Search Results: 2022

Showing 181 - 190 of 974 results

Display results per page.
  • Media type icon

    OAU-WPR001A-EN_08142025

    with air-cooled condensers and packaged DX DOAS units condition A condition B condition C condition D IEER rating conditions (AHRI 340/360-2022) IEER = (0.020 x A) + (0.617 × B) + (0.238 × C) + (0.125 × D) evaporator entering-air conditions 80°F DBT 80°F DBT 80°F DBT 80°F DBT condenser entering-air
  • Media type icon

    12134529_B_12122022

    Document Title:CONTROLS - ADAPTER BOARD UNIT CONTROLS |THREE COMPRESSORS (eSTAGE), 3/4 FANS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-12-12
    M.DERNOVSEKB.JONES 3-15-2022- - 5-9-2022M.DERNOVSEK -CREO SCHEMATICS - 12134529 B4 VOYAGER 3TRANE ® CC1 (AUX2) CC2 (AUX2) CC3 (AUX2) CC1 CC2 CC3 HPC1 HPC2 HPC3 VHR-NC 65 VHR-NO 42 VHR VHR-TBL3L2L1 T3T2T1 OFC1 OFC2 OFC3 24 VAC-A OUTGND-AIMC+IMC- 24 VAC-A OUTGND-AIMC+IMC- 24 VAC-A OUTGND-AIMC+IMC- 24
  • Media type icon

    12134354_B_07192022

    Document Title:IPAK1 POWER SCHEMATIC 20-75T AIRFLOW, WITHOUT BYPASS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-07-19
    COPIED ORITS CONTENTS DISCLOSED TO OUTSIDE PARTIES WITHOUT THEWRITTEN CONSENT OF TRANE. DESIGNER:ENGINEER:TRANE © DATE:REPLACES: SIMILAR TO: REVISION DATE:REVISED BY:APPROVED BY:CAD SYSTEM USED: MASTER NUMBER: DRAWING NUMBER: SHEET: REV R JOHNSONS MCKINLEY 28 MAR 2022 28 MAR 2022R JOHNSON S
  • Media type icon

    23115999_B_05122023

    Document Title:Schematic - Wye-Delta Starter
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-05-12
    CONTENTS DISCLOSEDTO OUTSIDE PARTIES WITHOUT THE WRITTEN CONSENT OF TRANE REV SHEET DRAWN BY: TRANE DATE: MASTER FILE: REVISION DATE: REPLACES: SIMILAR TO: USED BY: CR 2311-5999 B SCHEMATICRTWD70-250 TON WYE DELTA STARTER WEIYING MIAO 07-MAY-2022 ! WARNINGHAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC
  • Media type icon

    12134601_A_06292022

    Document Title:Wiring Diagram / Foundation - DEVICE LOCATION - WITH VFD - 15T-25T - 60 HZ
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-06-29
    OPTIONAL FIELD INSTALLED ON 25T OPTIONAL LSD STANDARD ON 15T, 17.5T, 20T AND OPTIONAL FIELD INSTALLED ON 25T OPTIONAL FIELD INSTALLED LOW AMBIENT CONTROLLER LOAM RELEASED 27/Sep/2022 04:46:16 GMT Sheet 1
  • Media type icon

    12134660_B_02202023

    Document Title:IPAK 2 POWER SCHEMATIC 90-150T SERVICE LIGHTS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-20
    . DESIGNER:ENGINEER:TRANE © DATE:REPLACES: SIMILAR TO: REVISION DATE:REVISED BY:APPROVED BY:CAD SYSTEM USED: MASTER NUMBER: DRAWING NUMBER: SHEET: REV R. JOHNSONS. ESPARZA 10 NOV 2022 10 NOV 2022R. JOHNSON S. ESPARZACREO SCHEMATICS 12134660 BOF3 17 IPAK 2POWER SCHEMATIC90-150T SERVICE LIGHTS TRANE ® T1 1S27 L1
  • Media type icon

    12134517_B_12122022

    Document Title:POWER - THREE COMPRESSORS (eSTAGE), 3/4 CONDENSER FANS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-12-12
    -MAR-2022- - 26-APR-2022S.VAVHAL B.JONESCREO SCHEMATICS - 12134517 B1 VOYAGER3UNIT SCHEMATIC; SHEET 1 POWER THREE COMPRESSOR3/4 CONDENSER FAN TRANE ® 2A(O) 2A 3A(Y) 3A 141C(O/W) 142C(O/W)143A(O/W)144A(O/W) PPF13512 143D(O/W)144D(O/W) PPM13512 XFMR1FDS CCH1 FU21 FU22 FU23 CCH2 FU24 FU25 FU26 CCH3 FU46
  • Media type icon

    PART-SVN255A-EN_12032022

    Document Title:Agility™ Water-cooled Chiller Filterless Motor Compressor Retrofit
    Publication Type:Installation
    Publication Date:2022-12-03
    Agility™ Water-cooled Chiller Filterless Motor Compressor RetrofitKIT19897 Installation Instructions December 2022 SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment
  • Media type icon

    SYS-SLB032-EN_01242025

    Document Title:Electrify to Decarbonize - Air-to-Water Heat Pump System with Hydronic Branch Conductor
    Publication Type:Sales Brochure
    Publication Date:2025-01-24
    , Department of Energy, 20152. Center for Climate and Energy Solutions, referenced 1/22/20253. Encentiv Energy, 20244. How Many Companies Have Sustainability Reports – ictsd.org, 2022 Public Policy & Legislation is Driving Decarbonization 24+States have decarbonization targets2 Increased Utility Incentives for
  • Media type icon

    BAS-SVN230A-EN_030502022

    Document Title:Tracer® Symbio UC210 Bypass Damper Controller / Installation Instructions
    Publication Type:Installation
    Publication Date:2022-03-05
    , adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. ©2022 Trane Packaged Contents • One (1) Symbio 210 Bypass