Search Results: TEMP-PRC013A-EN

Showing 141 - 150 of 7,172 results

Display results per page.
  • Media type icon

    SS-PRC049A-EN_08112024

    indoorfan heat. 2. kW = Total Gross Capacity, SHC = Sensible Heat Capacity Performance Data 42 SS-PRC049A-EN Table 25. Gross cooling capacities (MBH) TWA0604*A condensing unit only (IP) Outdoor Temp(°F) Saturation Suction Temperature (°F) 30 35 40 45 50 55 65 Head Press (psig) 259.1 265.4 271.9 278.8 285.8
  • Media type icon

    FNR-PSD001A-EN_07012025

    – L8V1A060U3VSL8V1A060U3VS Furnace Heating Airflow (CFM), Temp. Rise (°F), and Power (Watts) vs. External Static Pressure (iwc) with Filter Airflow Setting External Static Pressure0.1 0.3 0.5 0.7 0.9 830CFM/Watts 856/50 849/101 843/153 836/204 829/255Temp. Rise 51 51 52 52 53 FNR-PSD001A-EN 9 Table 6. Heating
  • Media type icon

    RT-PRC020-EN_02012003

    Document Title:Package Two Stage Gas - Electric Units Convertible Models YCZ036,050,060F1,3, 4, 5 Ton
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2003-02-01
    =SENSIBLE CAPACITY)TOTAL CAPACITY, COMP. KW AND APP. DEW PT.ARE VALID ONLY FOR WET COILALL TEMPERATURES IN DEGREES F. 22-1684-03-0203 (EN) 11 Performance DataCooling YCZ050F—A AT 1600 CFM(CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. TOTAL
  • Media type icon

    BAS-SVP080A-EN_08302023

    Document Title:Touch Screen Programmable Zone Sensor For Tracer® UC400–B, Symbio 400–B/500/700/800, and ReliaTel™ Controls
    Publication Type:Integration Guide
    Publication Date:2023-08-30
    installed, adjusted or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. August 2023 BAS-SVP080A-EN Integration GuideTouch
  • Media type icon

    18-SG01D1-1A-EN_03012017

    Document Title:Trane - Installer's Guide Home Standby Generator Automatic Transfer Switch
    Publication Type:Installation
    Publication Date:2017-03-01
    connected. 718-SG01D1-1A-EN SpecificationsOutside Size : 495 x 375 x 180Operation Temp -20°C to 70°C (-4°F to 158°F)Storage Temp -40°C to 85°C (-40°F to 185°F)Humidity 5 to 95% cannot freezingWeight (Kg) 17.5 Controller DKG-173 SpecificationsGenerating voltage 170-300V-AC (Ph-N phase line-null line
  • Media type icon

    RT-SVX064C-EN_04302024

    – Enabled N Circuit 2 Reversing Valve(a) Disabled – Enabled N Condenser Fan Command(a) Disabled – Enabled N OA/RA Damper Position Command 0% – 100% N 34 RT-SVX064C-EN System Configuration and Pre-Start Reports (continued from previous page) System Setpoints DAT High Temp Cutout 100°F 125°F 150°F Y
  • Media type icon

    TEMP-SLB007-EN_05122026

    Document Title:Trane Rental Services - 12 Ton Air Conditioner
    Publication Type:Sales Brochure
    Publication Date:2026-05-12
    TEMP-SLB007-EN_05122026.indd The 12-ton portable air conditioning unit offers unmatched versatility, providing powerful cooling solutions for a wide range of applications, from industrial spaces to large-scale events. Its portability and ease of setup make it ideal for temporary cooling needs
  • Media type icon

    FNR-PSD003A-EN_07012025

    Document Title:Upflow/Downflow/Horizontal Gas-Fired, 1–Stage and 2–Stage Induced Draft Furnaces with High Efficiency Motor
    Publication Type:Product and Submittal Data
    Publication Date:2025-07-01
    Upflow/Downflow/Horizontal Gas-Fired, 1–Stage and 2–Stage Induced Draft Furnaces with High Efficiency Motor July 2025 FNR-PSD003A-EN Upflow/Downflow/HorizontalGas-Fired, 1–Stage and 2–Stage Induced Draft Furnaces withHigh Efficiency MotorUpflow, Downflow, Horizontal Right/Left Single Stage Two
  • Media type icon

    BAS-SVP18E-EN_07012022

    Document Title:Tracer® UC600 Programmable Controller Packaged Outdoor Air Unit
    Publication Type:Integration Guide
    Publication Date:2022-07-01
    installed, adjusted or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. July 2022 BAS-SVP18E-EN Integration GuideTracer®
  • Media type icon

    RT-PRC115D-EN_05152026

    Document Title:Precedent™ Packaged Rooftop Units
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2026-05-15
    formula, refer to appropriate airflow table notes.2. MBh = Total gross capacity.3. SHC = Sensible heat capacity. Gross Cooling Capacities 40 RT-PRC115D-EN Table 12. Gross cooling capacities — 5 tons, standard efficiency CFMEntDB (°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) Entering Wet