    RT-PRC125A-EN_09152024

    -PRC125A-EN 27 Table 10. Gross cooling capacities 25 tons — E/GDK300A3,4,W CFM EntDB (°F) Ambient Temperature (°F) Ambient Temperature (°F) Ambient Temperature (°F) 85 95 105Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) 61 67 73 61 67 73 61 67 73MBh SHC MBh SHC
  • Media type icon

    SSP-PRC023V-EN_01122025

    Data SSP-PRC023V-EN 35 Table 19. Gross cooling capacities (MBH) 6 tons TWA0724*A condensing unit only (IP) Outdoor Temp(°F) Saturation Suction Temperature (°F) 30 35 40 45 50 55 65 Head Press (psig) 265.1 271.6 278.5 285.6 293.0 300.7Capacity (Btuh/1000) 68.9 75.5 82.6 90.1 98.2 106.9Unit Power (kW
  • Media type icon

    ACC-SVN303A-EN_09152024

    Document Title:0 to 100% Downflow Dry Bulb Economizer Foundation™ Packaged Cooling and Gas/Electric 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    Sensor Differential Dry Bulb OA Temp < RA Temp - Economizer Dry Bulb Enable Offset - Economizer Dry Bulb Disable Return Air Offset Outdoor Air Temperature Sensor Return Air Temperature Sensor Figure 24. Fresh air options module location Fresh Air Module Access 12 ACC-SVN303A-EN Notes ACC-SVN303A-EN
  • Media type icon

    AC-SVX004D-EN_05162025

    828 Water connection in. 4 4 4 4 4 4 4 4 4 General Information AC-SVX004D-EN 13 Table 3. General data – ACX (I-P) (continued) Max initial water temp at start-up(cooling) °F 105 105 105 105 105 105 105 105 105 Max chilled water setpoint (cooling) °F 68 68 68 68 68 68 68 68 68Max hot water setpoint
  • Media type icon

    18-HD88D1-1D-EN_03182021

    Document Title:ComfortLink II XL1040 TZON1040 Zone Sensor Installation and User Guide TZON1040AC52ZA
    Publication Type:Installation
    Publication Date:2021-03-18
    ComfortLink™ II XL 1040TZON1040 Zone Sensor Installation & User Guide The 1040 is an easy to use communicating zone sensor with a color touch screen. This guide will help you install and configure your TZON1040 zone sensor quickly and easily. 18-HD88D1-1D-EN page 1 TZON1040 Installation and User
  • Media type icon

    18-GJ37D1-6A-EN_08042020

    Document Title:Installer's Guide Top Mount Hydronic Coil Accessory Fits Hyperion and ForeFront Air Handler Models BAYWACC11SC1AA
    Publication Type:Installation
    Publication Date:2020-08-11
    NATIONAL, STATE AND LOCAL CODES 18-GJ37D1-6A-EN Model:BAYWACC11SC1AA Table of ContentsSection 1. Safety Considerations.........................2Section 2. General Information ............................3Section 3. Hydronic Coil Assembly .....................4Section 4. Install Hydronic Coil
  • Media type icon

    ODR-SVX002C-EN_04172026

    Document Title:Condensing Units
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-04-17
    or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. April 2026 ODR-SVX002C-EN Condensing
  • Media type icon

    ODR-SVX028A-EN_03202026

    altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. March 2026 ODR-SVX028A-EN Condensing
  • Media type icon

    RT-PRC060N-EN_12032022

    airflow table notes.2. MBh = Total gross capacity3. SHC = Sensible heat capacity Performance Data RT-PRC060N-EN 21 Table 5. Gross cooling capacities 20 tons - E/GCC240A3,4,W CFM EntDB (°F) Ambient Temperature (°F) Ambient Temperature (°F) Ambient Temperature (°F) 85 95 105Entering Wet Bulb Temp (°F
  • Media type icon

    BAS-SVP066B-EN_04132024

    Document Title:BACnet® and Modbus™ Integration to Voyager™ 3 Packaged Rooftop Air-Conditioners with Symbio™ 700 Controls
    Publication Type:Integration Guide
    Publication Date:2024-04-13
    will use the Space Temp Cooling Setpoint Status.7. If the Heat Cool Mode Status is Heat then the Symbio™ 700 controller will use the Space Temp Heating Setpoint Status. Appendix A: Arbitrations 82 BAS-SVP066B-EN Space Temperature Setpoint Dual Setpoint Method The Space Temperature Dual Setpoint