Search Results: 18-HE82D1-2B-EN

Showing 1,591 - 1,600 of 7,187 results

Display results per page.
  • Media type icon

    PKG-SVX029C-EN_08012025

    Dimensional Data 18 PKG-SVX029C-EN WeightsTable 6. Unit weights Unit SizeBase Weight Waterside Economizer (lbs) (lbs) 20 2763 459 25 2813 459 30 2915 459 35 2965 468 40 3423 578 45 3489 602 50 3654 626 55 3734 638 60 3904 649 65 4231 679 70 4240 777 75 4367 796 85 4466 796 90 5137 1055 100 5237 1055 110 5336
  • Media type icon

    SO-SVN025A-EN_08312023

    Document Title:Brushless DC Motor Upgrade for UniTrane Fan-Coil and Force-Flo Air Conditioners
    Publication Type:Installation
    Publication Date:2023-08-31
    Configuration Display Faster scroll through parameter name, or faster increase of values of parameters. 18 SO-SVN025A-EN Controls Configuration Configuration Settings of the ECM Engine Board Description On Unit Label User Interface Description Notes(a) NameTypical Value Mtr 1 High Spd Hi 1 1080 Sets the
  • Media type icon

    BAS-SVX087A-EN_11012020

    Document Title:Operating Guide for TR-200 E1h-E4h Drives
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-11-01
    Load Share/Regen Terminals 18 Electrical Installation 20Wiring Diagram 20 EMC-compliant Installation 20 Cabling Guidelines 23 Cable Specifications 23 Grounding Guidelines 24 Fuses 25 Contents Trane TR200 Operating Guide BAS-SVX087A-EN | 3 Trane ® 4.7 4.8 4.9 55.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10
  • Media type icon

    SO-SVN055A-EN_12092023

    vent line clearance Figure 17. Tank assembly support Figure 18. Oil tank elevated off the floor SO-SVN055A-EN 15 Compressor Replacement and Unit Assembly Chillers with Refrigerant Pump Type Oil Tank – Convert Oil Pump to R-514A Compatibility If the chiller already has a refrigerant pump type oil
  • Media type icon

    DL-SVN036A-EN_12012018

    Document Title:Split-type Air-Conditioner / Installation
    Publication Type:Installation
    Publication Date:2018-12-01
    aux exi-gences du code du bâtiment local. Manual de instalación Para el INSTALADOR• En este manual sólo se describe la instalación de la unidad exterior. Para instalar la unidad interior, consulte el manual de instalación de dicha unidad.Cualquier modificación estructural necesaria para llevar a cabo
  • Media type icon

    ACC-SVN268A-EN_12032022

    Document Title:Gas Heater Conversion
    Publication Type:Installation
    Publication Date:2022-12-03
    . Remove screws from inducer blower assembly and air orifice plate Figure 5. Remove screws from inducer blower assembly December 2022 ACC-SVN268A-EN 9 108 ©2022 Trane and American Standard have a policy of continuous product and product data improvement and reserve the right to change design and
  • Media type icon

    1213-5014B_09112024

    Document Title:SCHEMATIC; SHEET 1, POWER, DUAL COMPRESSOR, DUAL CONDENSER FAN, EFLEX, 230V/460V, STD SCCR (3phase 2C)
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-11
    TYPES OF CONDUCTORS. FAILURE TO DO SO MAY CAUSE DAMAGE TO THEEQUIPMENT. CAUTION¡UTILICE ÚNICAMENTE CONDUCTORES DE COBRE! LAS TERMINALES DE LA UNIDAD NO ESTÁN DISEÑADASPARA ACEPTAR OTROS TIPOS DE CONDUCTORES. SI NO LO HACE, PUEDE OCASIONAR DAÑO AL EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE
  • Media type icon

    1213-5018B_09112024

    Document Title:SCHEMATIC; SHEET 1, POWER, DUAL COMPRESSOR, DUAL CONDENSER FAN, EFLEX, 230V/460V, HIGH SCCR (3 phase, 2c)
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-11
    DAÑO AL EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE SONT PAS CONÇUESPOUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. L'UTILISATION DE TOUT AUTRE CONDUCTEUR PEUTENDOMMAGER L'ÉQUIPEMENT. PRECAUCIÓNATTENTION 187A(BR) 188A(O) 189A(Y) PPM56 PPM85COMP-VFD-U(BR) COMP-VFD-V(O) COMP
  • Media type icon

    ACC-SVN175F-EN_04242020

    Document Title:LonTalk® Communications Interface with ReliaTel™ Controls
    Publication Type:Installation
    Publication Date:2020-04-24
    . The input is typically sent from a supervisory controller. This input can be used for simple enable/disable functions, or can be used to enable a portion of the unit’s compressor capacity. For example, if a unit has 2 compressors, a value 18 ACC-SVN175F-EN Installation of 100 (50.0%) could indicate
  • Media type icon

    22-1809-04_02012009

    Document Title:Trane Natural Draft, Gas Fired Water Boiler with Electronic Ignition and Cast Iron Heat Exchanger
    Publication Type:Product Data
    Publication Date:2009-02-01
    With Supply Water Thermostat Setup1. No changes needed Option 1 - Factory Jumpers in PlaceNote: Boiler ships with the following jumpers in place: J1 J2 J4 J5 120 VAC Power (Field Wiring) L1 NG Circ Pump(Field Supplied) L1 NG 4 12 13 14 15 16 17 18(HV) (LV) T T19 20 L NPOWER 1 2 3 LWCO 5 6 J2(ORANGE