    18-AH68D1-1E-EN_07152020

    Document Title:Installer's Guide Horizontal Conversion Kit for 4PXC*U and 4PXC*D Conversions
    Publication Type:Installation
    Publication Date:2020-07-27
    removing sealing plugs. If no pressure is released, check for leaks. 18-AH68D1-1E-EN 2 18-AH68D1-1E-EN Installer’s Guide CAUTION!Caution: This coil is pressurized with 8-12 psig of dry air. Do not stand directly in front of the coil connections when removing sealing plugs. If no pressure is released
  • Media type icon

    SSA-PRC006-EN_12012014

    Document Title:Illusion Concealed Type Minisplit Air Conditioners 12,000 - 60,000 Btu/h MCD Series 50 / 60 Hz / Product Bulletin
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2014-12-01
    1.25 / 1.53 cfm (cmh) 1490 (2532) 1600 (2717) 1600 (2717) 1600 (2717) No. of Blade 4 4 4 4 Fins per inc 14 18 18 18 SSA-PRC006-EN 17 General Data General Data TTK 60 Hz POWER CONNECTION V/ph/Hz 200-240/1/60 200-240/1/60 200-240/1/60 200-240/1/60MCA1, 3 SYSTEM DATARefrigerant Type R-22 R-22 R-22 R
  • Media type icon

    ACC-SVN57N-EN_04232020

    Document Title:Power Exhaust Kit - Standard and Low Leak Economizers 6 to 10 Tons
    Publication Type:Installation
    Publication Date:2020-04-23
    allowable waiting periods for discharge of capacitors. Verify with an appropriate voltmeter that all capacitors have discharged. For additional information regarding the safe discharge of capacitors, see PROD-SVB06*-EN. 1. Remove 6P7 plug from actuator module. 2. Using 18 ga. red quick splice connectors
  • Media type icon

    BAS-SVN028L-EN_08062022

    Document Title:Trane® Commercial Touch Screen Programmable Zone Sensor for ReliaTel™, UC400 and Symbio™ 400/700/800 Controls
    Publication Type:Installation
    Publication Date:2022-08-06
    to BACnet. Important: Install a jumper wire between terminals J6-1 and 2 when the internal temperature sensor or a sensor wired to terminals 17 and 18 is used. . 8 BAS-SVN028L-EN Zone Sensor Wiring Symbio™ 400/UC400The zone sensor and the Symbio™ 400/UC400 form a two-node BACnet MS/TP network
  • Media type icon

    18-GJ79D1-1F-EN_08032020

    Document Title:Installer's Guide Slim Fit Filter Box Kit for TEM/A4AH4/TVM Series A Cabinet Air Handlers
    Publication Type:Installation
    Publication Date:2020-08-11
    - TEM6A0D48,60 INSTALLER'SGUIDE IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES 18-GJ79D1-1F-EN Section 1. Safety Information ss
  • Media type icon

    AH-PRC010A-EN_01082020

    (Pressure Drop, ftH2O) 29 (12) 32 (10) 39 (9) 40 (12) 50 (11) 70 (20) 80 (14) 103 (18) Table 5. Performance/Capacity data — TR-CFD/TR-CFF 45oF EWT/0% glycol (continued) Model TR-CFD/TR-CFF- 060-C1 090-C1 120-C1 150-C1 180-C1 190-C1 230-C1 280-C1 14 AH-PRC010A-EN Performance Data Table 6. Performance
  • Media type icon

    ODR-SVX009A-EN_07232025

    -BC119D1- 1C-EN.• Updated Unit dimensions and weight table in Unit Location Considerations chapter.• Updated procedural step in Calculating charge using the weigh-In method topic in System ChargeAdjustment chapter. Introduction ODR-SVX009A-EN 5 Pre-Installation
  • Media type icon

    UH-PRC002P-EN_07012022

    in excess of 2,000 ft. (610m) are to be ignored. At altitudes of 2,000 ft to 4,500 ft (610 m to 1372 m), the unit must be field derated, and be so marked in accordance with the ETL certification. (a) ODP = Open Drip Proof; SP = Shaded Pole; PSC = Permanent Split Capacitor 18 UH-PRC002P-EN Performance
  • Media type icon

    18-CD19D7-29-EN_09012016

    Document Title:Installer's Guide - Upflow/Horizontal Downflow/Horizontal, Gas-Fired Furnaces, Fan Assisted Combustion System Models: AUD1, TUD1, ADD1, TDD1
    Publication Type:Installation
    Publication Date:2016-09-01
    18-CD19D7-29-EN Upflow / Horizontal — Downflow / Horizontal, Gas-Fired Furnaces, “Fan Assisted Combustion System” Installer’s Guide Upflow / Horizontal* Downflow / Horizontal* For VENT SIZING INFORMATION see:USA —National Fuel Gas Code ........ ANSI Z223.1/NFPA 54 (latest version) CANADA — Natural
  • Media type icon

    18-CD33D1-11-EN_02012019

    Document Title:Installer's Guide High Efficiency Single Stage Upflow/Horizontal and Downflow/Horizontal Gas-Fired, Direct Vent Condensing Furnaces *UH1-H, *DH1-H (* first letter may be A or T)
    Publication Type:Installation
    Publication Date:2019-02-01
    /HORIZONTAL 18-CD33D1-11-EN © 2019 Trane All Rights Reserved 18-CD33D1-11-EN Installer’s GuideSAFETY SECTION The following safety practices and precautions must be followed during the installation, servicing, and operation of this furnace. 1. Use only with the type of gas approved for this furnace. Refer to