Search Results: 18-CH83D1-1B-EN

Showing 171 - 180 of 7,117 results

Display results per page.
  • Media type icon

    2313-0324A_07132010

    Document Title:Connection Electrical Cooling/Gas Heat 400-575V YC 211E, 240E, 241E
    Publication Type:Wiring Diagram or Manual
    Publication Date:2010-07-13
    WHEN RTOM OR ECA IS INSTALLED W/O COMM BOARD 97A(PR) 15A(BK) HI/SINGLE LO CBM L1 83A(BR) ,E A(PR) A,B(RD) B(RD) W8(PR) E(BL) B(PR) -- -- 18 19 21 21XE F MAT OAH/OAE OAT RAT RAH/RAE DCV 21 21 21 21 21 21 21 21 21 21 21 21 54321SW1ON COMM TB2TB1 PPF5 1 2 4 5 J2 10B(RD) 1C(RD)BLACK BLACKCCH1 GREEN
  • Media type icon

    2313-0326A_07132010

    Document Title:Connection Electrical Cooling/Gas Heat 400-575V YC 150
    Publication Type:Wiring Diagram or Manual
    Publication Date:2010-07-13
    WHEN RTOM OR ECA IS INSTALLED W/O COMM BOARD 97A(PR) 15A(BK) HI/SINGLE LO CBM L1 83A(BR) ,E A(PR) A,B(RD) B(RD) W8(PR) E(BL) B(PR) -- -- 18 19 21 21XE F MAT OAH/OAE OAT RAT RAH/RAE DCV 21 21 21 21 21 21 21 21 21 21 21 21 54321SW1ON COMM TB2TB1 PPF5 1 2 4 5 J2 MARKED TERMINAL FOR10MFD CAPACITORS ONLY
  • Media type icon

    BAS-PTS036A-EN_12042024

    Document Title:Symbio™ 800 Integration Points List BACnet®/Modbus™ for IntelliCore™ Split System (RAUK)
    Publication Type:Points List
    Publication Date:2024-12-04
    Source 2 = Local Source 3 = Default Source Read Input 32011 MI-10121Electrical Service Type Indicates the electrical service type used for the unit Power Monitoring Present 1 = A+N 2 = A+B 3 = A+B+N 4 = A+B+C 5 = A+B+C+N Read Input 32016 BAS-PTS036A-EN Multi-State Inputs 18 Symbio™ 800 Integration
  • Media type icon

    12134931C_12262024

    Document Title:IPAK 1 CONTROLS SCHEMATIC 20-75T REF SYSTEM #1, EC MOTORS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-12-26
    1B 3271QA6 CONTACTOR - COMPRESSOR (CIRCUIT #1) 3571QA6 CONTACTOR - COMPRESSOR (CIRCUIT #1) 3331QA7 CONTACTOR - COMPRESSOR 1B 3541QA7 CONTACTOR - COMPRESSOR (CIRCUIT #1) 3261QA9 CONTACTOR - COMPRESSOR 2A 3521QA10 CONTACTOR - COMPRESSOR 2B 3501TA1 POWER SUPPLY - CONDENSER CONTROLS 3051XD8-1 TERMINAL
  • Media type icon

    ACC-SVN301A-EN_09152024

    access door assembly 18. Replace all the panels removed in step 2. Installation ACC-SVN301A-EN 9 19. For Through the Base Electric Connections:Customer conduit connects to the unit disconnect. Thepower wires from the disconnect are routed under theunit control box, along the outdoor section
  • Media type icon

    RT-SVX072E-EN_10122024

    7-9 1/2 18 RT-SVX072E-EN Table 2. Heating/cooling unit dimensions (ft. in.) - air-cooled - SEH_, SFH_, SSH_, SLH_, SXH_ (continued) Nom. Tons S T U V X Zw/Exh Fan w/ Ret Fan w/Exh Fan w/ Ret Fan40 7-8 3/16 3-4 5-9 5/16 3-4 3/8 3-1½ 5-7 0-5 13/16 7-9 1/2 50, 55 7-8 3/16 3-4 6-9 3/8 3-4 3/8 3-1½ 5-7
  • Media type icon

    SO-SVN031A-EN_10132023

    Document Title:RCDA - Tracer® AdaptiView™ Display Upgrade Kit RTAC Rotary Chiller
    Publication Type:Installation
    Publication Date:2023-10-13
    " MINIMUM 7/8" (USB PORT) CONTROL PANELFRONT SO-SVN031A-EN 11 Installation 4. On either the side or front control panel, drill one 7/8-inch hole for the USB Service Port. Note: Length from the USB port location to the back plate should be 18-inch or less. 5. Drill a 1-1/8-inch hole in the back of the
  • Media type icon

    PKGP-SVX015D-EN_09122025

    Document Title:Precedent™ Packaged Rooftop Units
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-09-12
    Weights 16 PKGP-SVX015D-EN Figure 6. A.0 cabinet – unit clearance and roof opening CLEARANCE 36” (914 MM) CLEARANCE 48” (1219 MM) TYPICAL ROOF OPENING CLEARANCE 36” (914 MM) CLEARANCE FROM TOP OF UNIT 72” CLEARANCEHORIZONTAL FLOW - 18” (457 MM)DOWNFLOW 36” (914 MM) 68 3/16”1732 MM 40”1016 MM 37”940 MM
  • Media type icon

    18-HE121D1-1-EN _11012017

    Document Title:Envirowise Motorized Damper for use with QF130V Ventilator
    Publication Type:Installation
    Publication Date:2017-11-01
    ENERGY LOSS AND INHIBIT MOLD GROWTH. 18-HE121D1-1-EN INSTALLATION INSTRUCTIONSCAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: MAKE SURE THE MAIN UNIT IS INSTALLED ACCORDING TO ALL INSTRUCTIONS INCLUDED WITH THE UNIT. WARNING: THIS UNIT IS TO BE USED
  • Media type icon

    12134655_B_02202023

    Document Title:IPAK2 POWER SCHEMATIC 90-150T AIRFLOW, WITH BYPASS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-20
    /RETURN FAN 386QA39 CONTACTOR - BYPASS RELIEF/RETURN FAN 426TB6 VFD RETURN/RELIEF FAN 38 700A (G/Y) 19A (O)18A (BR) 1A 2A 3A 1A 2A 3A 3L(Y) 3L 2L 2L(O) 2L 1L 1L(BR) 1L 1XP2 16A(BR) 17A(O) O 165A(BR)166A(O)167A(Y) 202BH 202BH(R) 200CU 200CU(W) BROY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22