Search Results: TEMP-SLB008-EN

Showing 181 - 190 of 7,117 results

Display results per page.
  • Media type icon

    RLC-SVX09T-EN_10312025

    Condenser Leaving Hot Water TempControl1 = Condenser Leaving Hot Water Temp Control RLC-SVX09T-EN 9 Digit 36 — Power Meter 0 = No Power MeterE = Energy Meter Digit 37 — Motor Current Analog Output (%RLA)0 = No Motor Current Analog Output1 = Motor Current Analog Output Digit 38 — A/C Fan Control 0 = No
  • Media type icon

    ODR-SVX015A-EN_09192025

    Document Title:Condensing Units
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-09-19
    or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. September 2025 ODR-SVX015A-EN Condensing
  • Media type icon

    RT-PRC128A-EN_01122025

    sea level. General Data 18 RT-PRC128A-EN Performance DataGross Cooling CapacitiesTable 5. Gross cooling capacities 7.5 tons CFMEntDB (°F) Ambient Temperature (°F) Ambient Temperature (°F) Ambient Temperature (°F) 85 95 105Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp
  • Media type icon

    RT-SVX064C-EN_04302024

    – Enabled N Circuit 2 Reversing Valve(a) Disabled – Enabled N Condenser Fan Command(a) Disabled – Enabled N OA/RA Damper Position Command 0% – 100% N 34 RT-SVX064C-EN System Configuration and Pre-Start Reports (continued from previous page) System Setpoints DAT High Temp Cutout 100°F 125°F 150°F Y
  • Media type icon

    SO-SVU001A-EN_10132023

    AFD Surge Capacity Increase 1 Tracer TU Status View: Motor Average Line Current Starter Average Phase Voltage Starter Load Power Factor Motor Winding #1 temp Motor Winding #2 temp Motor Winding #3 temp SO-SVU001A-EN 51 Start-Up Test Log Water-Cooled CenTraVac Chiller with CH530/CH531 Control and
  • Media type icon

    AC-SLB005-EN_09262025

    Document Title:Ascend™ Air-to-Water Heat Pump - Efficient. Sustainable. Reliable. The all-electric solution for modern commercial buildings.
    Publication Type:Sales Brochure
    Publication Date:2025-09-26
    dependable solution for extreme weather conditions. Capacity Range 80-230T1000-2500 MBH heating Operating Map Cooling: 20°F to 68°F, -4°F to 125°F ambientHeating: 55°F to 145°F (80-120T)Heating: 68°F to 140°F (140-230T)Max leaving temp at minimum ambient (80-120T) (requires waterside reversing valve):145°F
  • Media type icon

    18-BC102D1-1B-EN_07082020

    Document Title:Installer's Guide Variable Speed Side Discharge HP AOC Replacement KIT18534
    Publication Type:Installation
    Publication Date:2020-07-15
    purposes, the matter should be referred to your local distributor. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES Installer’s GuideVariable Speed Side Discharge HP AOC Replacement KIT18534 18-BC102D1-1B-EN Table of ContentsSection 1. Safety
  • Media type icon

    1213-2219C_08312016

    Document Title:Foundation Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2016-08-31
    101 1 2 3 LTB2 101AF(BL),101AG(BL) 101AU(W) 8 4 1 5 2 3 6 4 EER1 101AU(W)162A(BK) 164A(BK) 163A(BK) LEGEND DEVICE DESIGNATION DESCRIPTION CCH CRANKCASE HEATER CO2 CO2 SENSOR COF CONDENSATE OVERFLOW SWITCH CPR COMPRESSOR DISC SINGLE POINT DISCONNECT DTL SWITCH - DISCHARGE TEMP LIMIT ECA ECONOMIZER
  • Media type icon

    1213-2218C_08312016

    Document Title:Foundation Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2016-08-31
    101 1 2 3 LTB2 101AF(BL),101AG(BL) 101AU(W) 8 4 1 5 2 3 6 4 EER1 101AU(W)162A(BK) 164A(BK) 163A(BK) LEGEND DEVICE DESIGNATION DESCRIPTION CCH CRANKCASE HEATER CO2 CO2 SENSOR COF CONDENSATE OVERFLOW SWITCH CPR COMPRESSOR DISC SINGLE POINT DISCONNECT DTL SWITCH - DISCHARGE TEMP LIMIT ECA ECONOMIZER
  • Media type icon

    1213-2268B_08312016

    Document Title:Foundation Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2016-08-31
    101 1 2 3 LTB2 101AF(BL),101AG(BL) 101AU(W) 8 4 1 5 2 3 6 4 EER1 101AU(W)162A(BK) 164A(BK) 163A(BK) LEGEND DEVICE DESIGNATION DESCRIPTION CCH CRANKCASE HEATER CO2 CO2 SENSOR COF CONDENSATE OVERFLOW SWITCH CPR COMPRESSOR DISC SINGLE POINT DISCONNECT DTL SWITCH - DISCHARGE TEMP LIMIT ECA ECONOMIZER