    1213-5014B_09112024

    Document Title:SCHEMATIC; SHEET 1, POWER, DUAL COMPRESSOR, DUAL CONDENSER FAN, EFLEX, 230V/460V, STD SCCR (3phase 2C)
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-11
    TYPES OF CONDUCTORS. FAILURE TO DO SO MAY CAUSE DAMAGE TO THEEQUIPMENT. CAUTION¡UTILICE ÚNICAMENTE CONDUCTORES DE COBRE! LAS TERMINALES DE LA UNIDAD NO ESTÁN DISEÑADASPARA ACEPTAR OTROS TIPOS DE CONDUCTORES. SI NO LO HACE, PUEDE OCASIONAR DAÑO AL EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE
  • Media type icon

    1213-5018B_09112024

    Document Title:SCHEMATIC; SHEET 1, POWER, DUAL COMPRESSOR, DUAL CONDENSER FAN, EFLEX, 230V/460V, HIGH SCCR (3 phase, 2c)
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-11
    DAÑO AL EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE SONT PAS CONÇUESPOUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. L'UTILISATION DE TOUT AUTRE CONDUCTEUR PEUTENDOMMAGER L'ÉQUIPEMENT. PRECAUCIÓNATTENTION 187A(BR) 188A(O) 189A(Y) PPM56 PPM85COMP-VFD-U(BR) COMP-VFD-V(O) COMP
  • Media type icon

    SRV-SVN04E-EN_08052022

    generator’s corresponding start-up guide for instructions on monitoring the voltage while adjusting. Note: Single phase power is always available on RSGPxxxxF0xx models. 18 SRV-SVN04E-EN Operation Pre-Start Procedure Before attempting to start the generator set, verify or perform these steps: 1. Fill
  • Media type icon

    2309-1913S_04282022

    Document Title:Series R® Model RTWD, RTUD, Field Wiring
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-04-28
    AutoCAD SHX Text 11 AutoCAD SHX Text 12 AutoCAD SHX Text 13 AutoCAD SHX Text 14 AutoCAD SHX Text 15 AutoCAD SHX Text 16 AutoCAD SHX Text 17 AutoCAD SHX Text 18 AutoCAD SHX Text 19 AutoCAD SHX Text 20 AutoCAD SHX Text 21 AutoCAD SHX Text 22 AutoCAD SHX Text 23 AutoCAD SHX Text 24 AutoCAD SHX Text 25
  • Media type icon

    SRV-SVX03J-EN_12122023

    Sheet and follow all recommended safe handling practices. 16 SRV-SVX03J-EN Notes SRV-SVX03J-EN 17 Notes 18 SRV-SVX03J-EN Notes SRV-SVX03J-EN 19 ©2023 Trane Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. We
  • Media type icon

    BAS-SVX082E-EN_11152025

    Document Title:E50 Series Compact Power and Energy Meters BACnet (E50H2-T2) for use with split-core and solid-core CT's
    Publication Type:Installation
    Publication Date:2025-11-15
    torque: 0.37 to 0.44 ft·lb (0.5-0.6 N·m).• Use 14 to 24 gauge (2.1 - 0.2 mm2) wire. Installation 12 BAS-SVX082E-EN Display ScreenFigure 18. Display screen buttons 00.0.0.08.8.8.8.8 Tx RxERR Screen Nameor Units Diagnostic Alert Numeric Data Alive Indicator LCD Screen Buttons (Up)Select (Right)Next (Down
  • Media type icon

    UV-PRC006D-EN_06192026

    Document Title:Vertical Classroom Unit Ventilator
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2026-06-19
    improving dehumidificationperformance of unit ventilator systems, refer to Dehumidification in HVACSystems Applications Engineering Manual (SYS-APM004*-EN). Application Considerations 18 UV-PRC006D-EN Dynamic Air Barrier Figure 12. Dynamic air barrier Unit ventila tor Capturedcold air In areas that
  • Media type icon

    AHR-PSD002B-EN_10212025

    ) Represents BK or LG(c) MCA and MOP for circuit 1 contains the motor amps Heater Attribute Data 18 AHR-PSD002B-EN Table 16. Model – 5TAMXD07AV51DB Heater Model No. No. ofCircuits 240 Volt 208 VoltCapacity Heater Amps perCircuit MinimumCircuit Ampacity MaximumOverloadProtection Capacity HeaterAmps
  • Media type icon

    FNR-PSD001A-EN_07012025

    Furnace Electrical Connections FNR-PSD001A-EN 17 Dimensional DataFigure 6. 14.5–inch, 17.5–inch, and 21–inch width cabinets 18 FNR-PSD001A-EN Notes FNR-PSD001A-EN 19 Notes Trane - by Trane Technologies (NYSE: TT), a global innovator - creates comfortable, energy efficient indoor environments
  • Media type icon

    FNR-PSD017B-EN_05292026

    Document Title:Upflow/Horizontal Left/Right Downflow Two Stage
    Publication Type:Product and Submittal Data
    Publication Date:2026-05-29
    44 42 40 39 2nd Stage 1460CFM / Watts 1420 / 377 1439 / 433 1458 / 489 1477 / 546 1496 / 602 Temp. Rise 51 50 49 49 48(a) Factory Setting Airflow Tables 18 FNR-PSD017B-EN Table 14. Heating airflow performance - model A952V080BD4S Furnace Heating Airflow (CFM), Power (Watts), and Temp. Rise (°F) vs