Search Results: ED*

Showing 1,061 - 1,070 of 1,420 results

Display results per page.
  • Media type icon

    RT-SVX069F-EN_08232024

    and install the roof curb (if applicable). Referto the latest edition of the curb installers guide thatships with each curb kit. 16 RT-SVX069F-EN ☐ Fabricate and install ductwork; secure ductwork tocurb. ☐ Rigging the unit.☐ Set the unit onto the curb; check for levelness.☐ Ensure unit-to-curb seal
  • Media type icon

    RT-SVN037A-EN_05282021

    Document Title:Roof Curb For Medium Foundation Packaged Rooftops 7.5 – 12.5 Tons
    Publication Type:Installation
    Publication Date:2021-05-28
    . IImmppoorrttaanntt:: Duct work must be hung from the curbflanges. It must not be installed over thetop edges of the curb. • When the duct is fabricated it should be largeenough to cover the openings for the return andsupply sides of the unit, but the flanges must benarrow enough to slide down inside the
  • Media type icon

    RLC-PRC020M-EN_06012025

    CONDENSER OIL SUMP Dimensions and Weights RLC-PRC020M-EN 25 Figure 3. CDE, DDE, EDE configurations 73.44 [1865 mm] 6.00 [153 mm] 14.38 [366 mm] 67.88 [1723 mm] 12.49 [317 mm] 14.13 [359 mm] COND EVAP OUT IN IN 25.88 [657 mm] OUT EVAPORATOR IN 9.60 [230 mm] 14.88 [378 mm] 107.63 [2734 mm]Standard 3
  • Media type icon

    TF-SVX006A-EN_06152025

    Document Title:Thermafit™ Modular Air-to-Water Heat Pump - Model AXM
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-06-15
    bereported to the owner of the equipment, so all parties areadvised.Initial safety checks shall include:• Cabling is not subject to wear, corrosion, excessive pressure, vibration, sharp edges, or any other adverseenvironmental effects. Account for the effects of agingor continual vibration from sources such
  • Media type icon

    CLCH-SVX020A-EN_07132025

    -center spacing. • Install clips at single level ship splits containing fans orcoils at 48 inches maximum on-center spacing. • 3 1/4-inch minimum anchor embedment.• 71/2-inch minimum distance to the nearest edge.• 6-inch minimum concrete slab thickness. Steel Dunnage/Steel Curb:1/2-inch diameter ASTM
  • Media type icon

    DCRB-WPR002B-EN_06192025

    Document Title:What's Driving High-Performance Buildings - 5 ELECTRIFIED HEATING TRENDS
    Publication Type:White Paper
    Publication Date:2025-06-19
    cutting-edge efficient technology to extend the operating range for electrified heating beyond the limits of conventional heat pump systems. See the first-ever Thermal Battery Storage-Source Heat Pump System. ▶ COP of 3 on cold mornings, even when its below 0°F (-18°C) ▶ 3 times higher COP than
  • Media type icon

    APP-PRC010B-EN_04012025

    encapsulated insulation edges and access panels• Optional electronically commutated motor (ECM) and modulating airflow control algorithms• Optional Suppressor induction air inlet sound attenuator• Optional LEED wrap for preventing contamination during the construction phase• Optional factory mounted, wired
  • Media type icon

    UNT-SVX07Q-EN_06302025

    that all wires are plugged in securely.☐ Ensure that edge protection on sharp edges, grommets, and wire management devices aremaintained when replacing components. ☐ Ensure that blunt-tip screws are used when in theproximity of wire harnesses. Circuit Module Replacement1. Circuit modules are equipped
  • Media type icon

    WSHP-SVX018D-EN_06302025

    subject to wear, corrosion, excessivepressure, vibration, sharp edges, or any other adverseenvironmental effects. Account for the effects of agingor continual vibration from sources such ascompressors or fans. • Capacitors are discharged. This shall be done in a safemanner to avoid possibility of
  • Media type icon

    WSHP-PRC033B-EN_06302025

    Document Title:Water Source Heat Pump Axiom™ Horizontal/Vertical – GEH/GEV* 0.5 to 25 Tons – 50/60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-06-30
    Access PanelsThe upper panels of the GEV 12.5 to 25 ton units feature a key holehanging design for ease of maintenance of the unit, allowing the panel tobe hooked into place when attaching the panel to the unit. The panels arealso sealed with a rubber gasket at all four edges to help eliminate air