Media type icon

    B151963P04_06012009

    Document Title:DEMAND DEFROST CONTROL CHECKOUT "E" Model Heat Pumps
    Publication Type:Installation
    Publication Date:2009-06-01
    conditions for defrost met? (OD Temp. below 49F, OD Coil Temp. below 35F, deltaT increasing) IMPORTANT --- This document is customer property and is to remain with this unit. Please return to service information pack upon completion of work. NO: A10 CHECKS (see Check List) ACTIONS (see Action List) THIS
  • Media type icon

    12132844B_12042024

    Document Title:SCHEMATIC - ELECTRIC HEAT WITH SCR MODULATING - 30KW - 208V/240V
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-12-04
    -UP 4353QA31 CONTACTOR - BACK-UP 4673QA32 CONTACTOR - BACK-UP 4693QA32 CONTACTOR - BACK-UP 4383S10 HIGH TEMP LIMIT - MANUAL RESET 4663S11 HIGH TEMP LIMIT - AUTO RESET #1 4653S12 HIGH TEMP LIMIT - AUTO RESET #2 4653S13 HIGH TEMP LIMIT - AUTO RESET #3 4653XD5 TERMINAL BLOCK 4283XD16 TERM BLOCK - 115 VAC