Search Results: VAV-SLB018-EN

Showing 51 - 60 of 7,117 results

Display results per page.
  • Media type icon

    APP-PRC009A-EN_06122023

    airflow requirement of the zone, and avoid sizes where the maximum (design) airflow is less than half of the factory-designed nominal flow (see page 32). Consult the “Selection Procedure” detailed in either the VariTrane® Round Inlet/Round Outlet product catalog (VAV-PRC016*-EN) or the VariTrane®
  • Media type icon

    PKG-SVX029C-EN_08012025

    Document Title:Commercial Self-Contained Units SWUD - R-454B - 20 to 110 Tons
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-08-01
    in the duct and toincrease fan performance. To complete trunk ductwork tothe VAV terminal units, refer to the VAV box manuals for Installation – Mechanical PKG-SVX029C-EN 27 specific requirements. Check total external static pressuresagainst fan characteristics to be sure the required airflow
  • Media type icon

    OAU-SVX004G-EN_06262023

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93 Space Control or Single Zone VAV and OA Set-points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93 Discharge Air Temp. Reset for Single Zone VAV 94 Supply Fan Tracking for Exhaust Fan (Field En-abled
  • Media type icon

    BAS-SVP053A-EN_04162022

    Document Title:BACnet® Communication Interface for ReliaTel™ Controllers (BCI2-R)
    Publication Type:Integration Guide
    Publication Date:2022-04-16
    BBAASS--SSVVPP005533AA--EENN Integration Guide BACnet®® Communication Interfacefor ReliaTel™™ Controllers (BCI2-R) ©2022 Trane BAS-SVP053A-EN IntroductionThe BACnet Communication Interface for ReliaTel (BCI2-R) supportsTrane ReliaTel rooftop unitsthat function as part of a BACnet MS/TP communications
  • Media type icon

    OAU-SVX02J-EN_06232023

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Discharge Air Temp. Reset for Single Zone VAV 73 Supply Fan Tracking for Exhaust Fan (Field En-abled) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Hot Water Reheat . . . . . . . . . . . . . . . . . . . 73 Expanded Fallback Control
  • Media type icon

    BAS-SVN095D-EN_06112020

    of the following equipment:• Tracer® UC400 programmable controller.• BACnet® Communication Interface for Chillers (BCI-C).• BACnet Communication Interface for IntelliPak (BCI-I). Required Tools • Tracer TU• USB Cable X39641210-01 June 2020 BAS-SVN095D-EN Installation Instructions Service Part For
  • Media type icon

    APP-PRC005J-EN_07152022

    Document Title:System Catalog - Zoned Rooftop Systems
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2022-07-15
    nominal flow (see page 39). Consult the “Selection Procedure” detailed in either the VariTrane® Round Inlet/Round Outlet product catalog (VAV-PRC016*-EN) or the VariTrane® Single-Duct Units product catalog (VAV-PRC011*-EN). Bypass damper. Avoid oversizing the bypass damper. Oversizing often results in
  • Media type icon

    OAU-SVX01L-EN_06262023

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Discharge Air Temp. Reset for Single Zone VAV 85 Supply Fan Tracking for Exhaust Fan (Field En-abled) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Hot Water Reheat . . . . . . . . . . . . . . . . . . . 85 Expanded Fallback
  • Media type icon

    RT-SVX22V-EN_04022020

    Document Title:Packaged Rooftop Air Conditioners Precedent™ — Electric/Electric 3 to 10 Tons – 60 Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-04-02
    . Discharge Air Sensing is also standard equipment on units with Single Zone and Supply Air Temperature Control VAV. 21. RT-SVX22V-EN 11 General Information Unit Inspection As soon as the unit arrives at the job site • Verify that the nameplate data matches the data on the sales order and bill of
  • Media type icon

    BAS-SVN045K-EN_12012022

    Document Title:Rover™ Service Tool
    Publication Type:Installation
    Publication Date:2022-12-01
    (or VAV) Black Red UR11 jack on protection module Alligator clips(Clip to communicationsterminals on the device) RJ11 plug Adapter cable Comm4PCMCIA card Figure 14. Checking USB or PCMCIA port CCoonnnneeccttiinngg ttoo aa CCoommmm44 LLiinnkk 16 BAS-SVN045K-EN Connecting to a Comm4 Link Using the