    Document Title:Envirowise Dehumidifier & Ventilation System Controller D30, D30R
    Publication Type:Installation
    Publication Date:2018-05-01
    INSTALLER’S & OWNER’S MANUALHVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER Dehumidifi er & Ventilation System Controller D30D30R Part No. E4037893 18-HE110D1-1A-EN TS-994 Rev. 2 5/24/18 Table of Contents1. Specifi cations ............................................................ 22
  • Media type icon

    18-HE103D1-1A-EN_07012018

    Document Title:Envirowise 98H Whole House Ventilating Dehumidifier EDHUM098
    Publication Type:Installation
    Publication Date:2018-07-01
    right to change design and specifi cations without notice. We are committed to using environmentally conscious print practices. 18-HE103D1-1A-EN (JUL 2018)Supersedes (NEW) ©2018 Ingersoll Rand | all rights reserved
  • Media type icon

    18-HD86D1-1_08012018

    Document Title:Installation Instructions Indoor Remote Sensor/Outdoor Remote Sensor ZZSENSAL0300AA/BAYSEN30ATEMPA
    Publication Type:Installation
    Publication Date:2018-08-01
    (non-condensing)Maximum Distance from Thermostat: 300 feetRecommended Wire: 18 or 20 gauge, 3-conductor shielded cableColor: Classic WhiteDimension: 2-1/8" x 3-1/2" x 3/4" Outdoor Remote includes 12 ft. of outdoor probe lead ZZSENSAL0300AAINDOOR REMOTE SENSOR BAYSEN30ATEMPAOUTDOOR REMOTE SENSOR
  • Media type icon

    18-GJ08D1-10D-EN_12202023

    NATIONAL, STATE AND LOCAL CODES 18-GJ08D1-10D-EN Models:BAYEA1304BK1ABAYEA1304LG1ABAYEA1305BK1ABAYEA1305LG1ABAYEA1308BK1ABAYEA1308LG1A BAYEA1310BK1ABAYEA1310LG1ABAYEA1310LG3ABAYEA2315BK1ABAYEA2315LG3ABAYEA2320BK1A Table of Contents Section 1. Safety Information
  • Media type icon

    WSHP-PRC034B-EN_06302025

    Document Title:Water Source Heat Pump Axiom™ Horizontal/Vertical – EXH/EXV, DXH/DXV 0.75 to 6 Tons – 60 Hz, High Efficiency and Two-Stage High Efficiency
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-06-30
    opportunity to save energy by reducing the need to operatethe boiler or cooling tower. For example, if the water temperature stays in the desired range-between 60ºF (16ºC) and 90ºF(32ºC)-neither the boiler nor the cooling tower need to operate. 18 WSHP-PRC034B-EN In applications such as office buildings
  • Media type icon

    OAU-SVX01L-EN_06262023

    21.00 6.04 204.18 RIGHT VIEW 18 OAU-SVX01L-EN Unit Clearances, Curb Dimensions, and Dimensional Data OAN Units Unit Clearances Note: Certain options require auxiliary cabinet. Refer to project-specific unit submittals. Figure 12. Typical installation clearances for OANunit Clearance 60” Clearance 48
  • Media type icon

    5071-2778A_03242021

    Document Title:Agility - Schematic - Unit Mounted Low Votlage Air-Cooled Adaptive Frequency Drive / Enclosure Components / Wiring Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-03-24
    2T1 DRIVE MODULE CONTROL CARD FC-X02 01 02 03 04 05 06 13 33 37 (-) 3 5 (+ ) 3 6 D-O UT 2 9 D-C OM 2 0 D-IN 1 9 24 VD C 1 2 69 68 61 SERIAL PORTUSB FK100 21 3A 2X5-1 21 2B 212A 211B 21 5A 2F13 1112 24 0A 24 4A 1P1 MK100 TO 2K3-MK110 LINE 60 2F 7 5A 2F 8 20 A 203A 20 3A 20 3B ,B 2X5-2 204 G,G 20 4B
  • Media type icon

    ACC-SVN240C-EN_10042024

    Document Title:Discharge Air Sensing (DAS) Kit Precedent™ Packaged Rooftop Units
    Publication Type:Installation
    Publication Date:2024-10-04
    Installation Figure 13. FIADAST003 and FIADAST005 - Installed Figure 14. FIADAST004 and FIADAST006 - installed 18 ACC-SVN240C-EN Installation • Figure above shows FIADAST009 supply side tubing with a high-heat exchanger. • Factory downflow configuration is shown. For field-installed downflow applications
  • Media type icon

    DLR-SVX026A-EN_12132025

    Document Title:19-23 Seer 2 Single Zone Ductless Mini-Split Heat Pump
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-12-13
    18 DLR-SVX026A-EN Refrigerant SensorWARNING Leak Detection System Installed!Failure to follow instructions below could result indeath or serious injury or equipment damage.The unit is equipped with electrically powered safetymeasures and must be powered at all times afterinstallation, except during
  • Media type icon

    SS-SVN017D-EN_03142026

    capacitance between conductor and shield: < 200 pF/m• Foil or braided shield is acceptable• Wire diameter: 22 to 18 AWG SS-SVN017D-EN 17 Condenser and Air Handler PairingsTable 8. Model number descriptions TWE Air Handler with Symbio Digit 15 — Controls 1 = Constant VolumeC = 2–SpeedD = Single Zone VAV