    RTAC-SVX005B-EN_09302023

    (CSCA0200F0) Dimensions and Weights RTAC-SVX005B-EN 15 Figure 7. 200 tons RTAC (CSCA0200F2) Dimensions and Weights 16 RTAC-SVX005B-EN Figure 8. 200 tons RTAC (CSCA0200F3) Dimensions and Weights RTAC-SVX005B-EN 17 Figure 9. 250 tons RTAC (CSCA0250F0) Dimensions and Weights 18 RTAC-SVX005B-EN Figure 10. 250
  • Media type icon

    PART-SVN72C-EN_12182015

    Document Title:Location of Parts - Motor Change Out Kit, KIT16386, Model Number: CVHF / Installation Instructions
    Publication Type:Installation
    Publication Date:2015-12-18
    waste. © 2015Trane All rights reservedPART-SVN72C-EN 18 Dec 2015Supersedes PART-SVN72B-EN (08 Jun2012) 6 Table 2. Part numbers referenced in Figure 4 Part # Qty. Location and Use Ref # RNG02128 1 O-ring; suction elbow to evap 32 RNG02106 1 O-ring; volute to cond 33 GKT02694 1 Sealant; comp to suct
  • Media type icon

    DL-SVN039A-XX_11012018

    Document Title:Air Conditioners / Installation
    Publication Type:Installation
    Publication Date:2018-11-01
    -3 /813 Fente de 2-3/8 x 13/16 1-18/32 Entré e d’ air Entré e d’ air 40 840 175 500 390 330 349~ 371 Fente de 2-10 x 21 Unité: pouce Unité: mm NTXSKS18A112A✱ NTXSKS24A112A✱NTXSKS30A112A✱NTXSKS36A112A✱ VG79A981H01_FR.indd 9 2018-09-05 10:07:10 10 A B 4. Mise en place des tuyaux de réfrigérant 4.1
  • Media type icon

    1213-1533B_11082016

    Document Title:Foundation Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2016-11-08
    Engineering Change Notice PDF Export 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 WIRE COLOR DESIGNATION ABBR COLOR ABBR COLOR BK BLACK V,(PR) PURPLE BL BLUE R RED BR BROWN
  • Media type icon

    SO-SVN029A-EN_10132023

    . Connection to start signal is required. If you don’t use this contact, you need to place a wire to the start signal. 18 SO-SVN029A-EN RTHB Units with A515 (or Wye-Delta) Starters Figure 17. Power wiring (new wiring bold/highlighted in red) — RTHB To TB3 - CT1 on Benshaw SSS module To TB3 - CT3 on Benshaw
  • Media type icon

    CLCH-SVN006D-EN_04292020

    Document Title:Roof Curbs for Performance Climate Changer Air Handler Model UCCA for Outdoor Applications Sizes 3-30
    Publication Type:Installation
    Publication Date:2020-04-29
    59.07 83.2021 59.07 83.2025 61.77 85.9030 68.37 92.50 10 CLCH-SVN006D-EN Assembly and Installation Specialty Roof Curbs Units to be mounted on a roof curb not supplied by Trane require special attention. Center the unit base on the roof curb (see Figure 18). Figure 18. Typical cross section for pier
  • Media type icon

    2311-1976C_03092022

    APPLICABLE CODES. ALL CUSTOMER CONTROL CIRCUIT WIRING MUST BE COPPER CONDUCTORS ONLY AND HAVE A MINIMUM INSULATION RATING OF 300 VOLTS.EXCEPT AS NOTED ALL CUSTOMER WIRING CONNECTIONS ARE MADE TO CIRCUIT BOARD MOUNTED BOX LUGS WITH A WIRE RANGE OF 14TO 18 AWG. DO NOT RUN LOW VOLTAGE CONTROL WIRING (30 VOLTS
  • Media type icon

    FIN-PRC011B-EN_04242020

    Document Title:Electric Wall FIN Architectural Convectors
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2020-04-24
    /DBT is not suitable or ETL listed for residential applications. 18 FIN-PRC011B-EN Mechanical Specifications and Dimensions Dimensions Figure 5. DBF-DBT architectural pedestal heaters 2.0”(50.8 mm) 2.0”(50.8 mm) (609.6 mm Thru 3048 mm)2 FT THRU 10FT LENGTHS (609.6 mm Thru 3048 mm)2 FT THRU 10FT LENGTHS
  • Media type icon

    ACC-SVN270B-EN_08232024

    Document Title:Low Ambient Control — Foundation™ Packaged Rooftop Units 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    August 2024 ACC-SVN270B-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed
  • Media type icon

    18-GJ80D1-1-EN_03012017

    Document Title:Installer's Guide Hydronic Heater Relay Kit BAYWAKIT24VACA For use with communicating TAM9 air handlers with BAYWA hydronic heaters
    Publication Type:Installation
    Publication Date:2017-03-01
    this installation must comply with NATIONAL, STATE AND LOCAL CODES 18-GJ80D1-1-EN 03/17 Model:BAYWAKIT24VACA Section 1. General InformationThe BAYWAKIT24VACA kit includes a wire harness and relay. The kit is for use with the TAM9 air handler when using a BAYWA 05, 07, 08, and 11 hydronic heating coil