    BAS-SVN106D-EN_05282020

    Document Title:Tracer™ AH541 Controller
    Publication Type:Installation
    Publication Date:2020-05-28
    Emission: 08/08/2003Electromagnetic Immunity: 11/18/2003 Mark of Compliance: John OlsonDesign/Compliance Engineer European contactSociete Trane (Epinal, France)1, rue des Ameriques, B.P. 6F-88191 Golbey Cedex, FrancePhone: (33) 329.31.73.00Fax: (33) 329.81.24.98 BAS-SVN106D-EN 28 May 2020Supersedes
  • Media type icon

    12134517_B_12122022

    Document Title:POWER - THREE COMPRESSORS (eSTAGE), 3/4 CONDENSER FANS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-12-12
    ÚNICAMENTE CONDUCTORES DE COBRE! LAS TERMINALES DE LA UNIDAD NO ESTÁN DISEÑADASPARA ACEPTAR OTROS TIPOS DE CONDUCTORES. SI NO LO HACE, PUEDE OCASIONAR DAÑO AL EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE SONT PAS CONÇUESPOUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. L'UTILISATION
  • Media type icon

    SOL-SVX01B-EN_04092020

    made by a qualified electrician. 18 SOL-SVX01B-EN Photovoltaic (PV) Modules Solar Panel System PV Figure 4. Self-captivating, thread cutting screw Point lances (4x) not shown Wire slot Note: The grounding clip accepts solid un-insulated copper wire sizes 10 or 12 AWG. The wire must not be nicked
  • Media type icon

    KIT02338_08012006

    Document Title:KIT02338 KIT; GASKET & O-RING, 4-8 CYL, MODEL F OPEN, NON-ASBESTOS
    Publication Type:Installation
    Publication Date:2006-08-01
    COMPRESSOR, .062 X 6.18 X 12.06, STKRAW 10/18/1999 1 Y X23040434010 GASKET; STRAINER COVER - 2.5 X 2 COMPRESSOR, .031 X 12.50 X 10.25 ID AND A STKRAW 10/18/1999 1 Y X23040439010 GASKET; .031 X 2.75 X 2.12, CHLOROPRENE (NON-ASBESTOS) W/ANTI-STICK COATING ONE STKRAW 10/18/1999 1 Y X23040437010 GASKET
  • Media type icon

    KIT02331_08012006

    Document Title:KIT02331 KIT; GASKET & O-RING, 5 & 6 CYL MODEL M, NON-ASBESTOS
    Publication Type:Installation
    Publication Date:2006-08-01
    (NON-ASBESTOS) STK RAW 12/23/1992 2 EACHX23040312010 GASKET;VALVE PLATE (NON-ASBESTOS) STK RAW 12/23/1992 3 EACH433106532100 GASKET;JUNCTION BOX STK RAW 12/23/1992 1 EACHX23040441010 GASKET; SERVICE VALVE, .031 X 1.98 X 1.50ID, CHLOROPRENE (NON-ASBESTOS), W/ANTI-STK RAW 10/18/1999 1 EACHX23040437010
  • Media type icon

    KIT03018_08012006

    Document Title:KIT03018 KIT; COMPRESSOR MOTOR CHANGEOUT,255/300 TON,STD & LONG SHELL
    Publication Type:Installation
    Publication Date:2006-08-01
    X23130322470 RING;O, 4.609 ID X .139 RD STKRA W 4/22/1996 2 PART-IN-60A LITERATURE; LOCATION OF PARTS FOR KIT03018 STKRAW 10/24/2000 1 X23130322630 RING;O, 7.234 ID X .139 RD STKRA W 12/4/1997 2 X23040440010 GASKET; SERVICE VALVE - MODEL E COMPRESSOR, .031 X 5.12 X 4.38, STKRAW 10/18/1999 2
  • Media type icon

    WSHP-PRC040B-EN_01122026

    — Control Type D = Deluxe 24V Control Digit 18 — Tstat Location 0 = Field Supplied Note: 20°F Freezestat is typically used in ageothermal application. 35°F Freezestat istypically used in a boiler/tower application. 16 WSHP-PRC040B-EN General DataTable 1. General data 5 to 20 tons Model Unit Size EXW060
  • Media type icon

    2309-2208U_05042022

    layout2 PRECAUCIÓN ATTENTION CAUTION AVERTISSEMENT ADVERTENCIAWARNING C TRANE RELEASED 04/May/2022 21:18:34 GMT AutoCAD SHX Text FAILURE TO DO SO MAY CAUSE DAMAGE TO THE AutoCAD SHX Text UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT AutoCAD SHX Text N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! AutoCAD SHX
  • Media type icon

    12134655_B_02202023

    Document Title:IPAK2 POWER SCHEMATIC 90-150T AIRFLOW, WITH BYPASS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-20
    /RETURN FAN 386QA39 CONTACTOR - BYPASS RELIEF/RETURN FAN 426TB6 VFD RETURN/RELIEF FAN 38 700A (G/Y) 19A (O)18A (BR) 1A 2A 3A 1A 2A 3A 3L(Y) 3L 2L 2L(O) 2L 1L 1L(BR) 1L 1XP2 16A(BR) 17A(O) O 165A(BR)166A(O)167A(Y) 202BH 202BH(R) 200CU 200CU(W) BROY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
  • Media type icon

    1213-4888B_08122024

    Document Title:SCHEMATIC; SHEET 1, POWER, DUAL COMPRESSOR, SINGLE CONDENSER FAN, HIGH SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-08-12
    HACE, PUEDE OCASIONAR DAÑO AL EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE SONT PAS CONÇUESPOUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. L'UTILISATION DE TOUT AUTRE CONDUCTEUR PEUTENDOMMAGER L'ÉQUIPEMENT. PRECAUCIÓNATTENTION PPF127PPM78PPF78 SPL-4 SPL-5 PPF111 PPM112 1 2